Bone Joint J ; 96-B(10): 1298-306, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25274912

RESUMO

We report a 12- to 15-year implant survival assessment of a prospective single-surgeon series of Birmingham Hip Resurfacings (BHRs). The earliest 1000 consecutive BHRs including 288 women (335 hips) and 598 men (665 hips) of all ages and diagnoses with no exclusions were prospectively followed-up with postal questionnaires, of whom the first 402 BHRs (350 patients) also had clinical and radiological review. Mean follow-up was 13.7 years (12.3 to 15.3). In total, 59 patients (68 hips) died 0.7 to 12.6 years following surgery from unrelated causes. There were 38 revisions, 0.1 to 13.9 years (median 8.7) following operation, including 17 femoral failures (1.7%) and seven each of infections, soft-tissue reactions and other causes. With revision for any reason as the end-point Kaplan-Meier survival analysis showed 97.4% (95% confidence interval (CI) 96.9 to 97.9) and 95.8% (95% CI 95.1 to 96.5) survival at ten and 15 years, respectively. Radiological assessment showed 11 (3.5%) femoral and 13 (4.1%) acetabular radiolucencies which were not deemed failures and one radiological femoral failure (0.3%). Our study shows that the performance of the BHR continues to be good at 12- to 15-year follow-up. Men have better implant survival (98.0%; 95% CI 97.4 to 98.6) at 15 years than women (91.5%; 95% CI 89.8 to 93.2), and women < 60 years (90.5%; 95% CI 88.3 to 92.7) fare worse than others. Hip dysplasia and osteonecrosis are risk factors for failure. Patients under 50 years with osteoarthritis fare best (99.4%; 95% CI 98.8 to 100 survival at 15 years), with no failures in men in this group.


Assuntos
Artroplastia de Quadril/métodos , Previsões , Articulação do Quadril/fisiopatologia , Prótese de Quadril , Osteoartrite do Quadril/cirurgia , Amplitude de Movimento Articular/fisiologia , Recuperação de Função Fisiológica , Adulto , Idoso , Artroplastia de Quadril/efeitos adversos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Reoperação/métodos , Resultado do Tratamento
4.
BMJ ; 344: e3319, 2012 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-22700782

RESUMO

OBJECTIVES: To examine mortality and revision rates among patients with osteoarthritis undergoing hip arthroplasty and to compare these rates between patients undergoing cemented or uncemented procedures and to compare outcomes between men undergoing stemmed total hip replacements and Birmingham hip resurfacing. DESIGN: Cohort study. SETTING: National Joint Registry. POPULATION: About 275,000 patient records. MAIN OUTCOME MEASURES: Hip arthroplasty procedures were linked to the time to any subsequent mortality or revision (implant failure). Flexible parametric survival analysis methods were used to analyse time to mortality and also time to revision. Comparisons between procedure groups were adjusted for age, sex, American Society of Anesthesiologists (ASA) grade, and complexity. RESULTS: As there were large baseline differences in the characteristics of patients receiving cemented, uncemented, or resurfacing procedures, unadjusted comparisons are inappropriate. Multivariable survival analyses identified a higher mortality rate for patients undergoing cemented compared with uncemented total hip replacement (adjusted hazard ratio 1.11, 95% confidence interval 1.07 to 1.16); conversely, there was a lower revision rate with cemented procedures (0.53, 0.50 to 0.57). These translate to small predicted differences in population averaged absolute survival probability at all time points. For example, compared with the uncemented group, at eight years after surgery the predicted probability of death in the cemented group was 0.013 higher (0.007 to 0.019) and the predicted probability of revision was 0.015 lower (0.012 to 0.017). In multivariable analyses restricted to men, there was a higher mortality rate in the cemented group and the uncemented group compared with the Birmingham hip resurfacing group. In terms of revision, the Birmingham hip resurfacings had a similar revision rate to uncemented total hip replacements. Both uncemented total hip replacements and Birmingham hip resurfacings had a higher revision rate than cemented total hip replacements. CONCLUSIONS: There is a small but significant increased risk of revision with uncemented rather than cemented total hip replacement, and a small but significant increased risk of death with cemented procedures. It is not known whether these are causal relations or caused by residual confounding. Compared with uncemented and cemented total hip replacements, Birmingham hip resurfacing has a significantly lower risk of death in men of all ages. Previously, only adjusted analyses of hip implant revision rates have been used to recommend and justify use of cheaper cemented total hip implants. Our investigations additionally consider mortality rates and suggest a potentially higher mortality rate with cemented total hip replacements, which merits further investigation.


