Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Oper Dent ; 49(1): 76-83, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38019216

RESUMO

OBJECTIVE: To evaluate the influence of post-cure heat treatments (PCHT) on Knoop microhardness (KHN) and color change of bis-acryl composite resin (Protemp 4 - 3M ESPE, USA and PrimmaArt - FGM, Brazil) and chemically activated acrylic resins (Dencôr - Clássico, Brazil, and Duralay - Cotia, Brazil). METHODS AND MATERIALS: Specimens (12×1 mm) were prepared for each material (n=10/group). Thirty minutes after curing, the specimens were subjected to PCHT for 10 minutes at 70°, 100°, or 130°C. The control group was kept at room temperature (24°C) for the same amount of time. KHN was analyzed 24 hours after PCHT (n=10). Following Commission Internationale de l'Éclairage (CIE) Delta E 2000 (CIEDE2000 [ΔE00]), color measurements were obtained at three time points: 1. after polymerization; 2. after PCHT; and 3. after 30 days of storage in water, coffee, or red wine. Data for each material were analyzed by one-way analysis of variance (ANOVA) (p<0.05). RESULTS: The PCHT at 130°C produced the highest KHN values. Except for the 70°C groups from Dencôr and Protemp, all PCHTs increased the initial color values (p>0.05). In general, chemically activated acrylic resins showed an increase in color stability when subjected to PCHT (p>0.05). For bis-acryl composite resin, PCHT did not influence color stability (p<0.05). CONCLUSION: Overall, the results showed that PCHT increased the tested materials' color changes and Knoop microhardness. However, except for PCHT at 130°C in Duralay, the color changes remained within acceptable values. The PCHT treatment resulted in better color stability for most of the composite resins studied.


Assuntos
Resinas Compostas , Temperatura Alta , Resinas Compostas/uso terapêutico , Resinas Compostas/química , Resinas Acrílicas/química , Polimetil Metacrilato/química
2.
Oper Dent ; 48(2): 186-195, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36656314

RESUMO

OBJECTIVE: To evaluate the influence of different surface treatments on topography, surface roughness, surface energy, and microtensile bond strength stability of resin cement to lithium disilicate glass ceramic. METHODS AND MATERIALS: Seventy disc-shaped specimens of IPS e.max Press were divided into seven groups according to the surface treatment: NT - non-treated (control); FSil - hydrofluoric acid (HF) + silane; FPSil - HF + phosphoric acid (HP) + silane; FUSil - HF + ultrasonic bath (U) + silane; FPUSil - HF + HP + U + silane; MEP - Monobond Etch and Prime (MEP); and MEPH - MEP + heating. Topography and surface roughness were evaluated using a 3D laser confocal microscope (3DLCM) and scanning electron microscopy (SEM) and surface energy with a goniometer. The microtensile bond strength (µTBS) was evaluated after storage in distilled water at 37°C for 24 hours and after thermocycling (5,000 cycles, 5°-55° C, 30-second dwell time). Data were analyzed using one-way ANOVA (surface roughness and surface energy), two-way ANOVA (µTBS), Tukey's HSD post-hoc test, and Student t-test (α=0.05). RESULTS: FUSil, FPSil, and FSil presented similar and highest surface roughness, whereas NT, FPUSil, MEP, and MEPH showed similar, and lowest, roughness values (p<0.05). FPUSil, FPSil, FUSil, and FSil presented a similar and highest surface energy. NT, MEP, and MEPH showed similar and lowest surface energy. CONCLUSION: Only FSil, FPSil, and MEPH maintained bond strength stability after thermocycling, with FPSil leading to less bond strength reduction, suggesting this protocol is more reliable for bonding resin cements to lithium disilicate glass ceramics.


Assuntos
Colagem Dentária , Cimentos de Resina , Humanos , Cimentos de Resina/química , Silanos/química , Colagem Dentária/métodos , Propriedades de Superfície , Condicionamento Ácido do Dente/métodos , Porcelana Dentária/química , Cerâmica/química , Teste de Materiais , Ácido Fluorídrico/química
3.
Braz. j. med. biol. res ; 54(2): e10107, 2021. graf
Artigo em Inglês | LILACS, Coleciona SUS | ID: biblio-1142578

RESUMO

Ketamine (KET) is an N-methyl-D-aspartate (NMDA) antagonist with rapid and long-lasting antidepressant effects, but how the drug shows its sustained effects is still a matter of controversy. The objectives were to evaluate the mechanisms for KET rapid (30 min) and long-lasting (15 and 30 days after) antidepressant effects in mice. A single dose of KET (2, 5, or 10 mg/kg, po) was administered to male Swiss mice and the forced swim test (FST) was performed 30 min, 15, or 30 days later. Imipramine (IMI, 30 mg/kg, ip), a tricyclic antidepressant drug, was used as reference. The mice were euthanized, separated into two time-point groups (D1, first day after KET injection; D30, 30 days later), and brain sections were processed for glycogen synthase kinase-3 (GSK-3), histone deacetylase (HDAC), brain-derived neurotrophic factor (BDNF), and glial fibrillary acidic protein (GFAP) immunohistochemical assays. KET (5 and 10 mg/kg) presented rapid and long-lasting antidepressant-like effects. As expected, the immunoreactivities for brain GSK-3 and HDAC decreased compared to control groups in all areas (striatum, DG, CA1, CA3, and mainly pre-frontal cortex, PFC) after KET injection. Increases in BDNF immunostaining were demonstrated in the PFC, DG, CA1, and CA3 areas at D1 and D30 time-points. GFAP immunoreactivity was also increased in the PFC and striatum at both time-points. In conclusion, KET changed brain BDNF and GFAP expressions 30 days after a single administration. Although neuroplasticity could be involved in the observed effects of KET, more studies are needed to explain the mechanisms for the drug's sustained antidepressant-like effects.


