1.
Heart Rhythm O2 ; 5(8): 551-560, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39263609

RESUMO

Background: Leadless cardiac resynchronization therapy (CRT) is an emerging heart failure treatment. An implanted electrode delivers lateral or septal endocardial left ventricular (LV) pacing (LVP) upon detection of a right ventricular (RV) pacing stimulus from a coimplanted device, thus generating biventricular pacing (BiVP). Electrical efficacy data regarding this therapy, particularly leadless LV septal pacing (LVSP) for potential conduction system capture, are limited. Objectives: The purpose of this study was to evaluate the acute performance of leadless CRT using electrocardiographic imaging (ECGi) and assess the optimal pacing modality (OPM) of LVSP on the basis of RV and LV activation. Methods: Ten WiSE-CRT recipients underwent an ECGi study testing: RV pacing, BiVP, LVP only, and LVP with an optimized atrioventricular delay (LV-OPT). BiV, LV, and RV activation times (shortest time taken to activate 90% of the ventricles [BIVAT-90], shortest time taken to activate 95% of the LV, and shortest time taken to activate 90% of the RV) plus LV and BiV dyssynchrony index (standard deviation of LV activation times and standard deviation of all activation times) were calculated from reconstructed epicardial electrograms. The individual OPM yielding the greatest improvement from baseline was determined. Results: BiVP generated a 23.7% improvement in BiVAT-90 (P = .002). An improvement of 43.3% was observed at the OPM (P = .0001), primarily through reductions in shortest time taken to activate 90% of the RV. At the OPM, BiVAT-90 improved in patients with lateral (43.3%; P = .0001; n = 5) and septal (42.4%; P = .009; n = 5) LV implants. The OPM varied by individual. LVP and LV-OPT were mostly superior in patients with LVSP, and in those with sinus rhythm and left bundle branch block (n = 4). Conclusion: Leadless CRT significantly improves acute ECGi-derived activation and dyssynchrony metrics. Using an individualized OPM improves efficacy in selected patients. Effective LVSP is feasible, with fusion pacing at LV-OPT mitigating the potential deleterious effects on RV activation.

2.
Heart Rhythm ; 2024 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-39209224

RESUMO

BACKGROUND: Leadless left ventricular (LV) endocardial pacing is an emerging cardiac resynchronization therapy (CRT) technology. Predictors of response to leadless CRT are poorly understood. Implanting the LV endocardial pacing electrode in sites with increased electrical latency (Q-LV) may improve response rates. OBJECTIVE: The purpose of this study was to examine the association between Q-LV and echocardiographic remodeling response to leadless CRT delivered with the WiSE-CRT system. METHODS: A post hoc analysis (n = 122) of the SOLVE-CRT trial examined the relationship between LV pacing site Q-LV with rate of left ventricular end-systolic volume (LVESV) reduction >15% at 6 months. Multivariable regression analysis, adjusting for age, sex, previous CRT nonresponse, cardiomyopathy etiology, QRS morphology, and QRS duration was performed, followed by receiver operating characteristic analysis and analysis of variance by Q-LV quartile. A subgroup analysis of the ischemic cardiomyopathy cohort was undertaken. RESULTS: Complete Q-LV data were available for 122 of 153 patients (80%) in the active arms SOLVE-CRT. Overall, the 6-month LVESV response rate was 46%. Logistic regression identified Q-LV as an independent response predictor with borderline significance (adjusted odds ratio 1.015; P = .05). Analysis by Q-LV quartile demonstrated a significant improvement in response rate in quartile 4 (longest Q-LV 64%) compared to quartile 1 (shortest Q-LV 28%) (P <.01). This association was primarily driven by strong Q-LV-response correlation in patients with ischemic cardiomyopathy, demonstrated by subgroup logistic regression (adjusted odds ratio 1.034; P = .004). CONCLUSION: Increased Q-LV was associated with improved reverse remodeling following leadless CRT. Targeting LV endocardial sites of high Q-LV may deliver additional benefit compared to empirical LV electrode implantation.

