Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Echocardiography ; 41(6): e15861, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38853674

RESUMO

BACKGROUND: Transesophageal echocardiography (TEE) is primarily used to guide transcatheter structural heart interventions, such as tricuspid transcatheter edge-to-edge repair (TEER). Although TEE has a good safety profile, it is still an invasive imaging technique that may be associated with complications, especially when performed during long transcatheter procedures or on frail patients. The aim of this study was to assess TEE-related complications during tricuspid TEER. METHODS: This is a prospective study enrolling 53 patients who underwent tricuspid TEER for severe tricuspid regurgitation (TR). TEE-related complications were assessed clinically and divided into major (life-threatening, major bleeding requiring transfusions or surgery, organ perforation, and persistent dysphagia) and minor (perioral hypesthesia, < 24 h dysphagia/odynophagia, minor intraoral bleeding and hematemesis not requiring transfusion) RESULTS: The median age of the patient population was 79 years; 43.4% had severe, 39.6% massive, and 17.6% torrential TR. 62.3% of patients suffered from upper gastrointestinal disorders. Acute procedural success (APS) was achieved in 88.7% in a median device time of 36 min. A negative association was shown between APS and lead-induced etiology (r = -.284, p = .040), baseline TR grade (r = -.410, p = .002), suboptimal TEE view (r = -.349, p = .012), device time (r = -.234, p = .043), and leaflet detachment (r = -.496, p < .0001). We did not observe any clinical manifest major or minor TEE-related complications during the hospitalization. CONCLUSIONS: Our study reinforces the good safety profile and efficacy of TEE guidance during tricuspid TEER. Adequate preoperative management and intraprocedural precautions are mandatory in order to avoid serious complications. Furthermore, suboptimal intraprocedural TEE views are associated with lower TR reduction rates. HIGHLIGHTS: Transesophageal echocardiography is a crucial and safe technique for guiding transcatheter structural heart interventions. A mix of mid/deep esophageal and trans gastric views, as well as real-time 3D imaging is generally used to guide the procedure. Adequate preoperative management and intraprocedural precautions are mandatory in order to avoid serious problems. A shorter device time is associated with more rarely probe-related complications. Suboptimal intraprocedural TEE views are associated with lower TR reduction rates.


Assuntos
Ecocardiografia Transesofagiana , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Ecocardiografia Transesofagiana/métodos , Feminino , Masculino , Estudos Prospectivos , Insuficiência da Valva Tricúspide/cirurgia , Idoso , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/efeitos adversos , Resultado do Tratamento , Idoso de 80 Anos ou mais
2.
Front Cardiovasc Med ; 10: 1134828, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37123469

RESUMO

The most common organic etiology of mitral regurgitation is degenerative and consists of mitral valve prolapse (MVP). Volume overload because of mitral regurgitation is the most common complication of MVP. Advocating surgery before the consequences of volume overload become irreparable restores life expectancy, but carries a risk of mortality in patients who are often asymptomatic. On the other hand, the post-surgical outcome of symptomatic patients is dismal and life expectancy is impaired. In the present article, we aim to bridge the gap between these two therapeutic approaches, unifying the concepts of watchful waiting and early surgery in a "watchful surgery approach".

3.
J Clin Med ; 12(10)2023 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-37240669

RESUMO

Observing mitral or tricuspid valve disease in an athlete raises many considerations for the clinician. Initially, the etiology must be clarified, with causes differing depending on whether the athlete is young or a master. Notably, vigorous training in competitive athletes leads to a constellation of structural and functional adaptations involving cardiac chambers and atrioventricular valve systems. In addition, a proper evaluation of the athlete with valve disease is necessary to evaluate the eligibility for competitive sports and identify those requiring more follow-up. Indeed, some valve pathologies are associated with an increased risk of severe arrhythmias and potentially sudden cardiac death. Traditional and advanced imaging modalities help clarify clinical doubts, allowing essential information about the athlete's physiology and differentiating between primary valve diseases from those secondary to training-related cardiac adaptations. Remarkably, another application of multimodality imaging is evaluating athletes with valve diseases during exercise to reproduce the sport setting and better characterize the etiology and valve defect mechanism. This review aims to analyze the possible causes of atrioventricular valve diseases in athletes, focusing primarily on imaging applications in diagnosis and risk stratification.

