Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Chem Chem Phys ; 26(25): 17785-17795, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38874514

RESUMO

The vanadium redox flow battery (VRFB) is considered a promising candidate for large-scale energy storage in the transition from fossil fuels to renewable energy sources. VRFBs store energy by electrochemical reactions of different electroactive species dissolved in electrolyte solutions. The redox couples of VRFBs are VO2+/VO2+ and V2+/V3+, the ratio of which to the total vanadium content determines the state of charge (SOC). V(IV) and V(II) are paramagnetic half-integer spin species detectable and quantifiable with electron paramagnetic resonance spectroscopy (EPR). Common commercial EPR spectrometers, however, employ microwave cavity resonators which necessitate the use of large electromagnets, limiting their application to dedicated laboratories. For an SOC monitoring device for VRFBs, a small, cost-effective submersible EPR spectrometer, preferably with a permanent magnet, is desirable. The EPR-on-a-Chip (EPRoC) spectrometer miniaturises the complete EPR spectrometer onto a single microchip by utilising the coil of a voltage-controlled oscillator as both microwave source and detector. It is capable of sweeping the frequency while the magnetic field is held constant enabling the use of small permanent magnets. This drastically reduces the experimental complexity of EPR. Hence, the EPRoC fulfils the requirements for an SOC sensor. We, therefore, evaluate the potential for utilisation of an EPRoC dipstick spectrometer as an operando and continuously online monitor for the SOC of VRFBs. Herein, we present quantitative proof-of-principle submersible EPRoC experiments on variably charged vanadium electrolyte solutions. EPR data obtained with a commercial EPR spectrometer are in good agreement with the EPRoC data.

2.
Molecules ; 28(18)2023 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-37764252

RESUMO

Graphitic carbon nitride (gCN) materials have been shown to efficiently perform light-induced water splitting, carbon dioxide reduction, and environmental remediation in a cost-effective way. However, gCN suffers from rapid charge-carrier recombination, inefficient light absorption, and poor long-term stability which greatly hinders photocatalytic performance. To determine the underlying catalytic mechanisms and overall contributions that will improve performance, the electronic structure of gCN materials has been investigated using electron paramagnetic resonance (EPR) spectroscopy. Through lineshape analysis and relaxation behavior, evidence of two independent spin species were determined to be present in catalytically active gCN materials. These two contributions to the total lineshape respond independently to light exposure such that the previously established catalytically active spin system remains responsive while the newly observed, superimposed EPR signal is not increased during exposure to light. The time dependence of these two peaks present in gCN EPR spectra recorded sequentially in air over several months demonstrates a steady change in the electronic structure of the gCN framework over time. This light-independent, slowly evolving additional spin center is demonstrated to be the result of oxidative processes occurring as a result of exposure to the environment and is confirmed by forced oxidation experiments. This oxidized gCN exhibits lower H2 production rates and indicates quenching of the overall gCN catalytic activity over longer reaction times. A general model for the newly generated spin centers is given and strategies for the alleviation of oxidative products within the gCN framework are discussed in the context of improving photocatalytic activity over extended durations as required for future functional photocatalytic device development.

3.
Methods Enzymol ; 651: 63-101, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33888211

RESUMO

Many applications of lanthanides exploit their electron spin relaxation properties. Double electron-electron measurements of distances are possible because of the relatively long relaxation times of Gd3+. Relaxation enhancement measurements of distance are possible because of the much shorter relaxation times of other lanthanides. Magnetic resonance imaging contrast agents use the long relaxation time of the S-state Gd3+ ion, and NMR shift reagents use the fast relaxation of selected other lanthanides. Other than Gd3+ and the isoelectronic Eu2+ ion, spin relaxation of the lanthanides is so fast that their EPR spectra can be observed only in the liquid helium temperature range. In this chapter the EPR properties of each of the lanthanides is briefly summarized, with an emphasis on electron spin relaxation.