Assuntos
Animais , Masculino , Coelhos , Encéfalo/efeitos dos fármacos , Encéfalo/enzimologia , Fator Neurotrófico Derivado do Encéfalo/metabolismo , Ketamina/farmacologia , Antidepressivos/farmacologia , Astrócitos , Quinase 3 da Glicogênio Sintase , Modelos Animais de Doenças , Proteína Glial Fibrilar Ácida , Histona Desacetilases
4.
Braz J Med Biol Res ; 54(2): e10107, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33331415

RESUMO

Ketamine (KET) is an N-methyl-D-aspartate (NMDA) antagonist with rapid and long-lasting antidepressant effects, but how the drug shows its sustained effects is still a matter of controversy. The objectives were to evaluate the mechanisms for KET rapid (30 min) and long-lasting (15 and 30 days after) antidepressant effects in mice. A single dose of KET (2, 5, or 10 mg/kg, po) was administered to male Swiss mice and the forced swim test (FST) was performed 30 min, 15, or 30 days later. Imipramine (IMI, 30 mg/kg, ip), a tricyclic antidepressant drug, was used as reference. The mice were euthanized, separated into two time-point groups (D1, first day after KET injection; D30, 30 days later), and brain sections were processed for glycogen synthase kinase-3 (GSK-3), histone deacetylase (HDAC), brain-derived neurotrophic factor (BDNF), and glial fibrillary acidic protein (GFAP) immunohistochemical assays. KET (5 and 10 mg/kg) presented rapid and long-lasting antidepressant-like effects. As expected, the immunoreactivities for brain GSK-3 and HDAC decreased compared to control groups in all areas (striatum, DG, CA1, CA3, and mainly pre-frontal cortex, PFC) after KET injection. Increases in BDNF immunostaining were demonstrated in the PFC, DG, CA1, and CA3 areas at D1 and D30 time-points. GFAP immunoreactivity was also increased in the PFC and striatum at both time-points. In conclusion, KET changed brain BDNF and GFAP expressions 30 days after a single administration. Although neuroplasticity could be involved in the observed effects of KET, more studies are needed to explain the mechanisms for the drug's sustained antidepressant-like effects.


Assuntos
Antidepressivos/farmacologia , Fator Neurotrófico Derivado do Encéfalo/metabolismo , Encéfalo/efeitos dos fármacos , Encéfalo/enzimologia , Ketamina , Animais , Astrócitos , Modelos Animais de Doenças , Proteína Glial Fibrilar Ácida , Quinase 3 da Glicogênio Sintase , Histona Desacetilases , Ketamina/farmacologia , Masculino , Camundongos
5.
Oper Dent ; 40(3): 247-54, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25268041

RESUMO

This work tested CO2 laser as a glazing agent and investigated the effects of irradiation on the porosity, translucency, and mechanical properties of veneering porcelain. Sixty discs (diameter 3.5 × 2.0 mm) of veneering porcelain for Y-TZP frameworks (VM9, VITA Zahnfabrik) were sintered and had one of their faces mirror polished. The specimens were divided into six groups (n=10/group) according to surface treatment, as follows: no treatment-control; auto-glaze in furnace following manufacturer's instructions (G); and CO2 laser (45 or 50 W/cm(2)) applied for four or five minutes (L45/4, L45/5, L50/4, L50/5). Optical microscopy (Shimadzu, 100×) was conducted and the images were analyzed with Image J software for the determination of the following porosity parameters: area fraction, average size, and Feret diameter. The translucency parameter studied was masking ability, determined by color difference (ΔE) over black and white backgrounds (CM3370d, Konica Minolta). Microhardness and fracture toughness (indentation fracture) were measured with a Vickers indenter (HMV, Shimadzu). Contact atomic force microscopy (AFM) (50 × 50 µm(2), Nanoscope IIIA, Veeco) was performed at the center of one sample from each group, except in the case of L45/5. With regard to porosity and translucency parameters, auto-glazed and laser-irradiated specimens presented statistical similarity. The area fraction of the surface pores ranged between 2.4% and 5.4% for irradiated specimens. Group L50/5 presented higher microhardness when compared to the G group. The higher (1.1) and lower (0.8) values for fracture toughness (MPa.m(1/2)) were found in laser-irradiated groups (L50/4 and L45/4, respectively). AFM performed after laser treatment revealed changes in porcelain surface profile at a submicrometric scale, with the presence of elongated peaks and deep valleys.


Assuntos
Porcelana Dentária/efeitos da radiação , Facetas Dentárias , Lasers de Gás/uso terapêutico , Porcelana Dentária/normas , Análise do Estresse Dentário , Facetas Dentárias/normas , Dureza , Humanos , Microscopia de Força Atômica , Porosidade , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...