4.
J Clin Med ; 12(9)2023 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-37176756

RESUMO

Functional mitral regurgitation (FMR) and tricuspid regurgitation (FTR) occur due to cardiac remodeling in the presence of structurally normal valve apparatus. Two main mechanisms are involved, distinguishing an atrial functional form (when annulus dilatation is predominant) and a ventricular form (when ventricular remodeling and dysfunction predominate). Both affect the prognosis of patients with heart failure (HF) across the entire spectrum of left ventricle ejection fraction (LVEF), including preserved (HFpEF), mildly reduced (HFmrEF), or reduced (HFrEF). Currently, data on the management of functional valve regurgitation in the various HF phenotypes are limited. This review summarizes the epidemiology, pathophysiology, and treatment of FMR and FTR within the different patterns of HF, as defined by LVEF.

5.
J Clin Med ; 12(5)2023 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-36902497

RESUMO

BACKGROUND: Cardiac computed tomography (CT) provides important insights into the geometrical configuration of the tricuspid valve (TV). The purpose of the present study was to assess the geometrical changes of TV in patients with functional tricuspid regurgitation (TR) using novel CT scan parameters and to correlate these findings with echocardiography. METHODS: This single-center study enrolled 86 patients undergoing cardiac CT and divided them into two groups according to the presence or not of severe TR (43 patients with TR ≥ 3+ and 43 controls). The measurements collected were as follows: TV annulus area and perimeter, septal-lateral and antero-posterior annulus diameters, eccentricity, distance between commissures, segment between the geometrical centroid and commissures, and the angles of commissures. RESULTS: We found a significant correlation between all annulus measurements and the grade of TR, except in regard to angles. TR ≥ 3+ patients had significantly larger TV annulus area and perimeter, larger septal-lateral, and antero-posterior annulus dimensions, as well as larger commissural distance and centroid-commissural distance. In patients with TR ≥ 3+ and controls, the eccentricity index predicted a circular shape and an oval shape of the annulus, respectively. CONCLUSIONS: These novel CT variables focusing on commissures increase the anatomical understanding of the TV apparatus and the TV geometrical changes in patients with severe functional TR.

6.
JACC Case Rep ; 5: 101685, 2023 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-36636505

RESUMO

Restrictive physiology, such as cardiac amyloidosis, compromises atrial and ventricular performance, often leading to "atrial" functional valvular regurgitation. While focusing on atrial functional tricuspid regurgitation we aimed at summarizing the pathophysiological characteristics of, and therapeutic options in, cardiac amyloidosis. (Level of Difficulty: Intermediate.).

7.
J Clin Med ; 11(19)2022 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-36233476

RESUMO

Background: The natural history of tricuspid valve regurgitation (TR) is characterized by poor prognosis and high in-hospital mortality when treated with isolated surgery. We report the preliminary echocardiographic and procedural results of a prospective cohort of symptomatic patients with high to prohibitive surgical risk and at least severe TR who underwent transcatheter edge-to-edge repair through the TriClipTM system. Methods: From June 2020 to March 2022, 27 consecutive patients were screened, and 13 underwent transcatheter TriClipTM repair. In-hospital, 30-day and six-month clinical and echocardiographic outcomes were collected. Results: Nine patients had severe, three massive and one baseline torrential TR. Sustained TR reduction of ≥1 grade was achieved in all patients, of which 90% reached a moderate TR or less. On transthoracic echocardiographic examination, there were significant reductions in vena contracta width (p < 0.001), effective regurgitant orifice area (p < 0.001) and regurgitant volume (p < 0.001) between baseline and hospital discharge. We also observed a significant reduction in tricuspid annulus diameter (p < 0.001), right ventricular basal diameter (p = 0.001) and right atrial area (p = 0.026). Conclusion: Treatment with the edge-to-edge TriClip device is safe and effective. The resulting echocardiographic improvements indicate tricuspid valve leaflet approximation does not just significantly reduce the grade of TR but also affects adjacent structures and improves right ventricular afterload adaptation.