3.
Artigo em Inglês | MEDLINE | ID: mdl-39136365

RESUMO

Atrial fibrillation (AF) is the most common sustained arrhythmia worldwide and remains a major cause of morbidity and mortality. Unfortunately, a significant proportion of patients have persistent AF, for which conventional catheter ablation is less effective. However, convergent ablation has emerged in recent years as a hybrid treatment targeting both the epicardium and endocardium in a multidisciplinary joint cardiothoracic and electrophysiology procedure, with promising efficacy outcomes in recent studies. This treatment is increasingly being performed in the United Kingdom. This review article discusses the rationale and evidence behind convergent ablation, along with factors that need to be considered when setting up a successful ablation service.

4.
J Am Heart Assoc ; 13(12): e035279, 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38879456

RESUMO

BACKGROUND: Studies have reported that female sex predicts superior cardiac resynchronization therapy (CRT) response. One theory is that this association is related to smaller female heart size, thus increased relative dyssynchrony at a given QRS duration (QRSd). Our objective was to investigate the mechanisms of sex-specific CRT response relating to heart size, relative dyssynchrony, cardiomyopathy type, QRS morphology, and other patient characteristics. METHODS AND RESULTS: This is a post hoc analysis of the MORE-CRT MPP (More Response on Cardiac Resynchronization Therapy with Multipoint Pacing)  trial (n=3739, 28% women), with a subgroup analysis of patients with nonischemic cardiomyopathy and left bundle-branch block (n=1308, 41% women) to control for confounding characteristics. A multivariable analysis examined predictors of response to 6 months of conventional CRT, including sex and relative dyssynchrony, measured by QRSd/left ventricular end-diastolic volume (LVEDV). Women had a higher CRT response rate than men (70.1% versus 56.8%, P<0.0001). In subgroup analysis, regression analysis of the nonischemic cardiomyopathy left bundle-branch block subgroup identified QRSd/LVEDV, but not sex, as a modifier of CRT response (P<0.0039). QRSd/LVEDV was significantly higher in women (0.919) versus men (0.708, P<0.001). CRT response was 78% for female patients with QRSd/LVEDV greater than the median value, compared with 68% with QRSd/LVEDV less than the median value (P=0.012). The association between CRT response and QRSd/LVEDV was strongest at QRSd <150 ms. CONCLUSIONS: In the nonischemic cardiomyopathy left bundle-branch block population, increased relative dyssynchrony in women, who have smaller heart sizes than their male counterparts, is a driver of sex-specific CRT response, particularly at QRSd <150 ms. Women may benefit from CRT at a QRSd <130 ms, opening the debate on whether sex-specific QRSd cutoffs or QRS/LVEDV measurement should be incorporated into clinical guidelines.


Assuntos
Bloqueio de Ramo , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/métodos , Feminino , Masculino , Idoso , Fatores Sexuais , Pessoa de Meia-Idade , Resultado do Tratamento , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/diagnóstico , Bloqueio de Ramo/terapia , Bloqueio de Ramo/fisiopatologia , Cardiomiopatias/fisiopatologia , Cardiomiopatias/terapia , Cardiomiopatias/diagnóstico , Tamanho do Órgão , Função Ventricular Esquerda/fisiologia , Volume Sistólico/fisiologia , Coração/fisiopatologia , Eletrocardiografia
5.
Arch Dis Child ; 109(8): 654-658, 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-38724065

RESUMO

BACKGROUND: Idiopathic intracranial hypertension (IIH) is a potentially disabling condition. There is a lack of evidence and national guidance on how to diagnose and treat paediatric IIH, leading to variation in clinical practice. We conducted a national Delphi consensus via the Children's Headache Network to propose a best-practice diagnostic and therapeutic pathway. METHODS: The Delphi process was selected as the most appropriate methodology for examining current opinion among experts in the UK. 104 questions were considered by 66 healthcare professionals, addressing important aspects of IIH care: assessment, diagnosis, treatment, follow-up and surveillance. General paediatricians, paediatric neurologists, ophthalmologists, opticians, neuroradiologists and neurosurgeons with a clinical interest or experience in IIH, were invited to take part. RESULTS: The Delphi process consisted of three rounds comprising 104 questions (round 1, 67; round 2, 24; round 3 (ophthalmological), 13) and was completed between March 2019 and August 2021. There were 54 and 65 responders in the first and second rounds, respectively. The Delphi was endorsed by the Royal College of Ophthalmologists, which engaged 59 ophthalmologists for round 3. CONCLUSIONS: This UK-based Delphi consensus process reached agreement for the management of paediatric IIH and has been endorsed by the Children's Headache Network and more broadly, the British Paediatric Neurology Association. It provides a basis for a pragmatic clinical approach. The recommendations will help to improve clinical care while minimising under and over diagnosis.


