Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
2.
Lab Invest ; 103(10): 100224, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37517701

RESUMO

In an anatomical pathology laboratory, liquid chromatography-tandem mass spectrometry (LC-MS/MS) is used to characterize amyloid deposits identified in formalin-fixed paraffin-embedded tissue (FFPET). However, the development of additional tests is partially limited by the lack of information the passage of time has on the proteins in FFPET. To investigate the reliability of LC-MS/MS in the analysis of old FFPET specimens, 1 bone marrow aspirate clot was analyzed by LC-MS/MS yearly from 2014 to 2018, in 3 consecutive months. Peptide-spectrum match, number of peptides identified, and percentage of the proteins covered were the parameters collected for the hemoglobin subunits alpha (HbA), beta (HbB), delta (HbD), and gamma (HbG). These proteins are constant components of the peripheral blood and are present in high and low abundance, allowing the monitorization of the performance of the test across varying protein concentrations. The hemoglobin subunits were stable over the years studied; 71% to 74% of HbA, 77% to 80% of HbB, 69% to 77% of HbD, and 57% to 63% of HbG were covered, with no statistical difference between 2014 and 2018. The number of peptides identified was also constant, 11 to 13 for HbA, 13 to 15 for HbB, 11 to 14 for HbD, and 7 to 9 for HbG. Peptide spectrum match was only slightly more variable: 209 to 327 for HbA, 569 to 1052 for HbB, 286 to 533 HbD, and 142 to 292 for HbG. In conclusion, high abundance hemoglobins, HbA and HbB, and relatively low abundance ones, HbD and HbG, are preserved in FFPET and confidently identified by LC-MS/MS for at least 5 years.


Assuntos
Formaldeído , Espectrometria de Massas em Tandem , Cromatografia Líquida , Formaldeído/química , Inclusão em Parafina/métodos , Espectrometria de Massas em Tandem/métodos , Reprodutibilidade dos Testes , Proteínas , Peptídeos , Subunidades de Hemoglobina/análise , Fixação de Tecidos/métodos
4.
Clin Biochem ; 115: 126-128, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35779575

RESUMO

The preanalytical phase of testing accounts for the majority of the errors. Software-based quality rules, such as autoverification, can assist in preanalytical error detection; therefore, preventing erroneous results from being reported. Two autoverification rules, turbidity/lipemia, and pseudohypoglycemia/pseudohyperkalemia alarms, are highlighted. Increased sample turbidity may arise from several causes outside of lipemia. Typically, this can be resolved by clarifying the sample with standard centrifugation. Truly lipemic specimens typically require higher centrifugation speeds and greater centrifugation time. At our facility, 96% of direct bilirubin (DBIL), 95% of aspartate transaminase (AST), and 98% of alanine transaminase (ALT) turbidity/lipemia alarms were found to be from sample turbidity versus lipemia. Secondly, a pseudohypoglycemia/pseudohyperkalemia rule was employed for specimens with delayed separation from cellular material. Of the total potassium results >6.0 mmol/L or glucose results <40 mg/dL (2.2 mmol/L), 30% and 50% respectively were noted to have delayed sample separation.


Assuntos
Algoritmos , Software , Humanos , Alanina Transaminase , Aspartato Aminotransferases , Bilirrubina
5.
Sex Transm Dis ; 49(8): 546-550, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35587394

