Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eye (Lond) ; 32(1): 39-43, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29192679

RESUMO

PurposeThe post-LASIK exacerbation of corneal dystrophy, otherwise asymptomatic, is almost exclusively associated with the TGFBI gene mutations at codon 124 in exon 4 and codon 555 in exon 12. It is our intention to demonstrate that the pre-operative genetic screening for TGFBI mutations should be mandatory for refractive surgery candidates.Patients and MethodsIn this study, we reviewed the proband's post-LASIK slit-lamp and in vivo confocal microscopy images and genetic testing results, and performed genetic testing on eleven additional members of the family to investigate the penetrance of corneal dystrophy in asymptomatic members who carry the mutation.ResultsThe proband demonstrated a post-LASIK exacerbation of Granular Corneal Dystrophy type 2 (GCD2), identified as a TGFBI R124H mutation. Three of the 11 family members tested positive for the same R124H mutation as the proband.ConclusionThe lesson learned from this case is that the genetic screening of TGFBI mutations must be incorporated into the pre-operative screening procedures to prevent exacerbation and recurrence, which eventually could lead to the need for a corneal transplant.


Assuntos
Córnea/patologia , Distrofias Hereditárias da Córnea/genética , Proteínas da Matriz Extracelular/genética , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Mutação , Fator de Crescimento Transformador beta/genética , Adolescente , Adulto , Criança , Córnea/metabolismo , Distrofias Hereditárias da Córnea/diagnóstico , Distrofias Hereditárias da Córnea/metabolismo , Análise Mutacional de DNA , Proteínas da Matriz Extracelular/metabolismo , Feminino , Testes Genéticos , Humanos , Masculino , Linhagem , Fenótipo , Reação em Cadeia da Polimerase , Fator de Crescimento Transformador beta/metabolismo
2.
Eye (Lond) ; 30(7): 972-8, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27080489

RESUMO

PurposeTo investigate early changes in choroidal thickness (CT) and the relationship with accommodation after myopic excimer laser surgery.MethodsWe enrolled the right eye of 70 patients with myopia and without other ophthalmic or systemic diseases who were suitable for myopic excimer laser surgery. The CT was measured at the fovea and at distances of 0.5 and 2.5 mm for the following: nasal; temporal; superior; and inferior to the fovea preoperatively and at 1 month postoperatively. Other data collected included demographic information (age, sex, and refractive error), the amplitude of accommodation (AA), intraocular pressure, axial length, corneal thickness, and surgical parameters. The data were analyzed with a paired Student's t-test, stepwise linear regression, and correlation analysis.ResultsThe CT was significantly thicker postoperatively compared with the preoperative CT. The AA significantly decreased postoperatively. The change in the AA was the most significant factor associated with the change in the CT at the fovea. Except for 2.5 mm inferior to the fovea, the increase in the CT at other locations was positively correlated with the decrease in the AA.ConclusionsThe CT increased following myopic excimer laser surgery and the change was most obvious when accompanied by a decrease in the AA early after the surgery.


Assuntos
Acomodação Ocular/fisiologia , Corioide/patologia , Ceratectomia Subepitelial Assistida por Laser/métodos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Adulto , Corioide/diagnóstico por imagem , Feminino , Humanos , Masculino , Miopia/fisiopatologia , Tomografia de Coerência Óptica , Adulto Jovem
3.
Biomaterials ; 22(10): 1137-46, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11352093

RESUMO

The first goal of this study was to examine the influence that poly(ethylene oxide)-block-poly(D,L-lactide) (PELA) copolymer can have on the wettability, the in vitro controlled delivery capability, and the degradation of poly(D,L-lactide) (PDLLA) foams. These foams were prepared by freeze-drying and contain micropores (10 microm) in addition of macropores (100 microm) organized longitudinally. Weight loss, water absorption, changes in molecular weight, polymolecularity (Mw/Mn) and glass transition temperature (Tg) of PDLLA foams mixed with various amounts of PELA were followed with time. It was found that 10wt% of PELA increased the wettability and the degradation rate of the polymer foams. The release of sulforhodamine (SR) was compared for PDLLA and PDLLA-PELA foams in relation with the foam porosity. An initial burst release was observed only in the case of the 90:10 PDLLA/PELA foam. The ability of the foam of this composition to be integrated and to promote tissue repair and axonal regeneration in the transected rat spinal cord was investigated. After implantation of ca. 20 polymer rods assembled with fibrin-glue, the polymer construct was able to bridge the cord stumps by forming a permissive support for cellular migration, angiogenesis and axonal regrowth.


Assuntos
Materiais Biocompatíveis , Fator 1 de Crescimento de Fibroblastos/administração & dosagem , Regeneração Nervosa/fisiologia , Poliésteres , Polietilenoglicóis , Traumatismos da Medula Espinal/fisiopatologia , Traumatismos da Medula Espinal/terapia , Animais , Técnicas In Vitro , Teste de Materiais , Microscopia Eletrônica de Varredura , Ratos , Ratos Wistar , Rodaminas/administração & dosagem , Rodaminas/farmacocinética , Traumatismos da Medula Espinal/patologia
4.
J Biomed Mater Res ; 54(3): 335-43, 2001 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-11189038

RESUMO

Although bioresorbable aliphatic polyesters derived from lactic acid are now used clinically as sutures, bone-fracture fixation devices and sustained-release drug-delivery systems, very little is known about their behavior in the infected environment. The aim of the present study was to compare the resistance to infection of two polylactide implants with different degradation characteristics, and to evaluate the influence of a bacterial challenge on their mechanical and physicochemical properties. Various quantities of a beta-haemolyzing strain of Staphylococus aureus (V 8189-94) were inoculated into the medullary cavity of rabbit tibiae, and an extruded polylactide rod composed of either P(L)LA (Poly(L-Lactide)) or P(L/DL)LA (Poly(L/DL-Lactide)) was then inserted. Animals were sacrificed four weeks after surgery. The tibiae and implants were removed under sterile conditions and evaluated microbiologically by culturing. The severity of infection was graded according to positive colony-forming units in the bone. The mechanical properties of the retrieved implants were assessed by 4-point bending and shear tests, performed in compliance with the ASTM D790 standard and their physicochemical characteristics also were characterized. P(L)LA and P(L/DL)LA implants were equally resistant to local infection, their mechanical and physicochemical properties being unaffected by bacterial challenge. Hence, once an infection has become established, the release of bactericidal/bacteriostatic by-products during implant degradation does not appear to affect its natural course. The release of bactericidal/bacteriostatic degradation products at the implantation site is unlikely to affect the natural course of an established infection.


Assuntos
Materiais Biocompatíveis , Poliésteres , Infecções Relacionadas à Prótese/microbiologia , Infecções Estafilocócicas/microbiologia , Animais , Materiais Biocompatíveis/química , Fenômenos Químicos , Físico-Química , Cromatografia em Gel , Cristalização , Análise Diferencial Térmica , Teste de Materiais , Peso Molecular , Infecções Relacionadas à Prótese/patologia , Coelhos , Infecções Estafilocócicas/etiologia , Infecções Estafilocócicas/patologia , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...