Assuntos
Consenso , Técnica Delphi , Pseudotumor Cerebral , Humanos , Criança , Pseudotumor Cerebral/diagnóstico , Pseudotumor Cerebral/terapia , Pseudotumor Cerebral/complicações , Adolescente , Reino Unido , Guias de Prática Clínica como Assunto
6.
Heart Rhythm ; 21(6): 919-928, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38354872

RESUMO

BACKGROUND: Machine learning (ML) models have been proposed to predict risk related to transvenous lead extraction (TLE). OBJECTIVE: The purpose of this study was to test whether integrating imaging data into an existing ML model increases its ability to predict major adverse events (MAEs; procedure-related major complications and procedure-related deaths) and lengthy procedures (≥100 minutes). METHODS: We hypothesized certain features-(1) lead angulation, (2) coil percentage inside the superior vena cava (SVC), and (3) number of overlapping leads in the SVC-detected from a pre-TLE plain anteroposterior chest radiograph (CXR) would improve prediction of MAE and long procedural times. A deep-learning convolutional neural network was developed to automatically detect these CXR features. RESULTS: A total of 1050 cases were included, with 24 MAEs (2.3%) . The neural network was able to detect (1) heart border with 100% accuracy; (2) coils with 98% accuracy; and (3) acute angle in the right ventricle and SVC with 91% and 70% accuracy, respectively. The following features significantly improved MAE prediction: (1) ≥50% coil within the SVC; (2) ≥2 overlapping leads in the SVC; and (3) acute lead angulation. Balanced accuracy (0.74-0.87), sensitivity (68%-83%), specificity (72%-91%), and area under the curve (AUC) (0.767-0.962) all improved with imaging biomarkers. Prediction of lengthy procedures also improved: balanced accuracy (0.76-0.86), sensitivity (75%-85%), specificity (63%-87%), and AUC (0.684-0.913). CONCLUSION: Risk prediction tools integrating imaging biomarkers significantly increases the ability of ML models to predict risk of MAE and long procedural time related to TLE.


Assuntos
Remoção de Dispositivo , Aprendizado de Máquina , Humanos , Masculino , Feminino , Remoção de Dispositivo/métodos , Medição de Risco/métodos , Idoso , Desfibriladores Implantáveis/efeitos adversos , Estudos Retrospectivos , Veia Cava Superior/diagnóstico por imagem , Pessoa de Meia-Idade , Redes Neurais de Computação , Biomarcadores
7.
Circ Arrhythm Electrophysiol ; 17(3): e012446, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38258308