RESUMO

BACKGROUND: The Centers for Disease Control and Prevention (CDC) and US Preventive Services Task Force (USPSTF) guidelines recommend screening for human immunodeficiency virus (HIV) in patients aged 15 to 65 years, as well as those at increased risk. Patients screened in the emergency department (ED) for gonorrhea (GC) and/or chlamydia represent an increased-risk population. Our aim was to assess compliance with CDC and USPSTF guidelines for HIV testing in a national sample of EDs. METHODS: We examined data from the 2010 to 2018 Nationwide Emergency Department Sample, which can be used to create national estimates of ED care to query tests for GC, chlamydia, HIV, and syphilis testing. Weighted proportions and 95% confidence intervals (CIs) were reported, and Rao-Scott χ 2 tests were used. RESULTS: We identified 13,443,831 (weighted n = 3,094,214) high-risk encounters in which GC/chlamydia testing was performed. HIV screening was performed in 3.9% (95% CI, 3.4-4.3) of such visits, and syphilis testing was performed in 2.9% (95% CI, 2.7-3.2). Only 1.5% of patients with increased risk encounters received both HIV and syphilis cotesting. CONCLUSIONS: Despite CDC and USPSTF recommendations for HIV and syphilis screening in patients undergoing STI evaluation, only a small proportion of patients are being tested. Further studies exploring the barriers to HIV screening in patients undergoing STI assessment in the ED may help inform future projects aimed at increasing guidance compliance.


Assuntos
Infecções por Chlamydia , Chlamydia , Gonorreia , Infecções por HIV , Infecções Sexualmente Transmissíveis , Sífilis , Infecções por Chlamydia/epidemiologia , Serviço Hospitalar de Emergência , Gonorreia/diagnóstico , Gonorreia/epidemiologia , HIV , Infecções por HIV/diagnóstico , Infecções por HIV/epidemiologia , Humanos , Programas de Rastreamento , Infecções Sexualmente Transmissíveis/diagnóstico , Infecções Sexualmente Transmissíveis/epidemiologia , Sífilis/diagnóstico , Sífilis/epidemiologia
6.
Clin Biochem ; 101: 16-18, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34848174

RESUMO

BACKGROUND: Immunoassays used to measure total and free thyroxine (T4 and FT4) and total and free triiodothyronine (T3 and FT3) can provide inaccurate results due to interference from endogenous autoantibodies. CASE REPORT: A 74-year-old female treated for hypothyroidism with levothyroxine replacement had elevated thyroid stimulating hormone (TSH), FT4, and FT3. Due to concern for hyperthyroidism, levothyroxine was discontinued and further workup was initiated. A pituitary MRI revealed a microadenoma but the alpha-subunit was normal. She was given octreotide for suspected TSH secreting pituitary adenoma without improvement in her TSH, FT4, or FT3 levels. She was referred to our clinic, where inaccurate lab values for FT4 and FT3 were suspected. RESULTS: Testing via equilibrium dialysis liquid chromatography tandem mass spectrometry (LC-MS/MS) method revealed lower levels of FT4 and FT3. Subsequent testing included heterophile blocking tube treatment, polyethylene glycol (PEG) precipitation, and anti-T3/T4 autoantibody levels. The tests revealed thyroid hormone autoantibodies (THAAs) as the cause of immunoassay interference. CONCLUSIONS: When thyroid hormones are elevated and TSH is not suppressed, confirmatory testing with another method such as equilibrium dialysis LC-MS/MS, which is not susceptible to interference from autoantibodies, should be considered.


Assuntos
Autoanticorpos/imunologia , Tiroxina/sangue , Tri-Iodotironina/sangue , Idoso , Erros de Diagnóstico , Feminino , Humanos , Imunoensaio , Neoplasias Hipofisárias/diagnóstico , Testes de Função Tireóidea , Síndrome da Resistência aos Hormônios Tireóideos/diagnóstico , Tireotropina/sangue , Tiroxina/imunologia , Tri-Iodotironina/imunologia
9.
J Appl Lab Med ; 5(2): 357-362, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-32445379

