Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nanoscale Res Lett ; 11(1): 106, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26911570

RESUMO

Development of a conductometric biosensor for the urea detection has been reported. It was created using a non-typical method of the recombinant urease immobilization via adsorption on nanoporous particles of silicalite. It should be noted that this biosensor has a number of advantages, such as simple and fast performance, the absence of toxic compounds during biosensor preparation, and high reproducibility (RSD = 5.1 %). The linear range of urea determination by using the biosensor was 0.05-15 mM, and a lower limit of urea detection was 20 µM. The bioselective element was found to be stable for 19 days. The characteristics of recombinant urease-based biomembranes, such as dependence of responses on the protein and ion concentrations, were investigated. It is shown that the developed biosensor can be successfully used for the urea analysis during renal dialysis.

2.
Talanta ; 115: 200-7, 2013 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-24054580

RESUMO

The aim of this work was to develop an array of biosensors for simultaneous determination of four carbohydrates in solution. Several enzyme systems selective to lactose, maltose, sucrose and glucose were immobilised on the surface of four conductometric transducers and served as bio-recognition elements of the biosensor array. Direct enzyme analysis carried out by the developed biosensors was highly sensitive to the corresponding substrates. The analysis lasted 2 min. The dynamic range of substrate determination extended from 0.001 mM to 1.0-3.0mM, and strongly depended on the enzyme system used. An effect of the solution pH, ionic strength and buffer capacity on the biosensors responses was investigated; the conditions of simultaneous operation of all biosensors were optimised. The data on cross-impact of the substrates of all biosensors were obtained; the biosensor selectivity towards possible interfering carbohydrates was tested. The developed biosensor array showed good signal reproducibility and storage stability. The biosensor array is suited for simultaneous, quick, simple, and selective determination of maltose, lactose, sucrose and glucose.


Assuntos
Técnicas Biossensoriais/instrumentação , Condutometria/métodos , Glucose/análise , Lactose/análise , Maltose/análise , Sacarose/análise , Calibragem , Condutometria/instrumentação , Enzimas Imobilizadas/química , Concentração de Íons de Hidrogênio , Concentração Osmolar , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Soluções , Transdutores , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...