Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Polymers (Basel) ; 13(16)2021 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-34451224

RESUMO

Orthopaedic implants and temporary osteosynthesis devices are commonly based on Titanium (Ti). For short-term devices, cell-material contact should be restricted for easy removal after bone healing. This could be achieved with anti-adhesive plasma-fluorocarbon-polymer (PFP) films created by low-temperature plasma processes. Two different PFP thin film deposition techniques, microwave (MW) and radiofrequency (RF) discharge plasma, were applied to receive smooth, hydrophobic surfaces with octafluoropropane (C3F8) or hexafluorohexane (C6F6) as precursors. This study aimed at examining the immunological local tissue reactions after simultaneous intramuscular implantation of four different Ti samples, designated as MW-C3F8, MW-C6F6, RF-C3F8 and Ti-controls, in rats. A differentiated morphometric evaluation of the inflammatory reaction was conducted by immunohistochemical staining of CD68+ macrophages, CD163+ macrophages, MHC class II-positive cells, T lymphocytes, CD25+ regulatory T lymphocytes, NK cells and nestin-positive cells in cryosections of surrounding peri-implant tissue. Tissue samples were obtained on days 7, 14 and 56 for investigating the acute and chronical inflammation (n = 8 rats/group). Implants with a radiofrequency discharge plasma (RF-C3F8) coating exhibited a favorable short- and long-term immune/inflammatory response comparable to Ti-controls. This was also demonstrated by the significant decrease in pro-inflammatory CD68+ macrophages, possibly downregulated by significantly increasing regulatory T lymphocytes.

2.
Materials (Basel) ; 9(7)2016 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-28773715

RESUMO

Plasma polymerized a-C:H thin films have been deposited on Si (100) and aluminum coated glass substrates by a dielectric barrier discharge (DBD) operated at medium pressure using C2Hm/Ar (m = 2, 4, 6) gas mixtures. The deposited films were characterized by Fourier transform infrared reflection absorption spectroscopy (FT-IRRAS), Raman spectroscopy, and ellipsometry. FT-IRRAS revealed the presence of sp³ and sp² C-H stretching and C-H bending vibrations of bonds in the films. The presence of D and G bands was confirmed by Raman spectroscopy. Thin films obtained from C2H4/Ar and C2H6/Ar gas mixtures have ID/IG ratios of 0.45 and 0.3, respectively. The refractive indices were 2.8 and 3.1 for C2H4/Ar and C2H6/Ar films, respectively, at a photon energy of 2 eV.

3.
Biomed Res Int ; 2015: 103137, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26064874

RESUMO

A common method to derive both qualitative and quantitative data to evaluate osseointegration of implants is histomorphometry. The present study describes a new image reconstruction algorithm comparing the results of bone-to-implant contact (BIC) evaluated by means of µCT with histomorphometry data. Custom-made conical titanium alloyed (Ti6Al4V) implants were inserted in the distal tibial bone of female Sprague-Dawley rats. Different surface configurations were examined: Ti6Al4V implants with plasma-polymerized allylamine (PPAAm) coating and plasma-polymerized ethylenediamine (PPEDA) coating as well as implants without surface coating. After six weeks postoperatively, tibiae were explanted and BIC was determined by µCT (3D) and afterwards by histomorphometry (2D). In comparison to uncoated Ti6Al4V implants demonstrating low BIC of 32.4% (histomorphometry) and 51.3% (µCT), PPAAm and PPEDA coated implants showed a nonsignificant increase in BIC (histomorphometry: 45.7% and 53.5% and µCT: 51.8% and 62.0%, resp.). Mean BIC calculated by µCT was higher for all surface configurations compared to BIC detected by histomorphometry. Overall, a high correlation coefficient of 0.70 (p < 0.002) was found between 3D and 2D quantification of BIC. The µCT analysis seems to be suitable as a nondestructive and accurate 3D imaging method for the evaluation of the bone-implant interface.