RESUMO

BACKGROUND: Antimicrobial envelopes reduce the incidence of cardiac implantable electronic device infections, but their cost restricts routine use in the United Kingdom. Risk scoring could help to identify which patients would most benefit from this technology. METHODS: A novel risk score (BLISTER [Blood results, Long procedure time, Immunosuppressed, Sixty years old (or younger), Type of procedure, Early re-intervention, Repeat procedure]) was derived from multivariate analysis of factors associated with cardiac implantable electronic device infection. Diagnostic utility was assessed against the existing PADIT score (Prior procedure, Age, Depressed renal function, Immunocompromised, Type of procedure) in both standard and high-risk external validation cohorts, and cost-utility models examined different BLISTER and PADIT score thresholds for TYRX (Medtronic; Minneapolis, MN) antimicrobial envelope allocation. RESULTS: In a derivation cohort (n=7383), cardiac implantable electronic device infection occurred in 59 individuals within 12 months of a procedure (event rate, 0.8%). In addition to the PADIT score constituents, lead extraction (hazard ratio, 3.3 [95% CI, 1.9-6.1]; P<0.0001), C-reactive protein >50 mg/L (hazard ratio, 3.0 [95% CI, 1.4-6.4]; P=0.005), reintervention within 2 years (hazard ratio, 10.1 [95% CI, 5.6-17.9]; P<0.0001), and top-quartile procedure duration (hazard ratio, 2.6 [95% CI, 1.6-4.1]; P=0.001) were independent predictors of infection. The BLISTER score demonstrated superior discriminative performance versus PADIT in the standard risk (n=2854, event rate: 0.8%, area under the curve, 0.82 versus 0.71; P=0.001) and high-risk validation cohorts (n=1961, event rate: 2.0%, area under the curve, 0.77 versus 0.69; P=0.001), and in all patients (n=12 198, event rate: 1%, area under the curve, 0.8 versus 0.75, P=0.002). In decision-analytic modeling, the optimum scenario assigned antimicrobial envelopes to patients with BLISTER scores ≥6 (10.8%), delivering a significant reduction in infections (relative risk reduction, 30%; P=0.036) within the National Institute for Health and Care Excellence cost-utility thresholds (incremental cost-effectiveness ratio, £18 446). CONCLUSIONS: The BLISTER score (https://qxmd.com/calculate/calculator_876/the-blister-score-for-cied-infection) was a valid predictor of cardiac implantable electronic device infection, and could facilitate cost-effective antimicrobial envelope allocation to high-risk patients.


Assuntos
Anti-Infecciosos , Desfibriladores Implantáveis , Cardiopatias , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Humanos , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Cardiopatias/complicações , Antibacterianos/uso terapêutico , Fatores de Risco , Eletrônica , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/prevenção & controle , Marca-Passo Artificial/efeitos adversos
8.
medRxiv ; 2023 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-38106113

RESUMO

Background: Studies have reported that female sex predicts superior cardiac resynchronization therapy (CRT) response. One theory is that this association is related to smaller female heart size, thus increased "relative dyssynchrony" at given QRS durations (QRSd). Objective: To investigate the mechanisms of sex-specific CRT response relating to heart size, relative dyssynchrony, cardiomyopathy type, QRS morphology, and other patient characteristics. Methods: A post-hoc analysis of the MORE-CRT MPP trial (n=3739, 28% female), with a sub-group analysis of patients with non-ischaemic cardiomyopathy (NICM) and left bundle branch block (LBBB) (n=1308, 41% female) to control for confounding characteristics. A multivariable analysis examined predictors of response to 6 months of conventional CRT, including sex and relative dyssynchrony, measured by QRSd/LVEDV (left ventricular end-diastolic volume). Results: Females had a higher CRT response rate than males (70.1% vs. 56.8%, p<0.0001). Subgroup analysis: Regression analysis of the NICM LBBB subgroup identified QRSd/LVEDV, but not sex, as a modifier of CRT response (p<0.0039). QRSd/LVEDV was significantly higher in females (0.919) versus males (0.708, p<0.001). CRT response was 78% for female patients with QRSd/LVEDV>median value, compared to 68% < median value (p=0.012). Association between CRT response and QRSd/LVEDV was strongest at QRSd<150ms. Conclusions: In the NICM LBBB population, increased relative dyssynchrony in females, who have smaller heart sizes than their male counterparts, is a driver of sex-specific CRT response, particularly at QRSd <150ms. Females may benefit from CRT at a QRSd <130ms, opening the debate on whether sex-specific QRSd cut-offs or QRS/LVEDV measurement should be incorporated into clinical guidelines.

9.
Artigo em Inglês | MEDLINE | ID: mdl-37870689

RESUMO

Conduction system pacing (CSP) has the potential to achieve physiological-paced activation by pacing the ventricular conduction system. Before CSP is adopted in standard clinical practice, large, randomised, and multi-centre trials are required to investigate CSP safety and efficacy compared to standard biventricular pacing (BVP). Furthermore, there are unanswered questions about pacing thresholds required to achieve optimal pacing delivery while preventing device battery draining, and about which patient groups are more likely to benefit from CSP rather than BVP. In silico studies have been increasingly used to investigate mechanisms underlying changes in cardiac function in response to pathologies and treatment. In the context of CSP, they have been used to improve our understanding of conduction system capture to optimise CSP delivery and battery life, and noninvasively compare different pacing methods on different patient groups. In this review, we discuss the in silico studies published to date investigating different aspects of CSP delivery.

