1.
Vet Clin Pathol ; 48 Suppl 1: 70-77, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31310344

RESUMO

BACKGROUND: Cardiac troponin I (cTnI) is a sensitive and specific biomarker for myocardial injury. Validation of point-of-care (POC) analyzers for cTnI measurement is valuable to the critical care setting, in which rapid results can facilitate prompt diagnoses. An immunoassay for detecting cTnI is available for the POC AIA-360 analyzer (Tosoh Bioscience), but this has not been validated using canine and feline serum. OBJECTIVES: The objectives were (a) to determine precision, accuracy, and linearity of cTnI measurement using the AIA-360 immunoassay in pooled canine and feline samples, and (b) to compare results for individual canine and feline samples with those obtained using a reference chemiluminescence method (Immulite 1000, Siemens). METHODS: Intra- and inter-assay repeatability was determined using pooled canine and feline samples, and the coefficient of variation (CV) was calculated for each. Pooled samples were also serially diluted to assess linearity. A modified spike and recovery analysis was performed by mixing pooled samples with different concentrations. Bland-Altman and Deming regression analyses were used to determine bias for individual samples, and the total observed error (TEobs ) was calculated. RESULTS: Coefficient of variation values were well within the required maximum of 20%. Linearity was demonstrated over the range of samples tested, and the recovery study showed minimal proportional inaccuracies. Although the correlation between the analyzers was excellent, there was a large mean bias due to relative proportional bias. Total observed error consequently exceeded the total allowable error (TEA ). CONCLUSION: Although, in most respects, the analyzer demonstrated adequate performance, pronounced bias contributed to the large TEobs , indicating a requirement for analyzer-specific reference intervals.


Assuntos
Imunoensaio/veterinária , Sistemas Automatizados de Assistência Junto ao Leito/normas , Troponina I/sangue , Animais , Biomarcadores/sangue , Gatos , Cães , Imunoensaio/normas , Valores de Referência , Reprodutibilidade dos Testes
2.
J Vet Diagn Invest ; 31(2): 164-174, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30638139

RESUMO

Serum cobalamin and folate are often measured in cats and dogs as part of laboratory testing for intestinal disease, small intestinal dysbiosis, or exocrine pancreatic deficiency. We performed an analytical validation of human immunoassays for cobalamin and folate measurement (AIA-900 analyzer, Tosoh Bioscience) and compared results with those obtained using chemiluminescence assays (Immulite 2000 analyzer, Siemens Medical Solutions Diagnostics). Accuracy, precision, total observable error (TEobs%), and σ values were calculated for the immunoassays. Correlation and agreement were evaluated with Deming regression, Passing-Bablok regression, and Bland-Altman analysis. Cobalamin intra-assay and inter-assay CVs were 1.8-9.3% and 2.6-6.8%, respectively. Folate intra-assay and inter-assay CVs were 1.5-9.1% and 3.4-8.1%, respectively. TEobs (%) were ≤19 and ≤31 for cobalamin and folate, respectively. Sigma values were 3.60-11.50 for cobalamin and 2.90-7.50 for folate. Regression analysis demonstrated very high or high correlations for cobalamin [ r = 0.98 (dogs), 0.97 (cats)] and folate [ r = 0.88 (dogs), 0.92 (cats)] but Bland-Altman analysis revealed poor agreement for both. The immunoassays had good analytical performance for measuring cobalamin and folate in both species. Results obtained by the 2 analyzers cannot be used interchangeably and should be interpreted using instrument-specific reference intervals. Further studies are required to establish immunoassay-specific reference intervals and to evaluate the diagnostic performance and clinical utility of the analyzer for these analytes.


Assuntos
Gatos/sangue , Cães/sangue , Ácido Fólico/sangue , Imunoensaio/veterinária , Vitamina B 12/sangue , Animais , Humanos , Imunoensaio/métodos , Medições Luminescentes , Valores de Referência