Assuntos
Materiais Revestidos Biocompatíveis , Osseointegração , Próteses e Implantes , Titânio , Algoritmos , Ligas , Animais , Etilenodiaminas , Feminino , Imageamento Tridimensional , Teste de Materiais , Poliaminas , Ratos , Ratos Sprague-Dawley , Tíbia/diagnóstico por imagem , Tíbia/patologia , Tíbia/cirurgia , Microtomografia por Raio-X
4.
Int J Mol Sci ; 15(2): 2454-64, 2014 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-24521883

RESUMO

By means of plasma polymerization, positively charged, nanometre-thin coatings can be applied to implant surfaces. The aim of the present study was to quantify the adhesion of human bone cells in vitro and to evaluate the bone ongrowth in vivo, on titanium surfaces modified by plasma polymer coatings. Different implant surface configurations were examined: titanium alloy (Ti6Al4V) coated with plasma-polymerized allylamine (PPAAm) and plasma-polymerized ethylenediamine (PPEDA) versus uncoated. Shear stress on human osteoblast-like MG-63 cells was investigated in vitro using a spinning disc device. Furthermore, bone-to-implant contact (BIC) was evaluated in vivo. Custom-made conical titanium implants were inserted at the medial tibia of female Sprague-Dawley rats. After a follow-up of six weeks, the BIC was determined by means of histomorphometry. The quantification of cell adhesion showed a significantly higher shear stress for MG-63 cells on PPAAm and PPEDA compared to uncoated Ti6Al4V. Uncoated titanium alloyed implants showed the lowest BIC (40.4%). Implants with PPAAm coating revealed a clear but not significant increase of the BIC (58.5%) and implants with PPEDA a significantly increased BIC (63.7%). In conclusion, plasma polymer coatings demonstrate enhanced cell adhesion and bone ongrowth compared to uncoated titanium surfaces.


Assuntos
Osseointegração , Polimerização , Próteses e Implantes , Titânio , Ligas , Animais , Adesão Celular , Linhagem Celular , Materiais Revestidos Biocompatíveis , Feminino , Humanos , Osteoblastos/metabolismo , Ratos
5.
J Mater Sci Mater Med ; 24(3): 761-71, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23314622

RESUMO

Copper (Cu) could serve as antibacterial coating for Ti6Al4V implants. An additional cell-adhesive layer might compensate Cu cytotoxicity. This study aimed at in vitro and in vivo evaluation of low-temperature plasma treatment of Ti6Al4V plates with Ti/Cu magnetron sputtering (Ti6Al4V-Ti/Cu), plasma-polymerized ethylenediamine (Ti6Al4V-PPEDA), or both (Ti6Al4V-Ti/Cu-PPEDA). Ti6Al4V-Ti/Cu and Ti6Al4V-Ti/Cu-PPEDA had comparable in vitro Cu release and antibacterial effectiveness. Following intramuscular implantation of Ti6Al4V-Ti/Cu, Ti6Al4V-PPEDA, Ti6Al4V-Ti/Cu-PPEDA and Ti6Al4V controls for 7, 14 and 56 days with 8 rats/day, peri-implant tissue was immunohistochemically examined for different inflammatory cells. Ti6Al4V-PPEDA had more mast cells and NK cells than Ti6Al4V, and more tissue macrophages, T lymphocytes, mast cells and NK cells than Ti6Al4V-Ti/Cu-PPEDA. Ti6Al4V-Ti/Cu had more mast cells than Ti6Al4V and Ti6Al4V-Ti/Cu-PPEDA. Results indicate that PPEDA-mediated cell adhesion counteracted Cu cytotoxicity. Ti6Al4V-Ti/Cu-PPEDA differed from Ti6Al4V only for mast cells on day 56. Altogether, implants with both plasma treatments had antibacterial properties and did not increase inflammatory reactions.


Assuntos
Cobre/química , Etilenodiaminas/química , Inflamação/etiologia , Gases em Plasma , Titânio/efeitos adversos , Ligas , Animais , Biofilmes , Imuno-Histoquímica , Inflamação/imunologia , Linfócitos/imunologia , Masculino , Testes de Sensibilidade Microbiana , Ratos , Ratos Endogâmicos Lew , Staphylococcus aureus , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...