1.
Perfusion ; 26(4): 302-7; discussion 308, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21593087

RESUMO

A 4.3 kg, three-month-old patient, diagnosed with a perimembranous ventricular septal defect, presented for cardiac surgery. Upon initiation of cardiopulmonary bypass (CPB), the patient developed carboxyhemoglobinemia (11.1%). Potential sources for the unexpected acquired carboxyhemoglobinemia were sought quickly. Testing of residual blood from the unit of packed red blood cells (PRBCs) used to prime the CPB circuit revealed a carboxyhemoglobin (COHb) of 15.1 %. A decrease in cerebral oximetry (rSO(2)) on CPB was initially felt to be a result of the elevated COHb levels. When ventilation of the oxygenator with 100% oxygen (O(2)) failed to decrease COHb levels, a partial exchange transfusion was performed with reduction in COHb to 7.1%. The operation was completed successfully and the patient's COHb levels returned to normal within 75 minutes. Post case analysis of events and data collected during the case revealed a broader differential for explaining the compromised patient's O(2) delivery than the transient acquired carboxyhemoglobinemia. A partial obstruction of the superior vena cava could have triggered the drop in rSO(2) on CPB. Follow-up of the donor blood confirmed the donor had previously undiagnosed carboxyhemoglobinemia as a result of chronic carbon monoxide exposure from a faulty vehicle exhaust system.


Assuntos
Doadores de Sangue , Monóxido de Carbono/efeitos adversos , Carboxihemoglobina/análise , Ponte Cardiopulmonar , Comunicação Interventricular/cirurgia , Oximetria , Humanos , Lactente , Masculino , Oxigênio/metabolismo
2.
Perfusion ; 23(1): 39-42, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18788216

RESUMO

In August 2006, Duke University Perfusion Services had the opportunity to be the first institution in the United States to clinically evaluate the Dideco D100 Neonatal Oxygenator. The device was used on six pediatric patients to facilitate correction or palliation of their cardiac defects, which included two arterial switch operations, two truncus arteriosus repairs, one stage 1 Norwood and one repair of total anomalous pulmonary venous return. The average patient weight was 3.1 kg. The average cardiopulmonary bypass (CPB) time was 135 minutes and the average cross-clamp time was 61 minutes. Arterial and venous blood gasses were drawn and used to calculate oxygen transfer. The average oxygen transfer was 14.8 +/- 10.3 ml/O2/min. The Dideco D100 Oxygenator is the first oxygenation device designed specifically for neonates. The Dideco D100 is a microporous hollow-fiber device. It has a static priming volume of 31 ml and a maximum rated flow of 700 ml/min. The integral hard-shell venous reservoir has a minimum operating level of 10 ml and a reservoir capacity of 500 ml. For this evaluation, the Dideco Kids D100 Neonatal Oxygenator performed adequately on patients weighing up to 5 kg. This device provides an excellent first step towards offering very small children appropriate circuitry without having to sacrifice safety or performance.


Assuntos
Ponte Cardiopulmonar/instrumentação , Oxigenadores , Ponte Cardiopulmonar/métodos , Feminino , Cardiopatias/cirurgia , Humanos , Lactente , Recém-Nascido , Masculino