8.
Radiol Med ; 127(12): 1355-1363, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36208384

RESUMO

PURPOSE: Chemoradiation is the standard treatment in patients with locally advanced non-small-cell lung cancer (LA-NSCLC), and thanks to the recent combination with immunotherapy, median survival has unexpectedly improved. This study aims to evaluate early changes in cardiac function after chemoradiotherapy (CRT) in LA-NSCLC by multimodal use of advanced imaging techniques. MATERIALS AND METHODS: This is a prospective, observational cohort study. At the beginning of combined treatment, screening tests including blood samples, electrocardiogram (ECG), echocardiographic examination (TTE), and cardiac magnetic resonance were performed in all patients with LA-NSCLC. ECG and cardiac marker assays were performed weekly during treatment. ECG and TTE were performed at month 1 (M1) and month 3 (M3) after the end of CRT. RESULTS: This preliminary analysis included thirty-four patients with a mean age of 69.5 years. The median follow-up was 27.8 months. 62% of patients were in stage IIIA. Radiation therapy was delivered with a median total dose of 60 Gy with conventional fractionation. All patients were treated with concurrent CRT, and 65% of cases were platinum-based therapy. Global longitudinal strain (GLS) and ejection fraction (EF) progressively decreased from baseline to M1 and M3. There was a strong correlation between GLS and EF reduction (at M1: p = 0.034; at M3: p = 0.018). Cardiac arrhythmias occurred in eight patients (23.5%) at a mean follow-up of 15.8 months after CRT. CONCLUSIONS: Reduction in GLS is an early sign occurring after the end of CRT for LA-NSCLC. Future studies are needed to identify variables that can increase the risk of cardiac events in this patient population to implement adequate damage prevention strategies.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Humanos , Idoso , Carcinoma Pulmonar de Células não Pequenas/terapia , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Neoplasias Pulmonares/terapia , Neoplasias Pulmonares/tratamento farmacológico , Estudos de Coortes , Quimiorradioterapia , Terapia Combinada
9.
Eur Heart J Open ; 2(1): oeab046, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35919657

RESUMO

Aims: This sub-study deriving from a multicentre Italian register [Deformation Imaging by Strain in Chronic Heart Failure Over Sacubitril-Valsartan: A Multicenter Echocardiographic Registry (DISCOVER)-ARNI] investigated whether sacubitril/valsartan in addition to optimal medical therapy (OMT) could reduce the rate of implantable cardioverter-defibrillator (ICD) indications for primary prevention in heart failure with reduced ejection fraction (HFrEF) according to European guidelines indications, and its potential predictors. Methods and results: In this observational study, consecutive patients with HFrEF eligible for sacubitril/valsartan from 13 Italian centres were included. Lack of follow-up or speckle tracking data represented exclusion criteria. Demographic, clinical, biochemical, and echocardiographic data were collected at baseline and after 6 months from sacubitril/valsartan initiation. Of 351 patients, 225 (64%) were ICD carriers and 126 (36%) were not ICD carriers (of whom 13 had no indication) at baseline. After 6 months of sacubitril/valsartan, among 113 non-ICD carriers despite having baseline left ventricular (LV) ejection fraction (EF) ≤ 35% and New York Heart Association (NYHA) class = II-III, 69 (60%) did not show ICD indications; 44 (40%) still fulfilled ICD criteria. Age, atrial fibrillation, mitral regurgitation > moderate, left atrial volume index (LAVi), and LV global longitudinal strain (GLS) significantly varied between the groups. With receiver operating characteristic curves, age ≥ 75 years, LAVi ≥ 42 mL/m2 and LV GLS ≥-8.3% were associated with ICD indications persistence (area under the curve = 0.65, 0.68, 0.68, respectively). With univariate and multivariate analysis, only LV GLS emerged as significant predictor of ICD indications at follow-up in different predictive models. Conclusions: Sacubitril/valsartan may provide early improvement of NYHA class and LVEF, reducing the possible number of implanted ICD for primary prevention in HFrEF. Baseline reduced LV GLS was a strong marker of ICD indication despite OMT. Early therapy with sacubitril/valsartan may save infective/haemorrhagic risks and unnecessary costs deriving from ICDs.