Assuntos
Artroplastia de Quadril/métodos , Osteoartrite do Quadril/mortalidade , Osteoartrite do Quadril/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Cimentação/mortalidade , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Falha de Prótese , Sistema de Registros , Reoperação/estatística & dados numéricos , Análise de Sobrevida , Adulto Jovem
5.
Int Orthop ; 35(2): 231-7, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21079954

RESUMO

The best indication for hip resurfacing is a young active patient with severe hip arthritis, good hip morphology and reasonable bone quality. With revision of either component for any reason as the endpoint, there were 68 revisions in our series of 3,095 consecutive Birmingham Hip Resurfacings (BHR) (1997-2009), including all diagnoses in all ages. This equates to a revision rate of 2.2% and survivorships of 99, 97 and 96% at five, ten and 13 years, respectively. In patients under 55 years with osteoarthritis, the survivorship is 99 and 98% at ten and 13 years. These results provide medium-term evidence that BHR when performed well in properly selected patients offers excellent outcomes and implant survivorship. Small changes to implant materials and design can affect joint function and survivorship significantly as seen from the withdrawal of certain resurfacing devices recently from clinical use. The clinical history of one device cannot be extrapolated to other devices.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Desenho de Prótese , Falha de Prótese/etiologia , Adolescente , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/cirurgia , Reoperação , Fatores de Risco , Adulto Jovem
6.
J Bone Joint Surg Br ; 92(5): 717-25, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20436012

RESUMO

Hip simulators have been used for ten years to determine the tribological performance of large-head metal-on-metal devices using traditional test conditions. However, the hip simulator protocols were originally developed to test metal-on-polyethylene devices. We have used patient activity data to develop a more physiologically relevant test protocol for metal-on-metal devices. This includes stop/start motion, a more appropriate walking frequency, and alternating kinetic and kinematic profiles. There has been considerable discussion about the effect of heat treatments on the wear of metal-on-metal cobalt chromium molybdenum (CoCrMo) devices. Clinical studies have shown a higher rate of wear, levels of metal ions and rates of failure for the heat-treated metal compared to the as-cast metal CoCrMo devices. However, hip simulator studies in vitro under traditional testing conditions have thus far not been able to demonstrate a difference between the wear performance of these implants. Using a physiologically relevant test protocol, we have shown that heat treatment of metal-on-metal CoCrMo devices adversely affects their wear performance and generates significantly higher wear rates and levels of metal ions than in as-cast metal implants.


Assuntos
Ligas de Cromo/química , Prótese de Quadril , Teste de Materiais/métodos , Idoso , Artroplastia de Quadril/efeitos adversos , Materiais Biocompatíveis , Fenômenos Biomecânicos , Estudos Transversais , Temperatura Alta , Humanos , Lubrificantes/química , Masculino , Metalurgia/métodos , Pessoa de Meia-Idade , Modelos Biológicos , Osteólise/etiologia , Polietileno , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Propriedades de Superfície , Caminhada/fisiologia , Caminhada/estatística & dados numéricos
7.
J Bone Joint Surg Br ; 92(1): 20-7, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20044674

