Ann Vasc Surg ; 64: 270-275, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31629847

RESUMO

BACKGROUND: Pseudoaneurysm formation is common in standard thin-walled polytetrafluoroethylene (sPTFE) grafts, occurring in up to 10% of grafts, and is reported as the most common cause of graft loss for grafts more than 2 years old. The Gore® Acuseal™ graft is an early cannulation graft, needled before incorporation, and thus may be especially prone to pseudoaneurysm formation. In addition, as this is a relatively new product, there are limited data on long-term outcomes such as pseudoaneurysm. We report one center's experience of the incidence and etiological factors associated with pseudoaneurysm formation over 5 years and 265 grafts. METHODS: A total of 265 Acuseal grafts were placed in the last 5 years. All patients had prospective data entered into an electronic searchable patient record. Surveillance was performed with 3 monthly imaging (digital subtraction angiography or ultrasound), clinical examination, and hemodynamic performance. Data examined included the incidence, causative factors, and outcomes of pseudoaneurysm. RESULTS: Eleven grafts (4.15%) developed a pseudoaneurysm, with 2 patients developing significant hemorrhage. The median time to development of a pseudoaneurysm was 25 months interquartile range (IQR, 20-28 months). Several common etiological factors were identified. All but one patient had overuse of needling sites (n = 10; 90.9%). Other factors associated with pseudoaneurysm formation were inadequate surveillance (n = 9; 81.8%), venous outflow stenosis (n = 9; 81.8%), and anticoagulation/dual antiplatelet therapy (n = 7; 63.6%). Management included observation and needle rotation (n = 5; 45.5%), stent grafting (n = 3; 27.3%), or excision (n = 1; 9.1%) of the pseudoaneurysm. Surgical or endovascular augmentation of the venous outflow was required in 9 patients (81.8%). Graft ligation and explantation were required in 5 patients (45.5%) with graft preservation achieved in 6/11 patients (54.5%). CONCLUSIONS: Pseudoaneurysm formation occurs less frequently in Acuseal grafts compared with historical data for standard PTFE grafts. Pseudoaneurysm formation did not occur in any graft within the first 13 months after implantation, suggesting early cannulation before incorporation is not by itself a risk factor for pseudoaneurysm development. Poor needling, venous stenosis, inadequate surveillance, and anticoagulation/dual antiplatelet therapy are remediable factors, and graft preservation is possible. Acuseal is a robust graft with lower rates of pseudoaneurysm formation on long-term follow-up than standard PTFE grafts.


Assuntos
Falso Aneurisma/epidemiologia , Derivação Arteriovenosa Cirúrgica/instrumentação , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Cateterismo , Politetrafluoretileno , Diálise Renal , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/cirurgia , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Cateterismo/efeitos adversos , Bases de Dados Factuais , Remoção de Dispositivo , Feminino , Humanos , Incidência , Masculino , Desenho de Prótese , Reoperação , Estudos Retrospectivos , Fatores de Risco , Escócia/epidemiologia , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...