J Clin Monit Comput ; 29(1): 65-76, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24619657

RESUMO

The rationale for intrathoracic impedance (Z) detection of worsening heart failure (HF) presupposes that changes in Z reflect changes in pulmonary congestion, but is confounded by poor specificity in clinical trials. We therefore tested the hypothesis that Z is primarily affected by tissue/water content in proximity to electrodes rather than by lung water distribution between electrodes through the use of a new computational model for deriving the near-field impedance contributions from the various electrodes. Six sheep were implanted with a left atrial pressure (LAP) monitor and a cardiac resynchronization therapy device which measured Z from six vectors comprising of five electrodes. The vector-based Z was modelled as the summation of the near-field impedances of the two electrodes forming the vector. During volume expansion an acute increase in LAP resulted in simultaneous reductions in the near-field impedances of the intra-cardiac electrodes, while the subcutaneous electrode showed several hours of lag (all p<0.001). In contrast, during the simulated formation of device-pocket edema (induced by fluid injection) the near-field impedance of the subcutaneous electrode had an instantaneous response, while the intra-cardiac electrodes had a minimal inconsistent response. This study suggests that the primary contribution to the vector based Z is from the tissue/water in proximity to the individual electrodes. This novel finding may help explain the limited utility of Z for detecting worsening HF.


Assuntos
Cardiografia de Impedância/métodos , Impedância Elétrica , Insuficiência Cardíaca/diagnóstico , Pulmão/patologia , Algoritmos , Anestesia Geral , Animais , Determinação da Pressão Arterial/métodos , Simulação por Computador , Edema/patologia , Eletrodos , Átrios do Coração/patologia , Insuficiência Cardíaca/patologia , Monitorização Fisiológica/métodos , Edema Pulmonar/diagnóstico , Ovinos , Fatores de Tempo , Água/química
2.
Pacing Clin Electrophysiol ; 37(7): 810-9, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24502608

RESUMO

BACKGROUND: We hypothesized that left atrial pressure (LAP) obtained by a permanent implantable sensor is sensitive to changes in cardiac resynchronization therapy (CRT) settings and could guide CRT optimization to improve the response rate. We investigated the effect of CRT optimization on LAP and its waveform parameters in ambulant heart failure (HF) patients. METHODS: CRT optimization was performed in eight ambulant HF patients, using echocardiography as reference. LAP waveform was acquired at each of eight atrioventricular (AV) intervals and five inter-ventricular (VV) intervals. Selected waveform parameters were also evaluated for their sensitivity to CRT changes and agreement with echocardiography-guided optimal settings. RESULTS: Optimal AV and VV intervals varied considerably between patients. All patients exhibited significant changes in waveform morphology with AV optimization. Optimal AV delay determined from echocardiography ranged between 140 ms and 225 ms. Mean LAP tended to be lower at optimal setting 14 ± 3 mmHg compared to shorter (<100 ms) or longer (>160 ms) AV settings (P = 0.16). There were clear trends to smaller peak a-wave (P = 0.11) and gentler positive a-slope (P = 0.15) and positive v-slope (P = 0.09) with longer AV delays. Mean LAP and negative v-wave slope correlated well with echo-guided optimal setting, r = 0.91 (P = 0.001) and 0.79 (P = 0.03), respectively. No significant effects on LAP or waveform were seen during VV optimization. CONCLUSIONS: LAP and its waveform changes considerably with AV optimization. There is good agreement between echo-guided optimal setting and LAP. LAP could provide an objective guide to CRT optimization. (Clinical Trial Registry information: URL: http://www.clinicaltrials.gov. Unique Identifier: NCT00632372).


Assuntos
Pressão Atrial , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Adulto , Idoso , Estudos de Viabilidade , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos
3.
ASAIO J ; 59(5): 486-92, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23851452

RESUMO

A left atrial pressure (LAP) monitoring system was developed for guiding the management of patients with heart failure. The LAP sensor is implanted into the left atrium via transseptal catheterization and affixed to the interatrial septum by nitinol anchors. The long-term safety of permanent implantation of the LAP sensor in patients was evaluated based on the comparative pathology in animals. Tissue specimens of the LAP sensor from 7 patients, 49 canines, and 14 ovine were examined for thrombosis and tissue overgrowth. Implant duration ranged from 22 to 1,686 days. Gross examination showed minimal-to-moderate tissue overgrowth with no evidence of migration, erosion, or perforation. There was no excessive host-to-device reaction or active thrombogenesis in any of the subjects that followed the antithrombotic therapy protocol. Micro-computed tomography scanning confirmed the structural integrity of the device. Low vacuum scanning electron microscopy and histology showed neoendocardial tissue overgrowth with no inflammation or fibrin. The pathology of both animal models was found to closely approximate the pathology in humans and favorably supports the long-term safety of the device.