10.
J Clin Med ; 11(10)2022 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-35628951

RESUMO

BACKGROUND: Computed tomography (CT) is the recommended imaging technique for defining the anatomical suitability for current transcatheter technologies and planning tricuspid valve (TV) intervention. The aim of the Tricuspid Regurgitation IMAging (TRIMA) study was to assess the geometrical characteristics of the TV complex using novel CT parameters. METHODS: This prospective, single-center study enrolled 22 consecutive patients with severe tricuspid regurgitation, who underwent a cardiac CT study dedicated to the right chambers. The following variables were obtained: annulus area and perimeter, septal-lateral and antero-posterior diameters, tenting height, and anatomical regurgitant orifice area. Moreover, the following novel annular parameters were assessed: distance between commissures, distance between TV centroid and commissures, and angles between centroid and commissures. RESULTS: A significant phasic variability during the cardiac cycle existed for all variables except for eccentricity, angles, and distance between the postero-septal and antero-posterior commissure and distance between the centroid and antero-posterior commissure. There was a significant relationship between the TV annulus area and novel annular parameters, except for annular angles. Additionally, novel annular variables were found to predict the annulus area. CONCLUSIONS: These novel additional variables may provide an initial platform from which the complexity of the TV annular morphology can continue to be better understood for further improving transcatheter therapies.

12.
Front Cardiovasc Med ; 8: 778445, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34869692

RESUMO

Nowadays, severe symptomatic tricuspid regurgitation (TR) affects millions of persons worldwide. However, the benefit of surgical correction of isolated secondary TR remains controversial because of the increased risk of periprocedural mortality and morbidity. In recent years, novel transcatheter tricuspid valve interventions (TTVI) were developed to treat TR, so that TTVI is currently considered in symptomatic, inoperable, anatomically eligible patients. TTVI can be divided into these five domains: edge-to-edge leaflet repair, tricuspid annuloplasty, caval implants, spacer, and total valve replacement. Each transcatheter intervention needs specific imaging protocols for assessing the anatomical feasibility and consequentially predicting the procedural success. This review summarizes the available multimodality imaging tools for screening patients with TR, and identifies anatomical characteristics to choose the best option for the patient.

13.
Heart Fail Clin ; 17(4): 607-618, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34511209

RESUMO

In heart failure with reduced ejection fraction, the interventional landscape has recently expanded. New transcatheter approaches are emerging for both mitral and tricuspid secondary (functional) regurgitation. Transcatheter therapies for mitral and tricuspid valve require a more tailored approach than for the aortic valve, because of more heterogeneous clinical scenarios, anatomic features, and mechanisms of valvular lesions.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Cateterismo Cardíaco , Insuficiência Cardíaca/cirurgia , Humanos , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia
14.
Front Cardiovasc Med ; 8: 704762, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34485406

RESUMO

In past cardiovascular medicine, the attention to the left ventricle-identified as the only indicator and determinant of healthy or unhealthy cardiac conditions- has systematically hidden the role of the left atrium (LA). The recent advances in cardiovascular imaging have provided a better understanding of LA anatomy, physiology, and pathology, making us realize that this functional structure is far from being an innocent spectator. We now know that the LA's mechanical and neuro-hormonal properties play a relevant part in several cardiovascular diseases, including atrial fibrillation, ischemic heart disease, valvular heart disease, and heart failure. The present review aims to describe the role of LA in the specific setting of heart failure. We provide currently available information on LA structure and function and summarize its role as a determinant of symptoms, prognosis, and potential therapeutic target in heart failure patients.

17.
Int J Cardiol ; 227: 106-113, 2017 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-27855288

RESUMO

BACKGROUND: Severe primary mitral regurgitation (MR) carries a significant incidence of mortality and morbidity. Though a number of prognostic factors have been identified, the best timing for mitral valve repair is still debated. We assessed the role of Left Atrial Volume Indexed (LAVI) as predictor of adverse events after mitral valve surgery. METHODS: 134 patients with severe MR were studied with a follow-up of 42±16months. Endpoints were Post-Operative Atrial Fibrillation (POAF), atrial and ventricular remodeling (LARR/LVRR) and correlation with outcome. POAF was defined as AF occurring within 2weeks and late AF (LAF) more than 2weeks after surgery. LARR was defined as LAVI reduction ≥15% and LVRR as any reduction of ventricular mass after surgery. RESULTS: Forty-one patients experienced POAF, 26 had LAF. Pre-operative LAVI was an independent risk factor for POAF (OR 1.03, CI [1.00-1.06], p=0.01), LAF (OR 1.03, CI [1.00-1.06], p=0.02), LARR and LVRR (OR 1.04, CI [1.01-1.07], p=0.002, respectively). LARR was found in 75 patients, while LVRR in 111. Patients with heart remodeling had less incidence of LAF and cardiac adverse events, better diastolic function and improved their NYHA class after surgery. CONCLUSIONS: LAVI should be given more weight into decision making for patients with MR as it predicts POAF and LAF and reverse atrial and ventricular remodeling, both associated to long-term outcome.


