Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Air Waste Manag Assoc ; 70(2): 158-179, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31403397

RESUMO

Increases in large wildfire frequency and intensity and a longer fire season in the western United States are resulting in a significant increase in air pollution, including concentrations of PM2.5 (particulate matter <2.5 µm in aerodynamic diameter) that pose significant health risks to nearby communities. During wildfires, government agencies monitor PM2.5 mass concentrations providing information and actions needed to protect affected communities; this requires continuously measuring instruments. This study assessed the performance of seven candidate instruments: (1) Met One Environmental beta attenuation monitor (EBAM), (2) Met One ES model 642 (ES642), (3) Grimm Environmental Dust Monitor 164 (EDM), (4) Thermo ADR 1500 (ADR), (5) TSI DRX model 8543 (DRX), (6) Dylos 1700 (Dylos), and (7) Purple Air II (PA-II) in comparison with a BAM 1020 (BAM) reference instrument. With the exception of the EBAM, all candidates use light scattering to determine PM2.5 mass concentrations. Our comparison study included environmental chamber and field components, with two of each candidate instrument operating next to the reference instrument. The chamber component involved 6 days of comparisons for biomass combustion emissions. The field component involved operating all instruments in an air monitoring station for 39.5 days with hourly average relative humidity (RH) ranging from 19% to 98%. Goals were to assess instrument precision and accuracy and effects of RH, elemental carbon (EC), and organic carbon (OC) concentrations. All replicate candidate instruments showed high hourly correlations (R2 ≥ 0.80) and higher daily average correlations (R2 ≥ 0.90), where all instruments correlated well (R2 ≥ 0.80) with the reference. The DRX and Purple Air overestimated PM2.5 mass concentrations by a factor of ~two. Differences between candidates and reference were more pronounced at higher PM2.5 concentrations. All optical instruments were affected by high RH and by the EC/OC ratio. Equations to convert candidate instruments data to FEM BAM type data are provided to enhance the usability of data from candidate instruments.Implications: This study tested the performance of seven candidate PM2.5 mass concentration measuring instruments in two settings - environmental chamber and field. The instruments were tested to determine their suitability for use during biomass combustion events and the effects of RH, PM mass concentrations, and concentrations of EC and OC on their performance. The accuracy and precision of each monitor and effect of RH, PM concentration, EC and OC concentrations are varied. The data show that most of these candidate instruments are suitable for measuring PM2.5 concentration during biomass combustions with a proper correction factor for each instrument type.


Assuntos
Poluentes Atmosféricos/análise , Monitoramento Ambiental/instrumentação , Fumaça/análise , Poluição do Ar/análise , Monitoramento Ambiental/métodos
2.
Chem Phys Lipids ; 213: 48-61, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29580834

RESUMO

Niemann-Pick disease type C2 is a lipid storage disorder in which mutations in the NPC2 protein cause accumulation of lipoprotein-derived cholesterol in late endosomes and lysosomes (LE/LYSs). Whether cholesterol delivered by other means to NPC2 deficient cells also accumulates in LE/LYSs is currently unknown. We show that the close cholesterol analog dehydroergosterol (DHE), when delivered to the plasma membrane (PM) accumulates in LE/LYSs of human fibroblasts lacking functional NPC2. We measured two different time scales of sterol diffusion; while DHE rich LE/LYSs moved by slow anomalous diffusion in disease cells (D ∼ 4.6∙10-4 µm2/sec; α∼0.76), a small pool of sterol could exchange rapidly with D ∼ 3 µm2/s between LE/LYSs, as shown by fluorescence recovery after photobleaching (FRAP). By quantitative lipid mass spectrometry we found that esterification of 13C-labeled cholesterol but not of DHE is reduced 10-fold in disease fibroblasts compared to control cells. Internalized NPC2 rescued the sterol storage phenotype and strongly expanded the dynamic sterol pool seen in FRAP experiments. Together, our study shows that cholesterol esterification and trafficking of sterols between the PM and LE/LYSs depends on a functional NPC2 protein. NPC2 likely acts inside LE/LYSs from where it increases non-vesicular sterol exchange with other organelles.


Assuntos
Proteínas de Transporte/metabolismo , Membrana Celular/metabolismo , Endossomos/metabolismo , Ergosterol/análogos & derivados , Glicoproteínas/metabolismo , Transporte Biológico , Isótopos de Carbono/química , Linhagem Celular , Colesterol/química , Colesterol/metabolismo , Retículo Endoplasmático/metabolismo , Ergosterol/química , Ergosterol/metabolismo , Fibroblastos/citologia , Fibroblastos/metabolismo , Recuperação de Fluorescência Após Fotodegradação , Humanos , Lisossomos/metabolismo , Microscopia de Fluorescência , Imagem com Lapso de Tempo , Proteínas de Transporte Vesicular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...