Assuntos
Pressão Atrial , Átrios do Coração/patologia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Transdutores de Pressão , Animais , Artefatos , Cães , Falha de Equipamento , Insuficiência Cardíaca/terapia , Humanos , Microscopia Eletrônica de Varredura , Modelos Animais , Segurança do Paciente , Pressão , Ovinos , Trombose/fisiopatologia , Fatores de Tempo , Microtomografia por Raio-X
5.
JACC Cardiovasc Imaging ; 4(9): 927-34, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21920328

RESUMO

OBJECTIVES: This study sought to determine the accuracy of Doppler echocardiography and tissue Doppler imaging (TDI) measurements in detecting elevated left atrial pressure (LAP) in ambulant subjects with chronic heart failure using directly measured LAP as the reference. BACKGROUND: Echocardiographic indexes including the ratio of transmitral to annular early diastolic velocities (E/e') may identify raised invasively measured left ventricular filling pressures when tested in cross-sectional studies in some populations. The accuracy of these indexes when measured sequentially remains untested. We determined the accuracy of Doppler echocardiography and TDI measurements in detecting elevated directly measured LAP in ambulant subjects with stable chronic heart failure. METHODS: Fifteen patients with New York Heart Association functional class II to III heart failure and a permanently implanted direct LAP monitoring device underwent serial echocardiography. Simultaneous resting mean LAP, Doppler mitral inflow, mitral annular TDI, and pulmonary venous inflow velocities were obtained on each occasion. Receiver-operator characteristic curve analysis was used to compare the accuracy of the Doppler variables to detect an elevated device LAP ≥15 and ≥20 mm Hg. RESULTS: The patients (13 men, mean age: 71 years, mean left ventricular ejection fraction: 32 ± 12%) underwent 60 simultaneous echocardiographic studies and LAP measurements with a median of 4 (1 to 7) studies per patient. Mean LAP was 16.9 (range 5 to 39 mm Hg) at echocardiography (n = 60). E/e' had the greatest accuracy for detection of LAP ≥15 mm Hg with an area beneath the receiver-operator characteristic curve >0.9. In comparison, area under the curve for mitral E velocity and mitral E/A were 0.77 and 0.76, respectively (p < 0.008 vs. E/e' medial and average). CONCLUSIONS: Single and serial measurements of mitral inflow and mitral annular TDI velocities (E/e') can reliably detect raised directly measured LAP in ambulant subjects with compensated chronic heart failure. (Hemodynamically Guided Home Self-Therapy in Severe Heart Failure Patients [HOMEOSTASIS]; NCT00547729).


Assuntos
Função do Átrio Esquerdo , Ecocardiografia Doppler , Insuficiência Cardíaca/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Monitorização Ambulatorial , Idoso , Idoso de 80 Anos ou mais , Doença Crônica , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Monitorização Ambulatorial/instrumentação , Valor Preditivo dos Testes , Pressão , Curva ROC , Volume Sistólico , Fatores de Tempo , Função Ventricular Esquerda
6.
Europace ; 13(9): 1299-303, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21490038

RESUMO

AIMS: This study examined the prior history of all patients presenting to the regional ambulance service with community cardiac arrest to determine what proportion of these patients had prior indications for implanted cardioverter-defibrillator (ICD) therapy. METHODS AND RESULTS: We reviewed the medical history of all adult patients presenting to our regional ambulance service with cardiac arrest between 1 June 2007 and 31 May 2008 (n= 144). Patients were classified as either not having an ICD indication, having a possible ICD indication, or having an ICD indication by two electrophysiologists. Eighty-seven patients (60%) had no pre-existing indication for an ICD. Twenty-two patients (15%) had a possible indication for an ICD but required further investigation to confirm this. This group consisted of 6 patients (4%) with previously documented left ventricular ejection fraction <35%, but without a measurement in the last 12 months, 14 patients (10%) with heart failure (n= 10) or syncope (n= 4) without appropriate investigations, and 2 patients with an ICD indication but with co-morbidities that required further investigation. Thirty-five patients (24%) had a documented indication for an ICD. In 11 (8%) there was no evidence of a contraindication, in 3 (2%) alternative therapy was judged more appropriate, and in 21 (15%) contraindications to ICD implantation were also present. Addition of the 11 patients with an ICD indication and the 6 patients with a documented indication requiring updated measurement, 17 patients (12%) had a prior documented ICD indication but had not been referred for this therapy. CONCLUSIONS: Our observation that 12% of sudden cardiac arrest patients had prior indications for an ICD demonstrates that there is an unmet need for ICDs in New Zealand.


