Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Vet Res ; 14(1): 123, 2018 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-29615113

RESUMO

BACKGROUND: Phacoemulsification and intraocular lens (IOL) implantation during cataract surgery in horses occur with increasing frequency. To reduce the postoperative refractive error it is necessary to determine the proper IOL power. In the present study retinoscopy, keratometry and ultrasonographic biometry were performed on 98 healthy equine eyes from 49 horses. The refractive state, corneal curvature (keratometry) and the axial location of all optical interfaces (biometry) were measured. The influences of breed, height at the withers, gender and age on values obtained and the comparison between the left and right eye were evaluated statistically. Corresponding IOL power were calculated by use of Binkhorst and Retzlaff theoretical formulas. RESULTS: Mean ± SD refractive state of the horses was + 0.32 ± 0.66 D. Averaged corneal curvature for Haflinger, Friesian, Pony, Shetland pony and Warmblood were 21.30 ± 0.56 D, 20.02 ± 0.60 D, 22.61 ± 1.76 D, 23.77 ± 0.94 D and 20.76 ± 0.88 D, respectively. The estimated postoperative anterior chamber depth (C) was calculated by the formula C = anterior chamber depth (ACD)/0.73. This formula was determined by a different research group. C and axial length of the globe averaged for Haflinger 9.30 ± 0.54 mm and 39.43 ± 1.26 mm, for Friesian 10.12 ± 0.33 mm and 42.23 ± 1.00 mm, for Pony 8.68 ± 0.78 mm and 38.85 ± 3.13 mm, for Shetland pony 8.71 ± 0.81 mm and 37.21 ± 1.50 mm and for Warmblood 9.39 ± 0.51 mm and 40.65 ± 1.30 mm. IOL power was calculated with the Binkhorst and Retzlaff theoretical formulas. Calculated IOL power for the several breeds ranged from 18.03 D to 19.55 D. The mean value across all horses was 18.73 D determined with Binkhorst formula and 18.54 D determined with Retzlaff formula. CONCLUSIONS: Mean result of this study is: an 18.5 D IOL seemed to be the most appropriate to achieve emmetropia after IOL implantation in horses. Cataract surgery without IOL implantation results in hyperopic and visual compromised horses. Retinoscopy, keratometry and ultrasonographic biometry should be performed on every affected horse and postoperative visual outcome should be determined.


Assuntos
Olho/anatomia & histologia , Cavalos/fisiologia , Lentes Intraoculares/veterinária , Animais , Córnea/anatomia & histologia , Córnea/fisiologia , Olho/diagnóstico por imagem , Feminino , Cavalos/anatomia & histologia , Masculino , Fenômenos Fisiológicos Oculares , Refração Ocular/fisiologia , Retinoscopia/veterinária , Ultrassonografia/veterinária
2.
BMC Vet Res ; 10: 250, 2014 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-25312851

RESUMO

BACKGROUND: Sonographic ophthalmic examinations have become increasingly important in veterinary medicine. If the velocity of ultrasound in ocular tissues is known, the A-mode ultrasound method may be used to determine the axial intraocular distances, such as anterior chamber depth, lens thickness, axial length of the vitreous and axial globe length, which are required for intraocular lens (IOL) power calculations. To the authors' knowledge, the velocity of ultrasound in the ocular tissues of the horse was not previously determined. In the present study, 33 lenses, 29 samples of aqueous and 31 of vitreous from 35 healthy equine eyes have been examined. The corresponding ultrasound velocities are reported in dependence of age, temperature, gender and elapsed time after enucleation. RESULTS: The velocity of ultrasound at 36°C in equine aqueous, lens and vitreous are 1529 ±10 m/s, 1654± 29 m/s and 1527 ±16 m/s respectively, and the corresponding conversion factors are 0.998± 0.007, 1.008 ±0.018 and 0.997 ±0.010. A linear increase of the speed of ultrasound with increasing temperature has been determined for aqueous and vitreous. No temperature dependence was found for the speed of ultrasound in the lens. The ultrasound velocity did not significantly differ (95%) on the basis of gender, age or time after enucleation during the first 72 hours after death. CONCLUSIONS: Compared to human eyes, the ultrasound velocity in equine lental tissue deviates by one percent. Therefore, axial length measurements obtained with ultrasound velocities for the human eye must be corrected using conversion factors. For the aqueous and vitreous, deviations are below one percent and can be neglected in clinical settings.


Assuntos
Humor Aquoso/diagnóstico por imagem , Cavalos/anatomia & histologia , Cristalino/diagnóstico por imagem , Corpo Vítreo/diagnóstico por imagem , Animais , Feminino , Masculino , Ultrassonografia
3.
Eur J Obstet Gynecol Reprod Biol ; 126(2): 217-25, 2006 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-16387409

RESUMO

BACKGROUND: Pre-implantation genetic diagnosis (PGD) is a modern technique in reproductive medicine which can be used to diagnose genetic disorders of an embryo. PGD is currently not legal in Germany, still there are debates being held regarding the issue of legalization. Both the internationally "accepted" indications and new or alternative approaches can lead to complex ethical dilemmas. The attitudes towards PGD have rarely been assessed in the general population. METHODS: In our study, 2110 persons aged 18-50 years were interviewed about their attitudes towards PGD and related topics. We assumed that religion, world views and the evaluation of PGD would influence the attitude a person has towards this procedure. RESULTS AND CONCLUSIONS: In our survey, the majority of respondents would agree to a restricted legalization of PGD in Germany. Our results also confirmed some of our assumptions but religion did not have the expected influence. The evaluation of costs and benefits of PGD and the feelings associated with this technique explained more of the final attitude whether PGD should remain prohibited in Germany or not. The agreement to a restricted legalization may be connected to an overall rejection of prohibitions made by the state concerning the individual reproductive autonomy.


Assuntos
Atitude Frente a Saúde , Diagnóstico Pré-Implantação/ética , Diagnóstico Pré-Implantação/psicologia , Opinião Pública , Adolescente , Adulto , Feminino , Identidade de Gênero , Alemanha , Humanos , Pessoa de Meia-Idade , Gravidez , Religião , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...