11.
J Cardiovasc Electrophysiol ; 34(12): 2590-2598, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37814470

RESUMO

BACKGROUND: The Wireless Stimulation Endocardially for CRT (WiSE-CRT) system is a novel technology used to treat patients with dyssynchronous heart failure (HF) by providing leadless cardiac resynchronization therapy (CRT). Observational studies have demonstrated its safety and efficacy profile, however, the treatment cost-effectiveness has not previously been examined. METHODS: A cost-effectiveness evaluation of the WiSE-CRT System was performed using a cohort-based economic model adopting a "proportion in state" structure. In addition to the primary analysis, scenario analyses and sensitivity analyses were performed to test for uncertainty in input parameters. Outcomes were quantified in terms of quality-adjusted life year (QALY) differences. RESULTS: The primary analysis demonstrated that treatment with the WiSE-CRT system is likely to be cost-effective over a lifetime horizon at a QALY reimbursement threshold of £20 000, with a net monetary benefit (NMB) of £3781 per QALY. Cost-effectiveness declines at time horizons shorter than 10 years. Sensitivity analyses demonstrated that average system battery life had the largest impact on potential cost-effectiveness. CONCLUSION: Within the model limitations, these findings support the use of WiSE-CRT in indicated patients from an economic standpoint. However, improving battery technology should be prioritized to maximize cost-effectiveness in times when health services are under significant financial pressures.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/economia , Análise de Custo-Efetividade , Insuficiência Cardíaca/terapia , Resultado do Tratamento
12.
Front Cardiovasc Med ; 10: 1211560, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37608808

RESUMO

Arrhythmia is an extremely common finding in patients receiving cardiac resynchronisation therapy (CRT). Despite this, in the majority of randomised trials testing CRT efficacy, patients with a recent history of arrhythmia were excluded. Most of our knowledge into the management of arrhythmia in CRT is therefore based on arrhythmia trials in the heart failure (HF) population, rather than from trials dedicated to the CRT population. However, unique to CRT patients is the aim to reach as close to 100% biventricular pacing (BVP) as possible, with HF outcomes greatly influenced by relatively small changes in pacing percentage. Thus, in comparison to the average HF patient, there is an even greater incentive for controlling arrhythmia, to achieve minimal interference with the effective delivery of BVP. In this review, we examine both atrial and ventricular arrhythmias, addressing their impact on CRT, and discuss the available evidence regarding optimal arrhythmia management in this patient group. We review pharmacological and procedural-based approaches, and lastly explore novel ways of harnessing device data to guide treatment of arrhythmia in CRT.

13.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37466333

RESUMO

AIMS: Female sex is a recognized risk factor for procedure-related major complications including in-hospital mortality following transvenous lead extraction (TLE). Long-term outcomes following TLE stratified by sex are unclear. The purpose of this study was to evaluate factors influencing long-term survival in patients undergoing TLE according to sex. METHODS AND RESULTS: Clinical data from consecutive patients undergoing TLE in the reference centre between 2000 and 2019 were prospectively collected. The total cohort was divided into groups based on sex. We evaluated the association of demographic, clinical, device-related, and procedure-related factors on long-term mortality. A total of 1151 patients were included, with mean 66-month follow-up and mortality of 34.2% (n = 392). The majority of patients were male (n = 834, 72.4%) and 312 (37.4%) died. Males were more likely to die on follow-up [hazard ratio (HR) = 1.58 (1.23-2.02), P < 0.001]. Males had a higher mean age at explant (66.2 ± 13.9 vs. 61.3 ± 16.3 years, P < 0.001), greater mean co-morbidity burden (2.14 vs. 1.27, P < 0.001), and lower mean left ventricular ejection fraction (LVEF) (43.4 ± 14.0 vs. 50.8 ± 12.7, P = 0.001). For the female cohort, age > 75 years [HR = 3.45 (1.99-5.96), P < 0.001], estimated glomerular filtration rate < 60 [HR = 1.80 (1.03-3.11), P = 0.037], increasing co-morbidities (HR = 1.29 (1.06-1.56), P = 0.011), and LVEF per percentage increase [HR = 0.97 (0.95-0.99), P = 0.005] were all significant factors predicting mortality. The same factors influenced mortality in the male cohort; however, the HRs were lower. CONCLUSION: Female patients undergoing TLE have more favourable long-term outcomes than males with lower long-term mortality. Similar factors influenced mortality in both groups.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Masculino , Feminino , Idoso , Desfibriladores Implantáveis/efeitos adversos , Volume Sistólico , Função Ventricular Esquerda , Fatores de Risco , Comorbidade , Remoção de Dispositivo/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
14.
Heart Rhythm ; 20(11): 1481-1488, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37453603