Assuntos
Átrios do Coração/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/tendências , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Cuidados Pré-Operatórios/tendências , Idoso , Ecocardiografia/tendências , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão
18.
J Electrocardiol ; 49(5): 691-5, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27498055

RESUMO

BACKGROUND: In 1990 the American Heart Association (AHA) established a standard 0.05 to 150Hz bandwidth for the routine recording of 12-lead electrocardiograms (ECGs). However, subsequent studies have indicated a very high prevalence of deviations from the recommended cutoffs. OBJECTIVE: This prospective observational study investigates the impact of 40Hz compared to 150Hz high-frequency cutoffs on ECG quality and clinical interpretation in a single-center surgical outpatient population. METHODS: 1582 consecutive adult patients underwent two standard 12-lead ECG tracings using different high-frequency cutoffs (40Hz and 150Hz). Two blinded cardiologists randomly reviewed and interpreted the recordings according to pre-defined parameters (PR and ST segment, Q and T wave abnormalities). An arbitrary score, ranging from 1 to 3, was established to evaluate the perceived quality of the recordings and the non-interpretable ECGs were noted. The tracings were then matched to compare interpretations between 40 and 150Hz filters. RESULTS: A 40Hz high-frequency cutoff resulted in an increased rate of optimal quality ECGs compared to the 150Hz cutoff (93.4% vs 54.6%; p<0.001) and a lower rate of non-interpretable traces (0.25% vs 4.80%; p<0.001). Analyzing the morphologic parameters, no significant differences between the filter settings were found, except for a higher incidence of the J-point elevation in the 40Hz high-frequency cutoff (p=0.007) and a higher incidence of left ventricular hypertrophy in the 150Hz high-frequency cutoff (7.4% vs 5.4%, p<0.001). The latter was noted only in ECGs with borderline QRS amplitudes (between 3.3 and 3.7mV; p<0.001). CONCLUSION: Despite current recommendations, the large deviation from standard high-frequency cutoff in clinical practice does not seem to significantly affect ECG clinical interpretation and a 40Hz high-frequency cutoff of the band-pass filtering may be acceptable in a low risk population, allowing for a better quality of tracings.


Assuntos
Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiologia , Eletrocardiografia/instrumentação , Eletrocardiografia/estatística & dados numéricos , Processamento de Sinais Assistido por Computador , Adulto , Assistência Ambulatorial/estatística & dados numéricos , Diagnóstico por Computador , Feminino , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Período Pré-Operatório , Prevalência , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Método Simples-Cego
20.
J Cardiovasc Echogr ; 26(1): 16-18, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-28465954

RESUMO

Ostium primum defect is a congenital malformation involving atrial septum contiguous with atrioventricular valve annulus; it is accompanied by abnormalities in the development of the endocardial cushions, often resulting in associated atrioventricular valves malformations. Few cases have been reported in adulthood because these patients frequently come to medical attention at an earlier age when symptoms such as dyspnea, fatigue, cyanosis, and tendency to underweight occur. Various factors affect the timing of clinical presentation, but the most important is the degree of mitral/tricuspid insufficiency; when valve regurgitation remains moderate, the appearance of symptoms may be delayed for decades. In adult patients, deterioration of clinical status and death are mainly due to the development of arrhythmias or heart block. We present the case of a 67-year-old patient, without previous cardiovascular events, with a new onset of atrial fibrillation, who developed dyspnea and fatigue; echocardiography showed a large interatrial defect localized in the basal portion of the septum, associated with anterior mitral valve cleft and moderate regurgitation. The patient underwent surgical closure of the defect (intraoperatory measures 1,9 × 3 cm) with autologous pericardium patch; a permanent epicardial pacemaker was implanted for the development of complete atrioventricular block in the early postoperative period.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...