1.
J Investig Med High Impact Case Rep ; 6: 2324709618781174, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29977935

RESUMO

We report an unusual case of endotracheal tube failure. It was due to a manufacturing defect in the internal white plastic piece that is normally depressed by the luer-lock syringe within the blue pilot balloon. Prior to use, the endotracheal tube was tested and functioned normally. A 64-year-old patient in the intensive care unit with a history of hypertension was being mechanically ventilated after uneventful abdominal surgery. After several hours in the intensive care unit, he was noted to be suddenly no longer receiving adequate tidal volumes from the ventilator. It was found that the cuff on the endotracheal tube was not retaining air when it was filled with air from a syringe. This lead to a large "leak" around the endotracheal tube such that the intended tidal volumes set on the ventilator were not delivered to the patient. The patient was uneventfully reintubated and did well. Subsequent investigation revealed the cause to be a manufacturing defect in the internal white plastic piece that is normally depressed by the luer-lock syringe within the blue pilot balloon. Other mechanisms of cuff failure are reviewed in this case report. This case is an unusual reason for cuff failure. Illustrations supplied alert the reader how to identify the appearance of this manufacturing defect in a pilot balloon. This case illustrates the potential device malfunctions that can develop during a procedure, even when the equipment has been tested and previously functioned well. Even small defects developing in well-engineered products can lead to critical patient care emergencies.

2.
J Investig Med High Impact Case Rep ; 6: 2324709618770230, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29707592

RESUMO

Varicella zoster virus causes varicella (chickenpox). It can be reactivated endogenously many years later to cause herpes zoster (shingles). Although varicella is usually a benign disease in healthy children, it resulted in over 11 000 hospitalizations and over 100 deaths every year, in all ages, in the United States. Morbidity was considerably worse in older teenagers and adults. Between 5% and 15% of cases of adult chickenpox will produce some form of pulmonary illness. Progression to pneumonia risk factors include pregnancy, age, smoking, chronic obstructive pulmonary disease, and immunosuppression. Typically, pulmonary symptoms occur 1 to 6 days after varicella zoster infection. They often include cough, fever, and dyspnea. Treatment is a 7-day course of intravenous acyclovir for varicella pneumonia. Early intervention may modify the course of this complication. This review illustrates practical features with a case of a 34-year-old female with severe varicella pneumonia. Despite the lack of significant past medical history and absence of immunosuppression, her pneumonia worsened and by using continuous positive airway pressure mask, intubation was avoided. More important, the radiographic progression of severe varicella pneumonia is shown. This highlights how a common disease of varicella can progress in an adult and manifest with significant organ malfunction.

3.
SAGE Open Med Case Rep ; 6: 2050313X18767228, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29623205

RESUMO

Left internal mammary artery grafting is commonly used in elective coronary artery bypass graft surgery. We report a near-fatal case with graft kinking upon sternal closure due to distended, emphysematous lungs impinging on the mammary graft. After the sternum was closed, the patient suffered a severe hemodynamic deterioration. Surgical examination revealed kinking of his left internal mammary artery upon sternal closure due to distended, emphysematous lungs impinging on the mammary graft. Using an off-bypass technique, the kink in the mammary graft to the left anterior descending artery was removed by moving the origin of the left internal mammary artery to a hooded graft of a saphenous vein graft instead. In this position, the graft no longer was impinged upon by the distended emphysematous lungs. Subsequently, the patient's sternum was closed without hemodynamic impingement. Although chronic obstructive pulmonary disease is well described to increase complications in coronary artery bypass graft surgery, it has not been previously associated with the kinking of a left internal mammary artery. This report highlights another contribution that chronic obstructive pulmonary disease can make to increased morbidity following coronary artery bypass graft surgery and alerts readers to watch for this complication in susceptible patients.