RESUMO

BACKGROUND: The WiSE-CRT System (EBR systems, Sunnyvale, CA) permits leadless left ventricular pacing. Currently, no intraprocedural guidance is used to target optimal electrode placement while simultaneously guiding acoustic transmitter placement in close proximity to the electrode to ensure adequate power delivery. OBJECTIVE: The purpose of this study was to assess the use of computed tomography (CT) anatomy, dynamic perfusion and mechanics, and predicted activation pattern to identify both the optimal electrode and transmitter locations. METHODS: A novel CT protocol was developed using preprocedural imaging and simulation to identify target segments (TSs) for electrode implantation, with late electrical and mechanical activation, with ≥5 mm wall thickness without perfusion defects. Modeling of the acoustic intensity from different transmitter implantation sites to the TSs was used to identify the optimal transmitter location. During implantation, TSs were overlaid on fluoroscopy to guide optimal electrode location that were evaluated by acute hemodynamic response (AHR) by measuring the maximal rate of left ventricular pressure rise with biventricular pacing. RESULTS: Ten patients underwent the implantation procedure. The transmitter could be implanted within the recommended site on the basis of preprocedural analysis in all patients. CT identified a mean of 4.8 ± 3.5 segments per patient with wall thickness < 5 mm. During electrode implantation, biventricular pacing within TSs resulted in a significant improvement in AHR vs non-TSs (25.5% ± 8.8% vs 12.9% ± 8.6%; P < .001). Pacing in CT-identified scar resulted in either failure to capture or minimal AHR improvement. The electrode was targeted to the TSs in all patients and was implanted in the TSs in 80%. CONCLUSION: Preprocedural imaging and modeling data with intraprocedural guidance can successfully guide WiSE-CRT electrode and transmitter implantation to allow optimal AHR and adequate power delivery.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Dispositivos de Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Terapia de Ressincronização Cardíaca/métodos , Eletrodos , Tomografia Computadorizada por Raios X , Perfusão , Resultado do Tratamento , Ventrículos do Coração/diagnóstico por imagem
15.
Artigo em Inglês | MEDLINE | ID: mdl-37427300

RESUMO

Leadless pacing is a rapidly growing field. Initially designed to provide right ventricular pacing for those who were contraindicated for conventional devices, the technology is growing to explore the potential benefit of avoiding long-term transvenous leads in any patient who requires pacing. In this review, we first examine the safety and performance of leadless pacing devices. We then review the evidence for their use in special populations, such as patients with high risk of device infection, patients on haemodialysis, and patients with vasovagal syncope who represent a younger population who may wish to avoid transvenous pacing. We also summarise the evidence for leadless cardiac resynchronisation therapy and conduction system pacing and discuss the challenges of managing issues, such as system revisions, end of battery life and extractions. Finally, we discuss future directions in the field, such as completely leadless cardiac resynchronisation therapy-defibrillator devices and whether leadless pacing has the potential to become a first-line therapy in the near future.

