1.
Appl Radiat Isot ; 70(7): 1121-4, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22365111

RESUMO

Silicon diodes with large aspect ratio 3D microstructures backfilled with 6LiF show a significant increase in neutron detection efficiency beyond that of conventional thin-film coated planar devices. Described in this work are advancements in the technology using detector stacking methods and summed-detector 6×6-element arraying methods to dramatically increase the sensitivity to thermal neutrons. The intrinsic detection efficiency of the 6×6 array for normal-incident 0.0253 eV neutrons was found 6.8% compared against a calibrated 3He proportional counter.

2.
Appl Radiat Isot ; 70(7): 1118-20, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22236603

RESUMO

A CdZnTe electro-optic radiation detector was used to calibrate nuclear reactor pulses. The standard configuration of the Pockels cell has collimated light passing through an optically transparent CdZnTe crystal located between crossed polarizers. The transmitted light was focused onto an IR sensitive photodiode. Calibrations of reactor pulses were performed using the CdZnTe Pockels cell by measuring the change in the photodiode current, repeated 10 times for each set of reactor pulses, set between 1.00 and 2.50 dollars in 0.50 increments of reactivity.