RESUMO

Second-generation metal-on-metal bearings were introduced as a response to the considerable incidence of wear-induced failures associated with conventional replacements, especially in young patients. We present the results at ten years of a consecutive series of patients treated using a metal-on-metal hip resurfacing. A distinct feature of the bearings used in our series was that they had been subjected to double-heat treatments during the post-casting phase of their manufacture. In the past these bearings had not been subjected to thermal treatments, making this a unique metal-on-metal bearing which had not been used before in clinical practice. We report the outcome of 184 consecutive hips (160 patients) treated using a hybrid-fixed metal-on-metal hip resurfacing during 1996. Patients were invited for a clinicoradiological follow-up at a minimum of ten years. The Oxford hip score and anteroposterior and lateral radiographs were obtained. The mean age at operation was 54 years (21 to 75). A series of 107 consecutive hips (99 patients) who received the same prosthesis, but subjected to a single thermal treatment after being cast, between March 1994 and December 1995, were used as a control group for comparison. In the 1994 to 1995 group seven patients (seven hips) died from unrelated causes and there were four revisions (4%) for osteolysis and aseptic loosening. In the 1996 group nine patients died at a mean of 6.9 years after operation because of unrelated causes. There were 30 revisions (16%) at a mean of 7.3 years (1.2 to 10.9), one for infection at 1.2 years and 29 for osteolysis and aseptic loosening. Furthermore, in the latter group there were radiological signs of failure in 27 (24%) of the 111 surviving hips. The magnitude of the problem of osteolysis and aseptic loosening in the 1996 cohort did not become obvious until five years after the operation. Our results indicate that double-heat treatments of metal-on-metal bearings can lead to an increased incidence of wear-induced osteolysis.


Assuntos
Ligas de Cromo , Prótese de Quadril , Osteólise/etiologia , Desenho de Prótese , Adulto , Idoso , Artroplastia de Quadril/instrumentação , Causas de Morte , Análise de Falha de Equipamento , Feminino , Seguimentos , Temperatura Alta , Humanos , Masculino , Pessoa de Meia-Idade , Osteólise/diagnóstico por imagem , Falha de Prótese , Radiografia , Análise de Sobrevida , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
8.
J Bone Joint Surg Br ; 91(2): 176-9, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19190049

RESUMO

We describe the findings at six years in an ongoing prospective clinicoradiological and metal ion study in a cohort of 26 consecutive male patients with unilateral Birmingham Hip Resurfacing arthroplasties with one of two femoral head sizes (50 mm and 54 mm). Their mean age was 52.9 years (29 to 67). We have previously shown an early increase in the 24-hour urinary excretion of metal ions, reaching a peak at six months (cobalt) and one year (chromium) after operation. Subsequently there is a decreasing trend in excretion of both cobalt and chromium. The levels of cobalt and chromium in whole blood also show a significant increase at one year, followed by a decreasing trend until the sixth year.


Assuntos
Artroplastia de Quadril , Cromo/análise , Cobalto/análise , Cobalto/metabolismo , Cabeça do Fêmur , Prótese de Quadril/efeitos adversos , Adulto , Idoso , Cromo/sangue , Cromo/urina , Cobalto/sangue , Cobalto/urina , Métodos Epidemiológicos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Fatores de Tempo , Resultado do Tratamento
9.
J Bone Joint Surg Br ; 90(6): 715-23, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18539663

RESUMO

The dysplasia cup, which was devised as an adjunct to the Birmingham Hip Resurfacing system, has a hydroxyapatite-coated porous surface and two supplementary neutralisation screws to provide stable primary fixation, permit early weight-bearing, and allow incorporation of morcellised autograft without the need for structural bone grafting. A total of 110 consecutive dysplasia resurfacing arthroplasties in 103 patients (55 men and 48 women) performed between 1997 and 2000 was reviewed with a minimum follow-up of six years. The mean age at operation was 47.2 years (21 to 62) and 104 hips (94%) were Crowe grade II or III. During the mean follow-up of 7.8 years (6 to 9.6), three hips (2.7%) were converted to a total hip replacement at a mean of 3.9 years (2 months to 8.1 years), giving a cumulative survival of 95.2% at nine years (95% confidence interval 89 to 100). The revisions were due to a fracture of the femoral neck, a collapse of the femoral head and a deep infection. There was no aseptic loosening or osteolysis of the acetabular component associated with either of the revisions performed for failure of the femoral component. No patient is awaiting a revision. The median Oxford hip score in 98 patients with surviving hips at the final review was 13 and the 10th and the 90th percentiles were 12 and 23, respectively.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Luxação Congênita de Quadril/cirurgia , Acetábulo/diagnóstico por imagem , Adulto , Feminino , Seguimentos , Luxação Congênita de Quadril/complicações , Luxação Congênita de Quadril/diagnóstico por imagem , Prótese de Quadril , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/diagnóstico por imagem , Osteoartrite do Quadril/etiologia , Desenho de Prótese , Radiografia , Índice de Gravidade de Doença , Análise de Sobrevida , Resultado do Tratamento
10.
J Bone Joint Surg Br ; 90(5): 562-9, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18450619