RESUMO

BACKGROUND: Carbamazepine is an effective drug for treating seizures and trigeminal neuralgia. Therapeutic drug monitoring of free carbamazepine in serum can be useful in situations that drug--protein binding is altered to guide regimen adjustment and to aid in the diagnosis of clinical toxicity. METHODS: Separation of the nonprotein bound carbamazepine was achieved via ultrafiltration through a molecular weight cut-off filter. A method for free carbamazepine measurement was developed on the automated cobas chemistry analyzers (Roche Diagnostics) by modifying the Carbamazepine Gen 4 assay (Roche Diagnostics). Assay performance characteristics were established including precision, accuracy, reportable range, analytical specificity, and stability. RESULTS: The intra- and inter-assay imprecision was 0%-1.4% and 2.4%-5.1%, respectively. The lower limit of quantitation was 0.3 µg/mL, and the assay was linear up to 10.0 µg/mL. A spike recovery study, using reference standard material, showed recovery was 93.5%--101.3% across the analytical measurement range. Method comparison with a reference laboratory method demonstrated equivalent performance with a slope of 1.01, intercept of 0.09, and correlation coefficient of 0.9948. CONCLUSION: This assay provides a simple and accurate method for monitoring free carbamazepine with a fast turnaround time.


Assuntos
Anticonvulsivantes/sangue , Carbamazepina/sangue , Monitoramento de Medicamentos/instrumentação , Monitoramento de Medicamentos/métodos , Anticonvulsivantes/farmacocinética , Automação , Carbamazepina/farmacocinética , Monitoramento de Medicamentos/normas , Humanos , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
Clin Chim Acta ; 505: 98-99, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32035850

RESUMO

BACKGROUND: The fifth generation (high-sensitivity) troponin T assay offers increased precision and analytical sensitivity to the predecessor method. The assay has proven utility in risk stratification and patient management. Upon clinical suspicion and discordant 4th generation troponin T and troponin I results, we investigated a sample for suspected interfering substances to the 5th generation troponin T assay. METHODS: The analysis included a serial dilution, treatment with polyethylene glycol, commercial antibody blocking reagents, and size exclusion chromatography. RESULTS: The sample diluted linearly (R2 = 0.9957); however, experienced a dramatic reduction in concentration after both the polyethylene glycol and blocking agent treatment. Finally, size exclusion chromatography demonstrated assay reactivity around 970 kDa range. CONCLUSIONS: These experiments elucidate a heterophilic antibody interference to the assay, and demonstrate potential measures to discern the interference.


Assuntos
Anticorpos/análise , Troponina T/análise , Idoso , Cromatografia em Gel , Eletrocardiografia , Reações Falso-Positivas , Feminino , Humanos , Imunoensaio , Técnicas de Diluição do Indicador , Indicadores e Reagentes , Imageamento por Ressonância Magnética , Polietilenoglicóis/análise , Sensibilidade e Especificidade , Cardiomiopatia de Takotsubo/diagnóstico , Cardiomiopatia de Takotsubo/diagnóstico por imagem
11.
Clin Chem ; 65(9): 1183, 2019 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32100853
12.
Clin Chim Acta ; 486: 205-208, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30098951

RESUMO

BACKGROUND: A transition ion ratio (TIR) is the ratio of one fragment over another from the same precursor and is frequently monitored in liquid chromatography-tandem mass spectrometry (LC-MS/MS) assays for analyte identification. The Clinical and Laboratory Standards Institute (CLSI) C50-A guidelines give a static percent allowable TIR deviation based on the TIR level. Anecdotally, we observed failures of these rules for some of our LC-MS/MS assays. We determined what parameters may affect TIRs in a clinical setting and whether TIR variations may be analyte, matrix, instrument service, and/or concentration dependent. METHODS: Data was collected from the validation and selected periods after implementation for urine benzodiazepines (7 analytes) and plasma azole antifungals (6 analytes). TIRs for the calibrators and quality control materials on a Thermo TSQ™ Quantum Ultra from July 2016 to February 2017 for benzodiazepines in urine and Thermo TSQ™ Vantage from May 2016 to Oct 2016 for azoles in serum were monitored. RESULTS: The statistically significant day-to-day TIR shift ranged from 5.7 to 27.0% of the days studies for benzodiazepines and from 5.6 to 27.8% of the days studied for azoles excluding shifts caused by instrument services. Instrument service had significant impact on all benzodiazepines except oxazepam with p-values ranging from 1.79 × 10-6 to 1.53 × 10-39 and 4 of the 6 azoles (fluconazole, isavuconazole, voriconazole, and itraconazole) with (p from 7.89 × 10-3 to 1.98 × 10-12). Lorazepam, α-hydroxyalprazolam, and hydroxyitraconazole showed significant concentration dependent TIR variations. CONCLUSIONS: TIR variations may be affected by instrument services, and can be concentration and analyte dependent. Instead of using a static percent deviation rule, establishment of TIR variation criteria for each analyte during test development and validation may provide a more useful tool for analyte identification.


