Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Vet Intern Med ; 35(6): 2920-2925, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34741540

RESUMO

Rate-adaptive single chamber pacemakers with accelerometer, closed loop stimulation (CLS), and remote monitoring functionality (Eluna 8 SR-T, Biotronik, SE & Co, Germany) were implanted in 3 miniature donkeys with third-degree atrioventricular block and syncope. After recovery, different pacemaker programming modes were tested at rest, during stress without physical exercise and during physical exercise. Pacing rates were compared to actual atrial rates and showed that CLS functionality allowed physiological heart rate adaptation. A transmitter installed in the stable provided wireless connection of the pacemaker to the internet. Home monitoring was activated which performed daily wireless transmission of pacemaker functional measurements to an online server allowing diagnosis of pathological arrhythmias and pacemaker malfunction from a distance. Closed loop stimulation and remote monitoring functionality resulted in nearly physiological rate adaptation and allowed remote "from-the-stable" patient follow-up.


Assuntos
Bloqueio Atrioventricular , Marca-Passo Artificial , Animais , Arritmias Cardíacas/veterinária , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/terapia , Bloqueio Atrioventricular/veterinária , Estimulação Cardíaca Artificial/veterinária , Equidae , Marca-Passo Artificial/veterinária , Síncope/diagnóstico , Síncope/terapia , Síncope/veterinária
2.
Contact Dermatitis ; 75(5): 276-284, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27538353

RESUMO

BACKGROUND: Octylisothiazolinone (OIT) is used as an antifungal agent by the leather industry. OBJECTIVES: To show sensitization to OIT from leather, and to highlight the potential implications when cross-reactivity between OIT and methylisothiazolinone (MI) is studied. METHODS: Two patients with allergic contact dermatitis caused by a leather belt and shoes, respectively, were patch tested with methylchloroisothiazolinone (MCI)/MI, MI, MCI, OIT, and benzisothiazolinone (BIT). High-performance liquid chromatography with ultraviolet detection (HPLC-UV) was used to detect isothiazolinone derivatives in leather goods. Additionally, files of OIT-sensitized patients, observed at the KU Leuven department during the period 1990-2015, were retrospectively analysed. RESULTS: Both patients had been primarily sensitized to OIT, but the diagnosis in one of them could be achieved only when a higher patch test concentration of OIT (1000 ppm pet.) was used. HPLC-UV confirmed the presence of OIT in their leather goods. Non-relevant sensitization to MI was noted in both cases. Four additional cases of OIT sensitization from leather could be retrieved from the KU Leuven database. CONCLUSIONS: Non-occupational sensitization to OIT from leather may occur. Patch test concentrations of >250 ppm pet. may be necessary for diagnosis, and to show cross-reactivity with MI. Safer use limits for OIT in the leather industry may be needed.


Assuntos
Dermatite Alérgica de Contato/etiologia , Dermatoses do Pé/etiologia , Fungicidas Industriais/efeitos adversos , Sapatos/efeitos adversos , Tiazóis/efeitos adversos , Abdome , Adulto , Cromatografia Líquida de Alta Pressão , Vestuário/efeitos adversos , Reações Cruzadas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Testes do Emplastro , Conservantes Farmacêuticos/efeitos adversos
3.
Contact Dermatitis ; 73(3): 142-9, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26256947

RESUMO

BACKGROUND: Methylisothiazolinone (MI) contact allergy is severely affecting consumers with allergic contact dermatitis, owing to its presence in cosmetics, household detergents, and water-based paints, in particular. Data on the true isothiazolinone concentrations in these products are scarce, and labelling may be incorrect. OBJECTIVES: To report on the MI concentrations in such products marketed in Belgium, in order to verify the accuracy of labelling (when applicable) and compliance with EU regulations. MATERIALS AND METHODS: Thirty cosmetics (18 leave-on and 12 rinse-off), eight detergents and four paints were analysed for MI by the use of high-performance liquid chromatography with ultraviolet detection. RESULTS: The analysed leave-on, and to a lesser extent the rinse-off, cosmetics, contained MI at concentrations far exceeding the permitted 100 ppm use concentration. Household detergents contained high concentrations of MI, and mislabelling occurred for both cosmetics and detergents. The (limited) data on paints are in line with the existing literature. CONCLUSION: Cosmetics and detergents may facilitate contact sensitization because of a (too) high MI concentration, and mislabelling may make its avoidance extremely difficult. Safer use concentrations and correct labelling should be ensured by adequate quality control.


Assuntos
Cosméticos/química , Detergentes/química , Pintura/análise , Conservantes Farmacêuticos/análise , Rotulagem de Produtos/normas , Tiazóis/análise , Bélgica , Dermatite Alérgica de Contato/etiologia , Humanos
6.
Phytochem Anal ; 22(4): 361-6, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21204153

RESUMO

INTRODUCTION: Phyllanthus amarus Schum. & Thonn. (Euphorbiaceae), already well known for its antiviral, antihyperglycaemic and antihepatotoxic effects, is also investigated for its antimalarial activity. The major constituent of the crude extract of the whole plant was isolated and identified in this research to be ellagic acid, for which antiplasmodial activity already has been reported. OBJECTIVE: Because of the potential of the plant and the interesting properties of ellagic acid, an analytical method can be useful for the standardisation of the extracts to allow further biological and pharmacological investigations. In order to obtain an easily performable and inexpensive method, an HPLC analysis was developed and validated. METHODOLOGY: The samples were dissolved in DMSO, ultrasonicated for 15 min, and diluted with 50% methanol. Analysis was performed using water and methanol containing 0.06% TFA and the peaks were detected at 254 nm. RESULTS: Ellagic acid showed a linear relationship in the range of 1.74-20.91 µg/mL and a single-point calibration was allowed. The method was shown to be precise with respect to time (RSD of 1.84%, 3 days, n = 6) and concentration (RSD of 2.54%, 3 levels, n = 6). The overall mean content of ellagic acid was 2.06%. A recovery experiment was performed and it showed an accuracy of 100.4%. CONCLUSION: Based on the obtained results, it can be concluded that the newly developed method is suitable for its purpose, namely the determination of ellagic acid in the crude extract of P. amarus.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Ácido Elágico/análise , Phyllanthus/química , Extratos Vegetais/química , Análise de Variância , República Democrática do Congo , Taninos Hidrolisáveis/metabolismo , Solventes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...