RESUMO

We report a retrospective review of the incidence of venous thromboembolism in 463 consecutive patients who underwent primary total hip arthroplasty (487 procedures). Treatment included both total hip replacement and hip resurfacing, and the patients were managed without anticoagulants. The thromboprophylaxis regimen included an antiplatelet agent, generally aspirin, hypotensive epidural anaesthesia, elastic compression stockings and early mobilisation. In 258 of these procedures (244 patients) performed in 2005 (cohort A) mechanical compression devices were not used, whereas in 229 (219 patients) performed during 2006 (cohort B) bilateral intermittent pneumatic calf compression was used. All operations were performed through a posterior mini-incision approach. Patients who required anticoagulation for pre-existing medical problems and those undergoing revision arthroplasty were excluded. Doppler ultrasonographic screening for deep-vein thrombosis was performed in all patients between the fourth and sixth post-operative days. All patients were reviewed at a follow-up clinic six to ten weeks after the operation. In addition, response to a questionnaire was obtained at the end of 12 weeks post-operatively. No symptomatic calf or above-knee deep-vein thrombosis or pulmonary embolism occurred. In 25 patients in cohort A (10.2%) and in ten patients in cohort B (4.6%) asymptomatic calf deep-vein thromboses were detected ultrasonographically. This difference was statistically significant (p = 0.03). The regimen followed by cohort B offers the prospect of a low incidence of venous thromboembolism without subjecting patients to the higher risk of bleeding associated with anticoagulant use.


Assuntos
Artroplastia de Quadril/efeitos adversos , Deambulação Precoce/métodos , Inibidores da Agregação Plaquetária/uso terapêutico , Complicações Pós-Operatórias/prevenção & controle , Meias de Compressão , Tromboembolia Venosa/prevenção & controle , Adulto , Idoso , Idoso de 80 Anos ou mais , Aspirina/uso terapêutico , Métodos Epidemiológicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
11.
J Bone Joint Surg Br ; 89(9): 1140-3, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17905947

RESUMO

The early designs of hip resurfacing implants suffered high rates of early failure, making it impossible to obtain valuable mid-term radiostereophotogrammetric (RSA) results. The metal-on-metal Birmingham Hip Resurfacing arthroplasty has shown promising mid-term results and we present here the first mid-term RSA analysis of a hip resurfacing implant. The analysis was performed in 19 hips at five years post-operatively. The mean acetabular component translation and rotation, and femoral component translation were compared with the previous RSA measurements at two and six months, and one and two years. There was no statistical significance (t-test, p < or = 0.05) between these consecutive movements, indicating the mid-term stability of the implant.


Assuntos
Artroplastia de Quadril/métodos , Articulação do Quadril/diagnóstico por imagem , Prótese de Quadril , Complicações Pós-Operatórias/diagnóstico por imagem , Artroplastia de Quadril/normas , Seguimentos , Articulação do Quadril/fisiopatologia , Prótese de Quadril/normas , Humanos , Masculino , Falha de Prótese , Radiografia , Rotação
12.
J Bone Joint Surg Br ; 89(6): 736-41, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17613496

RESUMO

Metal ions generated from joint replacements are a cause for concern. There is no consensus on the best surrogate measure of metal ion exposure. This study investigates whether serum and whole blood concentrations can be used interchangeably to report results of cobalt and chromium ion concentrations. Concentrations of serum and whole blood were analysed in 262 concurrent specimens using high resolution inductively-coupled plasma mass-spectrometry. The agreement was assessed with normalised scatterplots, mean difference and the Bland and Altman limits of agreement. The wide variability seen in the normalised scatterplots, in the Bland and Altman plots and the statistically significant mean differences between serum and whole blood concentrations suggest that they cannot be used interchangeably. A bias was demonstrated for both ions in the Bland-Altman plots. Regression analysis provided a possible conversion factor of 0.71 for cobalt and 0.48 for chromium. However, even when the correction factors were applied, the limits of agreement were greater than +/-67% for cobalt and greater than +/-85% for chromium, suggesting that serum and whole blood cannot be used interconvertibly. This suggests that serum metal concentrations are not useful as a surrogate measure of systemic metal ion exposure.