Assuntos
Elementos da Série dos Lantanídeos , Espectroscopia de Ressonância de Spin Eletrônica , Elétrons , Espectroscopia de Ressonância Magnética
4.
Appl Magn Reson ; 52(8): 1113-1139, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33519097

RESUMO

This review is inspired by the contributions from the University of Denver group to low-field EPR, in honor of Professor Gareth Eaton's 80th birthday. The goal is to capture the spirit of innovation behind the body of work, especially as it pertains to development of new EPR techniques. The spirit of the DU EPR laboratory is one that never sought to limit what an EPR experiment could be, or how it could be applied. The most well-known example of this is the development and recent commercialization of rapid-scan EPR. Both of the Eatons have made it a point to remain knowledgeable on the newest developments in electronics and instrument design. To that end, our review touches on the use of miniaturized electronics and applications of single-board spectrometers based on software-defined radio (SDR) implementations and single-chip voltage-controlled oscillator (VCO) arrays. We also highlight several non-traditional approaches to the EPR experiment such as an EPR spectrometer with a "wand" form factor for analysis of the OxyChip, the EPR-MOUSE which enables non-destructive in situ analysis of many non-conforming samples, and interferometric EPR and frequency swept EPR as alternatives to classical high Q resonant structures.

5.
Magn Reson (Gott) ; 2(2): 673-687, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-37905212

RESUMO

Electron paramagnetic resonance (EPR) spectroscopy is the method of choice to investigate and quantify paramagnetic species in many scientific fields, including materials science and the life sciences. Common EPR spectrometers use electromagnets and microwave (MW) resonators, limiting their application to dedicated lab environments. Here, novel aspects of voltage-controlled oscillator (VCO)-based EPR-on-a-Chip (EPRoC) detectors are discussed, which have recently gained interest in the EPR community. More specifically, it is demonstrated that with a VCO-based EPRoC detector, the amplitude-sensitive mode of detection can be used to perform very fast rapid-scan EPR experiments with a comparatively simple experimental setup to improve sensitivity compared to the continuous-wave regime. In place of a MW resonator, VCO-based EPRoC detectors use an array of injection-locked VCOs, each incorporating a miniaturized planar coil as a combined microwave source and detector. A striking advantage of the VCO-based approach is the possibility of replacing the conventionally used magnetic field sweeps with frequency sweeps with very high agility and near-constant sensitivity. Here, proof-of-concept rapid-scan EPR (RS-EPRoC) experiments are performed by sweeping the frequency of the EPRoC VCO array with up to 400 THz s-1, corresponding to a field sweep rate of 14 kT s-1. The resulting time-domain RS-EPRoC signals of a micrometer-scale BDPA sample can be transformed into the corresponding absorption EPR signals with high precision. Considering currently available technology, the frequency sweep range may be extended to 320 MHz, indicating that RS-EPRoC shows great promise for future sensitivity enhancements in the rapid-scan regime.

6.
Chemphyschem ; 21(22): 2564-2570, 2020 11 17.
Artigo em Inglês | MEDLINE | ID: mdl-32935420

RESUMO

X-band (ca. 9 GHz) fluid solution rapid-scan electron paramagnetic resonance spectra are reported for radicals with multiline spectra and resolution of hyperfine lines as narrow as 30 mG. Highly-resolved spectra of 3-carbamoyl-2,2,5,5-tetramethylpyrrolidin-1-yloxy, diphenylnitroxide, galvinoxyl, and perylene cation radical with excellent signal-to-noise are shown, demonstrating the capabilities of the rapid-scan technique to characterize very small, well-resolved hyperfine couplings. To acquire high resolution spectra the signal bandwidth must be less than the resonator bandwidth. Signal bandwidth is inversely proportional to linewidth and proportional to scan rate. Resonator bandwidth is inversely proportional to resonator Q. Proper selection of scan rate and resonator Q is needed to achieve resolution of closely-spaced narrow EPR lines.


Assuntos
Compostos Benzidrílicos/química , Óxidos N-Cíclicos/química , Óxidos de Nitrogênio/química , Perileno/química , Espectroscopia de Ressonância de Spin Eletrônica , Radicais Livres/química , Estrutura Molecular
7.
J Magn Reson ; 318: 106797, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32769018

