Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cochlear Implants Int ; 21(5): 260-268, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32397922

RESUMO

Objective: This study aims to assess the feasibility of autonomous cochlear implant (CI) fitting by adult CI recipients based on psychoacoustic self-testing and artificial intelligence (AI). Design: A feasibility study was performed on six adult CI recipients implanted with a Nucleus device. Two weeks after processor activation in the clinic, a 'self-fitting' session was organized in a supervised simulated home environment. The CI recipient performed pure tone audiometry and spectral discrimination tests as self-tests. The AI application FOX analysed the results and recommended a new map. The participants filled out a questionnaire and were tested again after 2 months of take-home experience. Results: Four out of six patients performed the self-tests without any help from the audiologist and four were fitted by FOX without any manual intervention. All patients were comfortable with the concept of self-testing and automated fitting. Patients acknowledged that at this stage the remote supervision of an audiologist remains essential. Conclusions: The study showed that audiological self-assessment and remote CI fitting with AI under the supervision of an audiologist is feasible, at least in a number of CI recipients. Currently, there are still some technical and regulatory challenges to be addressed before this can become routine practice.


Assuntos
Inteligência Artificial , Implantes Cocleares , Ajuste de Prótese/métodos , Autoteste , Telemedicina/métodos , Adulto , Idoso , Implante Coclear , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Psicoacústica , Resultado do Tratamento
2.
Folia Phoniatr Logop ; 70(2): 90-99, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30041186

RESUMO

PURPOSE: To overcome the potential tension between clinical and ecological validity in speech audiometric assessment by creating a new set of sentence materials with high linguistic validity for the Dutch-speaking area. METHODS: A linguistic "fingerprint" of modern spoken Dutch and Flemish served to generate a set of sentences recorded from 1 male and 1 female talker. The sentences were presented to 30 normal-hearing listeners in stationary speech noise at a signal-to-noise ratio (SNR) of -5 dB sound pressure level (SPL). A list design criterion was used to achieve perceptive homogeneity across the test lists, by scrambling lists of sentences of different syntactic types while controlling for linguistic complexity. The original set of test materials was narrowed down to 360 sentences, and list equivalency was evaluated at the audiological and linguistic levels. A psychometric curve was generated with a resolution of 2 dB based on a second group of 60 young normal-hearing native speakers of Dutch and Flemish. RESULTS: Sentence understanding showed an average repetition accuracy of 63.40% (SD 1.01) across the lists at an SNR of -5 dB SPL. No significant differences were found between the lists at the level of the individual listener. At the linguistic level, the sentence lists showed an equal distribution of phonological, morphological, and syntactic features. CONCLUSION: LiCoS combines the clinical benefit of acoustic control at the list level with the high ecological validity of linguistically representative test items. The new speech audiometric test is particularly appropriate to assess sentence understanding in individuals who would otherwise exhibit near-ceiling performance when tested with linguistically more simplified test stimuli. In combination with pure tone audiometric assessment, LiCoS provides valuable complementary information with respect to the functional hearing of patients.


Assuntos
Audiometria da Fala/métodos , Estimulação Acústica , Feminino , Transtornos da Audição/diagnóstico , Humanos , Masculino , Países Baixos , Valores de Referência , Acústica da Fala , Inteligibilidade da Fala , Gravação em Vídeo
3.
Cochlear Implants Int ; 18(4): 198-206, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28498083

RESUMO

OBJECTIVE: The software application FOX ('Fitting to Outcome eXpert') is an intelligent agent to assist in the programing of cochlear implant (CI) processors. The current version utilizes a mixture of deterministic and probabilistic logic which is able to improve over time through a learning effect. This study aimed at assessing whether this learning capacity yields measurable improvements in speech understanding. METHODS: A retrospective study was performed on 25 consecutive CI recipients with a median CI use experience of 10 years who came for their annual CI follow-up fitting session. All subjects were assessed by means of speech audiometry with open set monosyllables at 40, 55, 70, and 85 dB SPL in quiet with their home MAP. Other psychoacoustic tests were executed depending on the audiologist's clinical judgment. The home MAP and the corresponding test results were entered into FOX. If FOX suggested to make MAP changes, they were implemented and another speech audiometry was performed with the new MAP. RESULTS: FOX suggested MAP changes in 21 subjects (84%). The within-subject comparison showed a significant median improvement of 10, 3, 1, and 7% at 40, 55, 70, and 85 dB SPL, respectively. All but two subjects showed an instantaneous improvement in their mean speech audiometric score. DISCUSSION: Persons with long-term CI use, who received a FOX-assisted CI fitting at least 6 months ago, display improved speech understanding after MAP modifications, as recommended by the current version of FOX. This can be explained only by intrinsic improvements in FOX's algorithms, as they have resulted from learning. This learning is an inherent feature of artificial intelligence and it may yield measurable benefit in speech understanding even in long-term CI recipients.


Assuntos
Implantes Cocleares , Perda Auditiva/fisiopatologia , Ajuste de Prótese/métodos , Software , Percepção da Fala , Estimulação Acústica/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Audiometria da Fala , Criança , Feminino , Perda Auditiva/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
4.
Biomed Res Int ; 2016: 7249848, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27830152

RESUMO

In speech audiometric testing, hearing performance is typically measured by calculating the number of correct repetitions of a speech stimulus. We investigate to what extent the repetition accuracy of Dutch speech stimuli presented against a background noise is influenced by nonauditory processes. We show that variation in verbal repetition accuracy is partially explained by morpholexical and syntactic features of the target language. Verbs, prepositions, conjunctions, determiners, and pronouns yield significantly lower correct repetitions than nouns, adjectives, or adverbs. The reduced repetition performance for verbs and function words is probably best explained by the similarities in the perceptual nature of verbal morphology and function words in Dutch. For sentences, an overall negative effect of syntactic complexity on speech repetition accuracy was found. The lowest number of correct repetitions was obtained with passive sentences, reflecting the cognitive cost of processing a noncanonical sentence structure. Taken together, these findings may have important implications for the audiological practice. In combination with hearing loss, linguistic complexity may increase the cognitive demands to process sentences in noise, leading to suboptimal functional hearing in day-to-day listening situations. Using test sentences with varying degrees of syntactic complexity may therefore provide useful information to measure functional hearing benefits.


Assuntos
Percepção da Fala/fisiologia , Fala/fisiologia , Aprendizagem Verbal/fisiologia , Adulto , Cognição/fisiologia , Testes com Listas de Dissílabos/métodos , Feminino , Audição/fisiologia , Perda Auditiva/fisiopatologia , Humanos , Linguística/métodos , Masculino , Pessoa de Meia-Idade , Ruído , Testes de Discriminação da Fala/métodos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...