Assuntos
Desfibriladores Implantáveis/estatística & dados numéricos , Necessidades e Demandas de Serviços de Saúde/estatística & dados numéricos , Idoso , Comorbidade , Contraindicações , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Feminino , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Nova Zelândia , Estudos Retrospectivos , Volume Sistólico/fisiologia , Síncope/epidemiologia , Síncope/terapia , Resultado do Tratamento
7.
J Cardiovasc Transl Res ; 4(1): 3-13, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20945124

RESUMO

We report the stability, accuracy, and development history of a new left atrial pressure (LAP) sensing system in ambulatory heart failure (HF) patients. A total of 84 patients with advanced HF underwent percutaneous transseptal implantation of the pressure sensor. Quarterly noninvasive calibration by modified Valsalva maneuver was achieved in all patients, and 96.5% of calibration sessions were successful with a reproducibility of 1.2 mmHg. Absolute sensor drift was maximal after 3 months at 4.7 mmHg (95% CI, 3.2-6.2 mmHg) and remained stable through 48 months. LAP was highly correlated with simultaneous pulmonary wedge pressure at 3 and 12 months (r = 0.98, average difference of 0.8 ± 4.0 mmHg). Freedom from device failure was 95% (n = 37) at 2 years and 88% (n = 12) at 4 years. Causes of failure were identified and mitigated with 100% freedom from device failure and less severe anomalies in the last 41 consecutive patients (p = 0.005). Accurate and reliable LAP measurement using a chronic implanted monitoring system is safe and feasible in patients with advanced heart failure.


Assuntos
Função do Átrio Esquerdo , Eletrodos Implantados , Insuficiência Cardíaca/diagnóstico , Testes de Função Cardíaca/instrumentação , Monitorização Ambulatorial/instrumentação , Transdutores de Pressão , Austrália , Calibragem , Eletrodos Implantados/normas , Desenho de Equipamento , Falha de Equipamento , Insuficiência Cardíaca/fisiopatologia , Testes de Função Cardíaca/normas , Hemodinâmica , Humanos , Estimativa de Kaplan-Meier , Monitorização Ambulatorial/normas , Nova Zelândia , Valor Preditivo dos Testes , Pressão , Estudos Prospectivos , Pressão Propulsora Pulmonar , Sistema de Registros , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Processamento de Sinais Assistido por Computador , Fatores de Tempo , Transdutores de Pressão/normas , Estados Unidos , Manobra de Valsalva
8.
Clin Sci (Lond) ; 120(5): 207-17, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20846122

RESUMO

Monitoring of HF (heart failure) with intracardiac pressure, intrathoracic impedance and/or natriuretic peptide levels has been advocated. We aimed to investigate possible differences in the response patterns of each of these monitoring modalities during HF decompensation that may have an impact on the potential for early therapeutic intervention. Six sheep were implanted with a LAP (left atrial pressure) sensor and a CRT-D (cardiac resynchronization therapy defibrillator) capable of monitoring impedance along six lead configuration vectors. An estimate of ALAP (LAP from admittance) was determined by linear regression. HF was induced by rapid ventricular pacing at 180 and 220 bpm (beats/min) for a week each, followed by a third week with daily pacing suspensions for increasing durations (1-5 h). Incremental pacing induced progressively severe HF reflected in increases in LAP (5.9 ± 0.4 to 24.5 ± 1.6 mmHg) and plasma atrial (20 ± 3 to 197 ± 36 pmol/l) and B-type natriuretic peptide (3.7 ± 0.7 to 32.7 ± 5.4 pmol/l) (all P<0.001) levels. All impedance vectors decreased in proportion to HF severity (all P<0.001), with the LVring (left ventricular)-case vector correlating best with LAP (r2=0.63, P<0.001). Natriuretic peptides closely paralleled rapid acute changes in LAP during alterations in pacing (P<0.001), whereas impedance changes were delayed relative to LAP. ALAP exhibited good agreement with LAP. In summary, impedance measured with an LV lead correlates significantly with changes in LAP, but exhibits a delayed response to acute alterations. Natriuretic peptides respond rapidly to acute LAP changes. Direct LAP, impedance and natriuretic peptide measurements all show promise as early indicators of worsening HF. ALAP provides an estimate of LAP that may be clinically useful.