16.
Heart Rhythm ; 20(12): 1629-1636, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37516414

RESUMO

BACKGROUND: Biventricular endocardial pacing (BiV-endo) and left bundle branch area pacing (LBBAP) are novel methods of delivering cardiac resynchronization therapy. These techniques are associated with improved activation times and acute hemodynamic response compared with conventional biventricular epicardial pacing (BiV-epi); however, the effects on repolarization and arrhythmic risk are unknown. OBJECTIVE: The purpose of this study was to compare the effects of temporary BiV-epi, BiV-endo, and LBBAP on epicardial left ventricular (LV) repolarization using electrocardiographic imaging (ECGi). METHODS: Eleven patients indicated for cardiac resynchronization therapy underwent a temporary pacing protocol with ECGi. BiV-endo was delivered via endocardial stimulation of the LV lateral wall. LBBAP was delivered by pacing the LV septum. Epicardial LV repolarization time (LVRT-95; time taken for 95% of the LV to repolarize), LV RT dispersion, mean LV activation recovery interval (ARI), LV ARI dispersion, and RT gradients were calculated. RESULTS: The protocol was completed in 10 patients. During LBBAP, there were significant reductions in LVRT-95 (94.9 ± 17.4 ms vs 125.0 ± 29.4 ms; P = .03) and LV RT dispersion (29.4 ± 6.3 ms vs 40.8 ± 11.4 ms; P = .015) compared with BiV-epi. In contrast, there were no significant differences between baseline, BiV-epi, or BiV-endo. There was a nonsignificant reduction in mean RT gradients between LBBAP and baseline rhythm (0.74 ± 0.22 ms/mm vs 1.01 ± 0.31 ms/mm; P = .07). There were no significant differences in mean LV ARI or LV ARI dispersion between groups. CONCLUSION: Temporary LBBAP reduces epicardial dispersion of repolarization compared with conventional BiV-epi. Further study is required to determine whether these repolarization changes on ECGi translate into a reduced risk of ventricular arrhythmia in clinical practice.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Septo Interventricular , Humanos , Terapia de Ressincronização Cardíaca/métodos , Sistema de Condução Cardíaco , Arritmias Cardíacas/terapia , Ventrículos do Coração , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia
17.
Front Cardiovasc Med ; 10: 1187754, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37304966

RESUMO

Conduction system pacing (CSP) has emerged as a promising novel delivery method for Cardiac Resynchronisation Therapy (CRT), providing an alternative to conventional biventricular epicardial (BiV) pacing in indicated patients. Despite increasing popularity and widespread uptake, CSP has rarely been specifically examined in patients with atrial fibrillation (AF), a cohort which forms a significant proportion of the heart failure (HF) population. In this review, we first examine the mechanistic evidence for the importance of sinus rhythm (SR) in CSP by allowing adjustment of atrioventricular delays (AVD) to achieve the optimal electrical response, and thus, whether the efficacy of CSP may be significantly attenuated compared to conventional BiV pacing in the presence of AF. We next evaluate the largest clinical body of evidence in this field, related to patients receiving CSP following atrioventricular nodal ablation (AVNA) for AF. Finally, we discuss how future research may be designed to address the vital question of how effective CSP in AF patients is, and the potential hurdles we may face in delivering such studies.

18.
Med Image Anal ; 88: 102861, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37327613

RESUMO

Quantifying uncertainty of predictions has been identified as one way to develop more trustworthy artificial intelligence (AI) models beyond conventional reporting of performance metrics. When considering their role in a clinical decision support setting, AI classification models should ideally avoid confident wrong predictions and maximise the confidence of correct predictions. Models that do this are said to be well calibrated with regard to confidence. However, relatively little attention has been paid to how to improve calibration when training these models, i.e. to make the training strategy uncertainty-aware. In this work we: (i) evaluate three novel uncertainty-aware training strategies with regard to a range of accuracy and calibration performance measures, comparing against two state-of-the-art approaches, (ii) quantify the data (aleatoric) and model (epistemic) uncertainty of all models and (iii) evaluate the impact of using a model calibration measure for model selection in uncertainty-aware training, in contrast to the normal accuracy-based measures. We perform our analysis using two different clinical applications: cardiac resynchronisation therapy (CRT) response prediction and coronary artery disease (CAD) diagnosis from cardiac magnetic resonance (CMR) images. The best-performing model in terms of both classification accuracy and the most common calibration measure, expected calibration error (ECE) was the Confidence Weight method, a novel approach that weights the loss of samples to explicitly penalise confident incorrect predictions. The method reduced the ECE by 17% for CRT response prediction and by 22% for CAD diagnosis when compared to a baseline classifier in which no uncertainty-aware strategy was included. In both applications, as well as reducing the ECE there was a slight increase in accuracy from 69% to 70% and 70% to 72% for CRT response prediction and CAD diagnosis respectively. However, our analysis showed a lack of consistency in terms of optimal models when using different calibration measures. This indicates the need for careful consideration of performance metrics when training and selecting models for complex high risk applications in healthcare.