Assuntos
Artroplastia de Quadril/efeitos adversos , Cromo/sangue , Cobalto/sangue , Prótese de Quadril/efeitos adversos , Adulto , Idoso , Cromo/efeitos adversos , Cobalto/efeitos adversos , Métodos Epidemiológicos , Feminino , Humanos , Íons/sangue , Masculino , Pessoa de Meia-Idade
13.
J Bone Joint Surg Br ; 89(3): 301-5, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17356138

RESUMO

Metal-on-metal bearings are being increasingly used in young patients. The potential adverse effects of systemic metal ion elevation are the subject of ongoing investigation. The purpose of this study was to investigate whether cobalt and chromium ions cross the placenta of pregnant women with a metal-on-metal hip resurfacing and reach the developing fetus. Whole blood levels were estimated using high-resolution inductively-coupled plasma mass spectrometry. Our findings showed that cobalt and chromium are able to cross the placenta in the study patients with metal-on-metal hip resurfacings and in control subjects without any metal implants. In the study group the mean concentrations of cobalt and chromium in the maternal blood were 1.39 microg/l (0.55 to 2.55) and 1.28 microg/l (0.52 to 2.39), respectively. The mean umbilical cord blood concentrations of cobalt and chromium were comparatively lower, at 0.839 microg/l (0.42 to 1.75) and 0.378 microg/l (0.14 to 1.03), respectively, and this difference was significant with respect to chromium (p < 0.05). In the control group, the mean concentrations of cobalt and chromium in the maternal blood were 0.341 microg/l (0.18 to 0.54) and 0.199 microg/l (0.12 to 0.33), and in the umbilical cord blood they were 0.336 microg/l (0.17 to 0.5) and 0.194 microg/l (0.11 to 0.56), respectively. The differences between the maternal and umbilical cord blood levels in the controls were marginal, and not statistically significant (p > 0.05). The mean cord blood level of cobalt in the study patients was significantly greater than that in the control group (p < 0.01). Although the mean umbilical cord blood chromium level was nearly twice as high in the study patients (0.378 microg/l) as in the controls (0.1934 microg/l), this difference was not statistically significant. (p > 0.05) The transplacental transfer rate was in excess of 95% in the controls for both metals, but only 29% for chromium and 60% for cobalt in study patients, suggesting that the placenta exerts a modulatory effect on the rate of metal ion transfer.


Assuntos
Artroplastia de Quadril/efeitos adversos , Cromo/sangue , Cobalto/sangue , Prótese de Quadril , Troca Materno-Fetal/fisiologia , Adulto , Estudos de Casos e Controles , Feminino , Sangue Fetal/química , Humanos , Espectrometria de Massas/métodos , Gravidez , Estudos Prospectivos , Desenho de Prótese
14.
J Bone Joint Surg Br ; 89(2): 169-73, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17322429

RESUMO

This is a longitudinal study of the daily urinary output and the concentrations in whole blood of cobalt and chromium in patients with metal-on-metal resurfacings over a period of four years. Twelve-hour urine collections and whole blood specimens were collected before and periodically after a Birmingham hip resurfacing in 26 patients. All ion analyses were carried out using a high-resolution inductively-coupled plasma mass spectrometer. Clinical and radiological assessment, hip function scoring and activity level assessment revealed excellent hip function. There was a significant early increase in urinary metal output, reaching a peak at six months for cobalt and one year for chromium post-operatively. There was thereafter a steady decrease in the median urinary output of cobalt over the following three years, although the differences are not statistically significant. The mean whole blood levels of cobalt and chromium also showed a significant increase between the pre-operative and one-year post-operative periods. The blood levels then decreased to a lower level at four years, compared with the one-year levels. This late reduction was statistically significant for chromium but not for cobalt. The effects of systemic metal ion exposure in patients with metal-on-metal resurfacing arthroplasties continue to be a matter of concern. The levels in this study provide a baseline against which the in vivo wear performance of newer bearings can be compared.