Assuntos
Antifúngicos/sangue , Azóis/sangue , Benzodiazepinas/urina , Técnicas de Química Analítica , Técnicas de Laboratório Clínico , Técnicas de Química Analítica/normas , Cromatografia Líquida/normas , Técnicas de Laboratório Clínico/normas , Humanos , Íons/sangue , Íons/urina , Espectrometria de Massas em Tandem/normas
13.
Clin Chim Acta ; 474: 8-13, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28864232

RESUMO

BACKGROUND: Azole antifungal medications are often administered to prevent or treat invasive fungal infections. These infections are deadly in the immunocompromised population. Therapeutic drug monitoring of the azole antifungal medications may potentially decrease morbidity and mortality in patients undergoing azole treatment. METHODS: To assist with azole therapeutic drug monitoring, a liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed and validated for 6 azole analytes: fluconazole, voriconazole, posaconazole, isavuconazole, itraconazole, and its active metabolite hydroxyitraconazole. RESULTS: The validated method solely required a protein precipitation step before subsequent dilution and injection onto the LC-MS/MS system. Furthermore, the analysis time was <2min per sample. CONCLUSIONS: This method enables measurement of all 6 of these analytes into a single LC-MS/MS assay.


Assuntos
Antifúngicos/sangue , Antifúngicos/metabolismo , Azóis/sangue , Azóis/metabolismo , Análise Química do Sangue/métodos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Humanos , Fatores de Tempo
14.
Anal Chem ; 89(12): 6295-6299, 2017 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-28570047

RESUMO

Unified analysis of complex reactions of an activity-based probe with proteins in a proteome remains an unsolved challenge. We propose a power expression, rate = kobs[Probe]α, for scaling the progress of proteome-wide reactions and use the scaling factor (0 ≤ α ≤ 1) as an apparent, partial order with respect to the probe to measure the "enzyme-likeness" for a protein in reaction acceleration. Thus, α reports the intrinsic reactivity of the protein with the probe. When α = 0, the involved protein expedites the reaction to the maximal degree; when α = 1, the protein reacts with the probe via an unaccelerated, bimolecular reaction. The selectivity (ß) of the probe reacting with two proteins is calculated as a ratio of conversion factors (kobs values) for corresponding power equations. A combination of α and ß provides a tiered system for quantitatively assessing the probe efficacy; an ideal probe exhibits high reactivity with its protein targets (low in α) and is highly selective (high in ß) in forming the probe-protein adducts. The scaling analysis was demonstrated using proteome-wide reactions of HT-29 cell lysates with a model probe of threonine ß-lactone.


Assuntos
Lactonas/química , Sondas Moleculares/química , Proteoma/análise , Treonina/química , Células HT29 , Humanos , Estrutura Molecular
15.
Autism Res ; 10(9): 1460-1469, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28509388

