1.
Acta Otolaryngol ; 112(5): 745-51, 1992 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-1456028

RESUMO

A frequency-specific, objective assessment of hearing thresholds is required for use in subjects unable to perform behavioural audiometry. One such method using steady-state evoked potentials (SSEPs) in response to amplitude-modulated tones was evaluated in an experimental animal, the macaque monkey. An amplitude-modulation frequency of 165 Hz was found to produce optimum response detection in the anaesthetised animal. Auditory thresholds determined by a computerised automatic response detection system accurately reflected behavioural thresholds previously described in this species.


Assuntos
Potenciais Evocados Auditivos , Animais , Limiar Auditivo , Macaca fascicularis