Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Bone Joint Surg Am ; 99(23): 2020-2025, 2017 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-29206792

RESUMO

BACKGROUND: The fluoroscopically assisted direct anterior approach for total hip arthroplasty has gained interest in recent years. One of the perceived advantages is the use of fluoroscopy to aid in the positioning of implants. The purpose of this study was to measure the radiation entrance surface dose to anatomically important areas of both patients and surgeons during direct anterior approach total hip arthroplasty. METHODS: Radiation dosimetry badges were placed at the sternal notch and pubic symphysis of 50 patients undergoing direct anterior approach total hip arthroplasty. Badges were also placed on the surgeons outside of their lead aprons at the level of the thyroid. Three fellowship-trained arthroplasty surgeons were involved in the study. Radiation exposure of each badge was measured after each case (surgeon and patient). The cumulative dose was also calculated for the surgeons. To limit surgeon bias during the study, 50 consecutive direct anterior approach total hip arthroplasties that occurred prior to this study were analyzed for total fluoroscopic dose and time and served as a control group. RESULTS: Forty-five subjects met study criteria. In the study group, 1 patient had a detectable thyroid exposure equal to 1 mrem. Seven patients had a detectable radiation entrance surface dose at the pubic symphysis (range, 1 to 7 mrem). No radiation entrance surface dose was detectable in the remaining 44 patients at the sternal notch and 38 patients at the pubic symphysis. Surgeons in the study did not experience a detectable radiation entrance surface dose. The mean fluoroscopic time was 13.72 seconds (range, 6.7 to 28.7 seconds). The mean patient radiation exposure was 178 mrem (range, 54 to 526 mrem). CONCLUSIONS: This study demonstrates that during direct anterior approach total hip arthroplasty, the mean patient entrance surface dose at the pubic symphysis and the sternal notch is not detectable in most patients. The mean patient exposure in this study during direct anterior approach total hip arthroplasty was 178 mrem, which is less than a single pelvic radiograph (600 mrem). No surgeon in our study demonstrated a detectable radiation entrance surface dose. Our data suggest that direct anterior approach total hip arthroplasty typically results in a negligible or very low dose of absorbed radiation exposure to the patient and the surgeon. CLINICAL RELEVANCE: We believe this study to have clinical relevance because both patients and surgeons have evidence that utilization of fluoroscopy during direct anterior total hip replacement places both parties at a relatively low radiation exposure risk.


Assuntos
Artroplastia de Quadril/métodos , Exposição Ocupacional , Exposição à Radiação , Cirurgiões , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Proteção Radiológica , Radiometria , Risco
2.
J Knee Surg ; 30(9): 863-871, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28114703

RESUMO

Background Patellofemoral crepitus is a known complication of posterior stabilized (PS) total knee arthroplasty (TKA). This study compared the incidence of patellofemoral crepitus between two femoral components designs. Materials and Methods Between January 2005 and August 2010, 1,120 patients with complete 2-year follow-up had a PS TKA with two different prosthetic designs (group A, 553 patients; group B, 567 patients). Records were reviewed to identify the incidence of total, symptomatic, and operative patellofemoral crepitus. Results No statistical differences were observed in the incidence of total patellofemoral crepitus (group A 14.1%, group B 14.5%; p = 0.932) or symptomatic patellofemoral crepitus (group A 5.6%, group B 4.2%; p = 0.334). The incidence of operative crepitus was greater in group A (3.3%) than in group B (1.3%; p = 0.026). Analysis of mobile versus fixed bearing designs showed a higher incidence of total patellofemoral crepitus in mobile bearing TKA (16.04 vs. 4.93%; p = 0.006) within group B only. Conclusion Femoral component design with a smoother intercondylar box transition zone resulted in a lower incidence of operative patellofemoral crepitus. No statistical differences were noted regarding the incidence of total and symptomatic patellofemoral crepitus. Mobile bearing TKA exhibited greater total crepitus within group B. Level of Evidence Level III.


