Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMJ Open Qual ; 10(3)2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34413067

RESUMO

BACKGROUND: In a tertiary respiratory centre, large cohorts of patients are managed in an outpatient setting and require blood tests to monitor disease activity and organ toxicity. This requires either visits to tertiary centres for phlebotomy and physician review or utilisation of primary care services. OBJECTIVES: This study aims to validate remote capillary blood testing in an outpatient setting and analyse impact on clinical pathways. METHODS: A single-centre prospective cross-sectional validation and parallel observational study was performed. Remote finger prick capillary blood testing was validated compared with local standard venesection using comparative statistical analysis: paired t-test, correlation and Bland-Altman. Capillary was considered interchangeable with venous samples if all three criteria were met: non-significant paired t-test (ie, p>0.05), Pearson's correlation coefficient (r)>0.8% and 95% of tests within 10% difference through Bland-Altman (limits of agreement). In parallel, current clinical pathways including phlebotomy practice were analysed over 4 weeks to review test predictability. A subsequent pilot cohort study analysed potential impact of remote capillary blood sampling on shared decision making. A final implementation phase ensued to embed the service into clinical pathways within the institution. RESULTS: 117 paired capillary and venous blood samples were prospectively analysed. Interchangeability with venous blood was seen with glycated haemoglobin (%), total protein and C reactive protein. Further tests, although not interchangeable, are likely useful to enable longitudinal remote monitoring (eg, liver function and total IgE). 65% of outpatient clinic blood tests were predictable with 16% of patients requiring further follow-up. Patient and clinician-reported improvement in shared decision making given contemporaneous blood test results was observed. CONCLUSIONS: Remote capillary blood sampling can be used accurately for specific tests to monitor chronic disease, and when incorporated into an outpatient clinical pathway can improve shared decision making and patient experience. Further research is required to determine health economic impact and applicability within telemedicine-based outpatient care.


Assuntos
Instituições de Assistência Ambulatorial , Tomada de Decisão Compartilhada , Estudos Transversais , Testes Hematológicos , Humanos , Projetos Piloto , Estudos Prospectivos
2.
Thorax ; 75(8): 632-639, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32409613

RESUMO

INTRODUCTION: Individuals with chronic lung disease (eg, cystic fibrosis (CF)) often receive antimicrobial therapy including aminoglycosides resulting in ototoxicity. Extended high-frequency audiometry has increased sensitivity for ototoxicity detection, but diagnostic audiometry in a sound-booth is costly, time-consuming and requires a trained audiologist. This cross-sectional study analysed tablet-based audiometry (Shoebox MD) performed by non-audiologists in an outpatient setting, alongside home web-based audiometry (3D Tune-In) to screen for hearing loss in adults with CF. METHODS: Hearing was analysed in 126 CF adults using validated questionnaires, a web self-hearing test (0.5 to 4 kHz), tablet (0.25 to 12 kHz) and sound-booth audiometry (0.25 to 12 kHz). A threshold of ≥25 dB hearing loss at ≥1 audiometric frequency was considered abnormal. Demographics and mitochondrial DNA sequencing were used to analyse risk factors, and accuracy and usability of hearing tests determined. RESULTS: Prevalence of hearing loss within any frequency band tested was 48%. Multivariate analysis showed age (OR 1.127; (95% CI: 1.07 to 1.18; p value<0.0001) per year older) and total intravenous antibiotic days over 10 years (OR 1.006; (95% CI: 1.002 to 1.010; p value=0.004) per further intravenous day) were significantly associated with increased risk of hearing loss. Tablet audiometry had good usability, was 93% sensitive, 88% specific with 94% negative predictive value to screen for hearing loss compared with web self-test audiometry and questionnaires which had poor sensitivity (17% and 13%, respectively). Intraclass correlation (ICC) of tablet versus sound-booth audiometry showed high correlation (ICC >0.9) at all frequencies ≥4 kHz. CONCLUSIONS: Adults with CF have a high prevalence of drug-related hearing loss and tablet-based audiometry can be a practical, accurate screening tool within integrated ototoxicity monitoring programmes for early detection.


Assuntos
Fibrose Cística/complicações , Perda Auditiva/diagnóstico , Perda Auditiva/epidemiologia , Adulto , Audiometria , Computadores de Mão , Estudos Transversais , Fibrose Cística/terapia , Feminino , Humanos , Internet , Masculino , Pessoa de Meia-Idade , Prevalência , Fatores de Risco , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...