Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 14(1): 2201, 2024 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-38273032

RESUMO

Due to the difficulties in retrieving both the time-dependent shapes of the vessels and the generation of numerical meshes for such cases, most of the simulations of blood flow in the cardiac arteries use static geometry. The article describes a methodology for generating a sequence of time-dependent 3D shapes based on images of different resolutions and qualities acquired from ECG-gated coronary artery CT angiography. The precision of the shape restoration method has been validated using an independent technique. The original proposed approach also generates for each of the retrieved vessel shapes a numerical mesh of the same topology (connectivity matrix), greatly simplifying the CFD blood flow simulations. This feature is of significant importance in practical CFD simulations, as it gives the possibility of using the mesh-morphing utility, minimizing the computation time and the need of interpolation between boundary meshes at subsequent time instants. The developed technique can be applied to generate numerical meshes in arteries and other organs whose shapes change over time. It is applicable to medical images produced by other than angio-CT modalities.


Assuntos
Vasos Coronários , Hemodinâmica , Humanos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Angiografia Coronária/métodos , Próteses e Implantes , Tomografia Computadorizada por Raios X
2.
Comput Methods Programs Biomed ; 226: 107117, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36122496

RESUMO

BACKGROUND AND OBJECTIVE: In recent years, progress in microfabrication technologies has attracted the attention of researchers across disciplines. Microfluidic devices have the potential to be developed into powerful tools that can elucidate the biophysical behavior of blood flow in microvessels. Such devices can also be used to separate the suspended physiological fluid from whole in vitro blood, which includes cells. Therefore, it is essential to acquire a detailed description of the complex interaction between erythrocytes (red blood cells; RBCs) and plasma. RBCs tend to undergo axial migration caused by occurrence of the Fåhræus-Lindqvist effect. These dynamics result in a cell-free layer (CFL), or a low volume fraction of cells, near the vessel wall. The aim of the paper is to develop a numerical model capable of reproducing the behavior of multiphase flow in a microchannel obtained under laboratory conditions and to compare two multiphase modelling techniques Euler-Euler and Euler-Lagrange. METHODS: In this work, we employed a numerical Computational Fluid Dynamics (CFD) model of the blood flow within microchannels with two hyperbolic contraction shapes. The simulation was used to reproduce the blood flow behavior in a microchannel under laboratory conditions, where the CFL formation is visible downstream of the hyperbolic contraction. The multiphase numerical model was developed using Euler-Euler and hybrid Euler-Lagrange approaches. The hybrid CFD simulation of the RBC transport model was performed using a Discrete Phase Model. Blood was assumed to be a nonhomogeneous mixture of two components: dextran, whose properties are consistent with plasma, and RBCs, at a hematocrit of 5% (percent by volume of RBCs). RESULTS: The results show a 5 µm thick CFL in a microchannel with a broader contraction and a 35 µm thick CFL in a microchannel with a narrower contraction. The RBC volume fraction in the CFL is less than 2%, compared to 7-8% in the core flow. The results are consistent for both multiphase simulation techniques used. The simulation results were then validated against the experimentally-measured CFL in each of the studied microchannel geometries. CONCLUSIONS: Reasonable agreement between experiments and simulations was achieved. A validated model such as the one tested in this study can expedite the microchannel design process by minimizing the need to prefabricate prototypes and test them under laboratory conditions.


Assuntos
Eritrócitos , Hidrodinâmica , Hemodinâmica/fisiologia , Simulação por Computador , Microvasos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...