Assuntos
Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/instrumentação , Artropatias/epidemiologia , Prótese do Joelho , Complicações Pós-Operatórias/epidemiologia , Desenho de Prótese/efeitos adversos , Idoso , Feminino , Fêmur/cirurgia , Humanos , Incidência , Artropatias/cirurgia , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
3.
J Arthroplasty ; 32(4): 1310-1313, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28012722

RESUMO

BACKGROUND: Patellar crepitus is a complication most commonly seen in patients implanted with a posterior-stabilized total knee arthroplasty (TKA). Recently, design changes in the patellofemoral geometry and the intercondylar box ratio have been optimized in newer TKA designs. A comparative study was performed to analyze the incidence of patellar crepitus between a historical vs modern TKA design. METHODS: A retrospective review of all patients at our institution that underwent a primary TKA with either a PFC Sigma or Attune posterior-stabilized TKA (DePuy, Inc, Warsaw, IN), with a minimum of 1-year follow-up duration was performed. A total of 1165 participants implanted with the PFC Sigma and 728 with the Attune design were analyzed. Patellar crepitus incidence, functional scores, and range of motion were recorded at each follow-up appointment. Statistical analyses were performed between the 2 groups to determine if there were differences in clinical outcomes. RESULTS: The incidence of crepitus in participants implanted with the Attune was 0.55% vs 6.26% in the PFC Sigma cohort (P < .001) at 1 year vs. 0.83% vs 9.4%, respectively at 2 years post operatively (P < .001). There were small differences in extension, flexion, and Knee Society Scores between the 2 groups that were not clinically meaningful. CONCLUSION: The Attune posterior-stabilized TKA demonstrated substantially less patellofemoral crepitus incidence than the historical control. We hypothesize that these findings are related to femoral component changes including a thinner and narrower anterior flange and a reduced femoral intercondylar box ratio.


Assuntos
Artroplastia do Joelho/efeitos adversos , Prótese do Joelho/efeitos adversos , Complicações Pós-Operatórias/prevenção & controle , Desenho de Prótese , Idoso , Artroplastia do Joelho/instrumentação , Colorado/epidemiologia , Feminino , Fêmur/cirurgia , Humanos , Incidência , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Patela/cirurgia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Amplitude de Movimento Articular , Estudos Retrospectivos
4.
J Arthroplasty ; 32(1): 220-222, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27369297

RESUMO

BACKGROUND: Use of leukocyte esterase (LE) testing of synovial fluid as an adjunct to the infection workup in total joint arthroplasty patients has been advocated. The purpose of this study was to determine the false positive rate of this test. METHODS: Two hundred patients with the diagnosis of degenerative osteoarthritis undergoing a total knee arthroplasty were identified for this study. The knee joint was aspirated under sterile conditions before performing the total knee arthroplasty. The fluid was analyzed with an LE reagent strip. RESULTS: There were 27 bloody and 17 dry aspirations. One hundred forty-nine patients produced an aspiration that allowed for LE testing. There was 1 positive LE result. The specificity of the LE test was found to be 99.3%. CONCLUSION: These data suggest the LE strip as a part of the workup for infection in a native knee should yield few false positive results.


Assuntos
Artrite Infecciosa/diagnóstico , Hidrolases de Éster Carboxílico/análise , Infecções Relacionadas à Prótese/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho , Reações Falso-Positivas , Feminino , Humanos , Articulação do Joelho , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fitas Reagentes , Sensibilidade e Especificidade , Líquido Sinovial
5.
Hip Int ; 26(4): e35-8, 2016 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-27443223