RESUMO

Electron spin relaxation times for perdeuterated Finland trityl 99% enriched in 13C at the central carbon (13C1-dFT) were measured in phosphate buffered saline (pH = 7.2) (PBS) solution at X-band. The anisotropic 13C1 hyperfine (Ax = Ay = 18 ± 2, Az = 162 ± 1 MHz) and g values (2.0033, 2.0032, 2.00275) in a 9:1 trehalose:sucrose glass at 293 K and in 1:1 PBS:glycerol at 160 K were determined by simulation of spectra at X-band and Q-band. In PBS at room temperature the tumbling correlation time, τR, is 0.29 ± 0.02 ns. The linewidths are broadened by incomplete motional averaging of the hyperfine anisotropy and T2 is 0.13 ± 0.02 µs, which is shorter than the T2 ~ 3.8 µs for natural abundance dFT at low concentration in PBS. T1 for 13C1-dFT in deoxygenated PBS is 5.9 ± 0.5 µs, which is shorter than for natural abundance dFT in PBS (16 µs) but much longer than in air-saturated solution (0.48 ± 0.04 µs). The tumbling dependence of T1 in PBS, 3:1 PBS:glycerol (τR = 0.80 ± 0.05 ns, T1 = 9.7 ± 0.7 µs) and 1:1 PBS:glycerol (τR = 3.4 ± 0.3 ns, T1 = 12.0 ± 1.0 µs) was modeled with contributions to the relaxation predominantly from modulation of hyperfine anisotropy and a local mode. The 1/T1 rate for the 1% 12C1-dFT in the predominantly 13C labeled sample is about a factor of 6 more strongly concentration dependent than for natural abundance 12C1-trityl, which reflects the importance of Heisenberg exchange with molecules with different resonance frequencies and faster relaxation rates. In glassy matrices at 160 K, T1 and Tm for 13C1-dFT are in good agreement with previously reported values for 12C1-dFT consistent with the expectation that modulation of nuclear hyperfine does not contribute to electron spin relaxation in a rigid lattice.


Assuntos
Carbono/química , Espectroscopia de Ressonância de Spin Eletrônica/métodos , Trítio/química , Algoritmos , Anisotropia , Isótopos de Carbono , Indicadores e Reagentes , Soluções , Marcadores de Spin , Temperatura
8.
Rev Sci Instrum ; 90(2): 024102, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30831717

RESUMO

An X-band (ca. 9-10 GHz) continuous wave saturation recovery spectrometer to measure electron spin-lattice relaxation (T1) was designed around an arbitrary waveform generator (AWG). The AWG is the microwave source and is used for timing of microwave pulses, generation of control signals, and digitizer triggering. Use of the AWG substantially simplifies the hardware in the bridge relative to that in conventional spectrometers and decreases the footprint. The bridge includes selectable paths with different power amplifications to permit experiments requiring hundreds of milliwatts to fractions of nanowatts for the pump and observe periods. The signal is detected with either a single or quadrature-output double balanced mixer. The system can operate with reflection or crossed-loop resonators. The source noise from the AWG was decreased by addition of a Wenzel high-stability clock. The source is sufficiently stable that automatic frequency control is not needed. The spectrometer was tested with samples that contained 1 × 1015 to 8 × 1017 spins and have T1 between a few hundred ns and hundreds of µs. Excellent signal-to-noise ratio was obtained with acquisition times of 2-90 s. Signal-to-noise performance is similar to that of a conventional saturation recovery spectrometer with a solid-state source. The stability and data reproducibility are better than with conventional sources. With replacement of frequency-sensitive components, this spectrometer can be used to perform saturation recovery measurements at any frequency within the range of the AWG.

9.
J Org Chem ; 83(17): 10688-10692, 2018 09 07.
Artigo em Inglês | MEDLINE | ID: mdl-30102044

RESUMO

The radical formed by reduction of 5-bromo-6-oxo-6-phenylhexyl methanesulfonate, an α-bromoketone, with SmI2 was spin trapped with 2-methyl-2-nitrosopropane. Electron paramagnetic resonance spectra of the spin adduct and the adduct formed in the analogous reaction with selectively deuterated substrate identify the radical intermediate in this SmI2 reduction as a carbon-centered radical. This result supports the proposal that the formation of reactive Sm-enolates arises from reduction of the carbon-bromine bond rather than a ketyl radical anion.


Assuntos
Iodetos/química , Compostos Nitrosos/química , Samário/química , Detecção de Spin , Ácidos Sulfônicos/química , Espectroscopia de Ressonância de Spin Eletrônica , Oxirredução
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...