Assuntos
Função do Átrio Esquerdo/fisiologia , Insuficiência Cardíaca/diagnóstico , Peptídeos Natriuréticos/sangue , Animais , Biomarcadores/sangue , Estimulação Cardíaca Artificial , Cardiografia de Impedância , Modelos Animais de Doenças , Estudos de Viabilidade , Átrios do Coração/fisiopatologia , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Carneiro Doméstico
9.
N Engl J Med ; 363(1): 36-44, 2010 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-20463331

RESUMO

BACKGROUND: Implantable cardioverter-defibrillators (ICDs) prevent sudden death from cardiac causes in selected patients but require the use of transvenous lead systems. To eliminate the need for venous access, we designed and tested an entirely subcutaneous ICD system. METHODS: First, we conducted two short-term clinical trials to identify a suitable device configuration and assess energy requirements. We evaluated four subcutaneous ICD configurations in 78 patients who were candidates for ICD implantation and subsequently tested the best configuration in 49 additional patients to determine the subcutaneous defibrillation threshold in comparison with that of the standard transvenous ICD. Then we evaluated the long-term use of subcutaneous ICDs in a pilot study, involving 6 patients, which was followed by a trial involving 55 patients. RESULTS: The best device configuration consisted of a parasternal electrode and a left lateral thoracic pulse generator. This configuration was as effective as a transvenous ICD for terminating induced ventricular fibrillation, albeit with a significantly higher mean (+/-SD) energy requirement (36.6+/-19.8 J vs. 11.1+/-8.5 J). Among patients who received a permanent subcutaneous ICD, ventricular fibrillation was successfully detected in 100% of 137 induced episodes. Induced ventricular fibrillation was converted twice in 58 of 59 patients (98%) with the delivery of 65-J shocks in two consecutive tests. Clinically significant adverse events included two pocket infections and four lead revisions. After a mean of 10+/-1 months, the device had successfully detected and treated all 12 episodes of spontaneous, sustained ventricular tachyarrhythmia. CONCLUSIONS: In small, nonrandomized studies, an entirely subcutaneous ICD consistently detected and converted ventricular fibrillation induced during electrophysiological testing. The device also successfully detected and treated all 12 episodes of spontaneous, sustained ventricular tachyarrhythmia. (ClinicalTrials.gov numbers, NCT00399217 and NCT00853645.)


Assuntos
Desfibriladores Implantáveis , Cardiopatias/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Eletrocardiografia , Eletrodos Implantados , Desenho de Equipamento , Feminino , Cardiopatias/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Volume Sistólico , Adulto Jovem
10.
Circulation ; 116(25): 2952-9, 2007 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-18056531

RESUMO

BACKGROUND: We describe the first human experience with a permanently implantable, direct left atrial pressure (LAP) monitoring system in ambulatory patients with chronic heart failure. METHODS AND RESULTS: Eight patients with established heart failure and at least 1 heart failure hospitalization or unplanned visit for parenteral therapy in the last year underwent device implantation under fluoroscopic guidance. All subjects received aspirin 150 mg and clopidogrel 75 mg daily. Subjects measured LAP twice daily and attended a clinic regularly for data upload and device calibration. Right heart catheterization was performed at the time of device implantation and at 12 weeks. The device was implanted in all subjects with no procedural complications. At the 12-week follow-up, 87% of device LAP measurements were within +/-5 mm Hg of simultaneous pulmonary capillary wedge pressure readings over a wide range of pressures (1.6 to 71 mm Hg). Net drift corrected by calibration was -0.2+/-1.9 mm Hg/mo. During short-term follow-up, there were no device-related complications or systemic emboli. There were no deaths, no unplanned heart failure clinic visits, and no admissions for heart failure. CONCLUSIONS: Ambulatory monitoring of direct LAP with a new implantable device was well tolerated, feasible, and accurate at a short-term follow-up. Further follow-up and investigation are warranted to evaluate the clinical utility of LAP monitoring in patients with heart failure.


Assuntos
Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Monitorização Ambulatorial/instrumentação , Monitorização Ambulatorial/métodos , Próteses e Implantes , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Seguimentos , Átrios do Coração , Humanos , Masculino , Pressão , Transdutores