RESUMO

INTRODUCTION: Physiologic strain patterns of the femur are altered by the bending stiffness of the implant as well as the loading pattern of the implant itself. The Savish Range of Motion (S-ROM) femoral stem has been designed with flutes (to decrease distal material) and with a coronal slot (to decrease stiffness). MATERIALS: The purpose of this case report is to briefly discuss design characteristics of femoral stems and their relationship to thigh pain as well as to describe the only report in the literature of a fracture of the anterior spline of a S-ROM prosthesis at the coronal slot. RESULTS: The femoral stem fractured at the coronal slot due to multiple bending moments in a small diameter stem. CONCLUSIONS: The proximal metaphyseal sleeve remains well fixed and the patient is functioning well without pain nearly a year after the identification of the fracture on routine follow-up.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril/efeitos adversos , Dor Pós-Operatória/etiologia , Idoso , Artroplastia de Quadril/efeitos adversos , Feminino , Humanos , Osteoartrite do Quadril/cirurgia , Dor Pós-Operatória/diagnóstico por imagem , Dor Pós-Operatória/terapia , Desenho de Prótese/efeitos adversos , Falha de Prótese/efeitos adversos , Amplitude de Movimento Articular , Reoperação
6.
Spine (Phila Pa 1976) ; 40(23): E1239-43, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26230542

RESUMO

STUDY DESIGN: Patellar tendon reflexes were elicited among patients who had had a unilateral total knee replacement, those planned for unilateral total knee replacement, and a cohort of controlled patients. Patellar tendon reflex (PTR) response was measured with surface electromyography. OBJECTIVE: The aim of this study was to determine if total knee arthroplasty significantly alters the PTR. SUMMARY OF BACKGROUND DATA: As part of the clinical evaluation of the spine, extremity reflexes are provoked. Reflex variation between right and left extremities can be a pathological finding in disease of the spine. It has been noted that in patients who have undergone total knee arthroplasty (TKA), the PTR is diminished on the operative side compared with the contralateral nonoperative side. PTR is part of the clinical exam when evaluating a patient for lumbar radiculopathy. METHODS: The right and left patellar tendon reflex intensities were measured by quadriceps surface electromyography in 3 groups of patients. Group 1 consisted of 21 patients with unilateral TKA who were at least 6 months postoperative. Group 2 consisted of 18 patients with unilateral severe knee arthritis indicated for TKA. Group 3, serving as the control group, included 20 patients with no evidence of knee arthritis in either knee. The average reflex response for each group was recorded and comparisons were then made between each group. RESULTS: Patients who have undergone unilateral TKA have a PTR on average of 55.1% of their contralateral uninvolved side. This is statistically significant when compared with reflexes in patients who are planned for unilateral total knee arthroplasty, 96.03% (P = 0.001) and when compared with patients without evidence for knee arthritis, 102.2% (P < 0.001). CONCLUSION: The results of this case control study show that TKAs do significantly diminish PTRs when compared with a contralateral uninvolved knee in the same patient. LEVEL OF EVIDENCE: 3.


Assuntos
Artroplastia do Joelho/efeitos adversos , Região Lombossacral/fisiopatologia , Ligamento Patelar/fisiopatologia , Radiculopatia/fisiopatologia , Idoso , Eletromiografia , Feminino , Humanos , Joelho/fisiologia , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/fisiologia
7.
J Knee Surg ; 28(2): 97-104, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25518877

RESUMO

Total knee arthroplasty (TKA) has shown to portend good long-term survivorship and excellent patient satisfaction. There are various etiologies of failure of a TKA. Instability is a major cause of the need for revision. Often, increased constraint is needed to supplement or perform the function of incompetent ligament and soft tissue structures. Posterior cruciate retaining (PCR) TKA has the least constraint. Posterior cruciate substituting (PS) TKA increases sagittal constraint. Varus-valgus constraint (VVC) adds a marked increase in coronal stability. The ultimate in constraint in TKA is a linked hinged implant. In revision TKA, it is the surgeon's responsibility to implant the prosthesis with the necessary constraint to impart adequate stability.


Assuntos
Artroplastia do Joelho/efeitos adversos , Instabilidade Articular/cirurgia , Articulação do Joelho/cirurgia , Humanos , Instabilidade Articular/diagnóstico , Instabilidade Articular/etiologia , Prótese do Joelho , Desenho de Prótese , Falha de Prótese , Falha de Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...