Assuntos
Artroplastia de Quadril/métodos , Metais/sangue , Metais/urina , Adulto , Idoso , Cromo/sangue , Cromo/urina , Cobalto/sangue , Cobalto/urina , Seguimentos , Prótese de Quadril , Humanos , Pessoa de Meia-Idade , Período Pós-Operatório , Estudos Prospectivos , Falha de Prótese , Manejo de Espécimes/métodos
15.
J Bone Joint Surg Br ; 88(4): 443-8, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16567776

RESUMO

The recent resurgence in the use of metal-on-metal bearings has led to fresh concerns over metal wear and elevated systemic levels of metal ions. In order to establish if bearing diameter influences the release of metal ions, we compared the whole blood levels of cobalt and chromium (at one year) and the urinary cobalt and chromium output (at one to three and four to six years) following either a 50 mm or 54 mm Birmingham hip resurfacing or a 28 mm Metasul total hip replacement. The whole blood concentrations and daily output of cobalt and chromium in these time periods for both bearings were in the same range and without significant difference.


Assuntos
Cromo/análise , Cobalto/análise , Prótese de Quadril , Adulto , Idoso , Cromo/sangue , Cromo/urina , Cobalto/sangue , Cobalto/urina , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Humanos , Pessoa de Meia-Idade , Desenho de Prótese , Radiografia , Fatores de Tempo
16.
J Bone Joint Surg Br ; 86(2): 177-84, 2004 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15046429

RESUMO

The results of conventional hip replacement in young patients with osteoarthritis have not been encouraging even with improvements in the techniques of fixation and in the bearing surfaces. Modern metal-on-metal hip resurfacing was introduced as a less invasive method of joint reconstruction for this particular group. This is a series of 446 hip resurfacings (384 patients) performed by one of the authors (DJWM) using cemented femoral components and hydroxyapatite-coated uncemented acetabular components with a maximum follow-up of 8.2 years (mean 3.3). Their survival rate, Oxford hip scores and activity levels are reviewed. Six patients died due to unrelated causes. There was one revision (0.02%) out of 440 hips. The mean Oxford score of the surviving 439 hips is 13.5. None of the patients were told to change their activities at work or leisure; 31% of the men with unilateral resurfacings and 28% with bilateral resurfacings were involved in jobs that they considered heavy or moderately heavy; 92% of men with unilateral hip resurfacings and 87% of the whole group participate in leisure-time sporting activity. The extremely low rate of failure in spite of the resumption of high level occupational and leisure activities provides early evidence of the suitability of this procedure for young and active patients with arthritis.


Assuntos
Artroplastia de Quadril/métodos , Prótese de Quadril , Osteoartrite do Quadril/cirurgia , Adulto , Fatores Etários , Feminino , Seguimentos , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Osteoartrite do Quadril/diagnóstico por imagem , Desenho de Prótese , Falha de Prótese , Radiografia , Análise de Sobrevida
17.
Hip Int ; 13(1): 41-53, 2003 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-24030583

RESUMO

This author's development of metal/metal hip resurfacing began in 1989, with the first patient implantation in February 1991. In the first three years a pilot study identified optimum fixation as hydroxyapatite coated uncemented cups and cemented femoral components. From March 1994 hybrid fixed components have been used. These implants have generally been satisfactory with respect to fixation but high wear of the bearing, metallosis and osteolysis have been seen with some components inserted during 1996, a period during which the metal microstructure was altered by the heat processes, hot isostatic pressing and solution heat treatment. The Birmingham Hip Resurfacing was developed taking account of experience with earlier resurfacing designs. This implant employs hybrid fixation with a porous ingrowth acetabular component and has an as-cast metal microstructure having had no post casting heat treatments. During the past 4 years the author has performed over 1,000 Birmingham Hip Resurfacingís with a total failure rate of less than 1.0%. 