RESUMO

Proteomics, the large-scale study of protein expression in cells and tissues, is a powerful tool to study the biology of clinical conditions and has provided significant insights in many experimental systems. Herein, we review the basics of proteomic methodology and discuss challenges in using proteomic approaches to study autism. Unlike other experimental approaches, such as genomic approaches, there have been few large-scale studies of proteins in tissues from persons with autism. Most of the proteomic studies on autism used blood or other peripheral tissues; few studies used brain tissue. Some studies found dysregulation of aspects of the immune system or of aspects of lipid metabolism, but no consistent findings were noted. Based on the challenges in using proteomics to study autism, we discuss considerations for future studies. Apart from the complex technical considerations implicit in any proteomic analysis, key nontechnical matters include attention to subject and specimen inclusion/exclusion criteria, having adequate sample size to ensure appropriate powering of the study, attention to the state of specimens prior to proteomic analysis, and the use of a replicate set of specimens, when possible. We conclude by discussing some potentially productive uses of proteomics, potentially coupled with other approaches, for future autism research including: (1) proteomic analysis of banked human brain specimens; (2) proteomic analysis of tissues from animal models of autism; and (3) proteomic analysis of induced pluripotent stem cells that are differentiated into various types of brain cells and neural organoids. Autism Res 2017, 10: 1460-1469. © 2017 International Society for Autism Research, Wiley Periodicals, Inc.


Assuntos
Transtorno do Espectro Autista/metabolismo , Proteômica/métodos , Animais , Transtorno do Espectro Autista/genética , Encéfalo/metabolismo , Humanos , Proteínas/metabolismo
19.
Clin Chim Acta ; 454: 1-5, 2016 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-26721314

RESUMO

Immunosuppressant medications allow the transplantation of tens of thousands of allografts per year and consequently have great potential to decrease patient morbidity and mortality. However, some medications have great risk associated with over- and under-dosing leading to adverse effects or allograft rejection, respectively. This necessitates immunosuppressant therapeutic drug monitoring accomplished by immunoassay or liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). The former's accuracy can be hindered by metabolites of immunosuppressant medications, antibodies against these medications and heterophilic antibodies. Although LC-MS/MS has superior specificity which allows it to be less susceptible to interference, this methodology lacks standardization and the necessary throughput. Recent developments in LC-MS/MS quantitation, however, include patient-friendly sample submission as dried blood spots, higher sample throughput and commercialization. Here we critically review recent LC-MS/MS publications (January 2010 to July 2015) on the quantitation of cyclosporine A, tacrolimus, sirolimus and everolimus.


Assuntos
Ciclosporina/análise , Monitoramento de Medicamentos , Everolimo/análise , Imunossupressores/análise , Sirolimo/análise , Tacrolimo/análise , Cromatografia Líquida , Humanos , Imunoensaio , Conformação Molecular , Espectrometria de Massas em Tandem
20.
Anal Chem ; 87(17): 8603-7, 2015 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-26236917

RESUMO

A targeted mass spectrometry-based method is presented that adopts the fast photochemical oxidation of proteins (FPOP) for footprinting of cystic fibrosis transmembrane conductance regulator (CFTR) membrane transporter at its original plasma membrane location. Two analytical imperatives were sought: (1) overall simplification in data acquisition and analysis and (2) lower quantitation limits, which enabled direct analysis of intrinsically low-abundance transmembrane proteins. These goals were achieved by using a reversed-footprinting technique that monitored the unoxidized peptides remaining after the FPOP treatment. In searching for structurally informative peptides, a workflow was designed for accurate and precise quantitation of CFTR peptides produced from proteolytically digesting the plasma membrane subproteome of cells. This sample preparation strategy mitigated the need for challenging purification of large quantities of structurally intact CFTR. On the basis of the interrogated peptides, it was proposed a concept of the structural marker peptide that could report CFTR structure and function in cells. The reversed-footprinting mass spectrometry extends the FPOP technology to study conformation and interaction changes of low-abundance proteins directly in their endogenous cellular locations.


Assuntos
Biomarcadores/química , Membrana Celular/química , Regulador de Condutância Transmembrana em Fibrose Cística/química , Espectrometria de Massas , Peptídeos/química , Pegadas de Proteínas , Sequência de Aminoácidos , Biomarcadores/metabolismo , Membrana Celular/metabolismo , Regulador de Condutância Transmembrana em Fibrose Cística/metabolismo , Humanos , Modelos Biológicos , Oxirredução
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...