Assuntos
Doença da Artéria Coronariana , Aprendizado Profundo , Humanos , Calibragem , Inteligência Artificial , Incerteza , Coração , Doença da Artéria Coronariana/diagnóstico por imagem
19.
J Diabetes Metab Disord ; 22(1): 155-174, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37250370

RESUMO

Introduction: Physical exercise deters the risk and reduce the adjusted Odds Ratio related to obesity and cardiometabolic diseases but the amount of physical exercise required for initiating those potential advantageous developments in the human body for normal obese individuals is still debatable and thus made many face the health burden during pandemic, despite of their claiming to be physically active. Objective: The primary aim of this review was to find an ideal duration and form of exercise that could help reduce the risk of cardiometabolic diseases and its complications for subjects with obesity and deranged cardiometabolic risk markers. Method: Electronic database PubMed/MedLine, Scopus and PEDro for available literature on Experimental studies and RCT on exercise prescription and its effect on anthropometric measurements as well as key biomarkers in obese individuals, 451 records were procured, 47 full text articles were identified to assess eligibility criteria out of which 19 were finally included in the review. Results: There exists a strong association between cardiometabolic profile and physical activity, poor diet, sedentary lifestyle and continuous exercises for longer duration can lead to reduction in obesity and subjects with cardiometabolic diseases. Conclusion: Various confounding factors that may affect the outcome of physical activity training have not been considered in a standard format by all the authors in the articles reviewed. There was variation in duration of physical activity and energy expenditure required for inducing the changes in different cardiometabolic biomarkers.

20.
Virulence ; 14(1): 2190647, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-36919498

RESUMO

Lumpy skin disease (LSD) was reported for the first time in India in 2019 and since then, it has become endemic. Since a homologous (LSD-virus based) vaccine was not available in the country, goatpox virus (GPV)-based heterologous vaccine was authorized for mass immunization to induce protection against LSD in cattle. This study describes the evaluation of safety, immunogenicity and efficacy of a new live-attenuated LSD vaccine developed by using an Indian field strain, isolated in 2019 from cattle. The virus was attenuated by continuous passage (P = 50) in Vero cells. The vaccine (50th LSDV passage in Vero cells, named as Lumpi-ProVacInd) did not induce any local or systemic reaction upon its experimental inoculation in calves (n = 10). At day 30 post-vaccination (pv), the vaccinated animals were shown to develop antibody- and cell-mediated immune responses and exhibited complete protection upon virulent LSDV challenge. A minimum Neethling response (0.018% animals; 5 out of 26,940 animals) of the vaccine was observed in the field trials conducted in 26,940 animals. There was no significant reduction in the milk yield in lactating animals (n = 10108), besides there was no abortion or any other reproductive disorder in the pregnant animals (n = 2889). Sero-conversion was observed in 85.18% animals in the field by day 30 pv.


Assuntos
Doença Nodular Cutânea , Vírus da Doença Nodular Cutânea , Vacinas Virais , Animais , Bovinos , Feminino , Chlorocebus aethiops , Doença Nodular Cutânea/prevenção & controle , Doença Nodular Cutânea/epidemiologia , Vírus da Doença Nodular Cutânea/genética , Vacinas Atenuadas/efeitos adversos , Células Vero , Vacinas Virais/administração & dosagem