Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
2.
World Neurosurg ; 119: 257-261, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30096500

RESUMO

INTRODUCTION/OBJECTIVE: Hydrocephalus is a common neurosurgical disorder that can lead to significant disability or death if not promptly identified and treated. Data on the burden of hydrocephalus in low-income countries are limited, given a lack of radiologic resources for the diagnosis of this condition. Here, we present an analysis of patterns of hydrocephalus from a large sample of computed tomography (CT) scans of the head performed at a public hospital in rural Haiti, a low-income country in the Caribbean. METHODS: We analyzed reports from 3614 CT scans of the head performed between July 2013 and January 2016 for findings that were consistent with a diagnosis of hydrocephalus (report indicating "hydrocephalus," "ventriculomegaly," or "enlargement of the ventricles"). Extracted data included demographics, study indication, radiologic findings, and reported etiology of hydrocephalus. RESULTS: In total, 119 scans had findings concerning for hydrocephalus (3.5% of all scans, 6.3% of abnormal scans; age range 0-90 years; median age 35.5 years; 49.6% male). Pediatric patients (<18 years of age) accounted for 39% of cases. In total, 113 of 119 (95%) scans had indications for possible neurosurgical intervention. Among these 113 scans, 36 (30%) scans demonstrated communicating hydrocephalus, 66 (55%) scans demonstrated noncommunicating hydrocephalus (primarily due to intraventricular hemorrhage [27 scans, 23%] or brain tumors [24, 20%]), and 11 (9%) scans were indeterminate regarding whether the hydrocephalus was communicating versus noncommunicating. CONCLUSIONS: In a large sample of CTs performed in a rural low-income setting, hydrocephalus was common, predominantly noncommunicating, and often associated with potentially operable intracranial lesions. Data of this nature can inform research, policy, and clinical collaborations that strengthen the neurosurgical capacity of low-income countries.


Assuntos
Hidrocefalia/diagnóstico por imagem , Hidrocefalia/epidemiologia , Tomografia Computadorizada por Raios X , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Haiti/epidemiologia , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , População Rural , Adulto Jovem
3.
J Neurol Sci ; 379: 327-330, 2017 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-28716274

RESUMO

BACKGROUND: Neuroimaging is often unavailable in low-income countries, creating challenges for precise diagnosis of neurologic disease in individual patients, and impeding acquisition of precise neuroepidemiologic data for program and policy development. METHODS: We analyzed reports from 3614 head CTs performed between July 2013 and January 2016 at Hôpital Universitaire de Mirebalais, a public academic hospital in rural Haiti, extracting patients' age, study indication, and radiologic findings. RESULTS: The most common indications for head CT were headache (27%), trauma (19.9%), abnormal neurological exam (12.2%), and stroke (11.3%). The most common categories of neurologic abnormalities were traumatic (31%), vascular (25.8%), and infectious (12%). Of 291 strokes, 64% were ischemic (median age at diagnosis 60.8years, SD 17.4) and 36% were hemorrhagic (median age 52.0, SD 15.5). In patients undergoing head CT for seizures or epilepsy, 17.5% had evidence of neurocysticercosis. In patients with head trauma, 42.6% had intracranial hemorrhage or fracture. Atrophy was noted on 10% of CTs (median age 57.1; SD 23.8), and was characterized as out of proportion to age in 2% (median age 34.1, SD 15.3). CONCLUSIONS: Median age of stroke patients in this rural low-income population is lower than in high-income countries and proportion of stroke due to intracerebral hemorrhage is higher. Neurocysticercosis is present in nearly one fifth of patients with seizures/epilepsy. These findings can inform policies and programs for prevention and treatment of neurologic disease in low-income settings.


Assuntos
Cabeça/diagnóstico por imagem , Hospitais Universitários , População Rural/estatística & dados numéricos , Tomografia Computadorizada por Raios X , Adulto , Idoso , Humanos , Pessoa de Meia-Idade , Pobreza/estatística & dados numéricos , Adulto Jovem
4.
J Interv Card Electrophysiol ; 36(3): 217-22, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23196855

RESUMO

OBJECTIVE: This study aims to optimize coronary sinus (CS) computerized tomography (CT) imaging and evaluate its utility for preprocedural planning and intraoperative guidance by overlay of 3D reconstructed CS images on live fluoroscopy. BACKGROUND: Optimal CS lead placement for cardiac resynchronization therapy (CRT) remains challenging. Preprocedural knowledge of CS anatomy can significantly affect procedural outcome. Optimal CS imaging protocols by CT have not been well defined. METHODS: Seventeen consecutive CRT recipients underwent contrast-enhanced functional cardiac CT on a 64-slice scanner. The CS target branch closest to the most dyssynchronous LV segment was identified. 3D volume rendered CS images were superimposed onto live fluoroscopy via EP Navigator (Philips Healthcare, Best, The Netherlands) to guide CS cannulation and lead placement. The imaging protocol was optimized. RESULTS: CT images were successfully reconstructed and overlaid on live fluoroscopy in 16/17 patients. The overlay facilitated CS cannulation and lead placement into a predefined target branch. Excellent correlation between CT and angiographic CS anatomy was noted. By using the overlaid 3D CS as a road map, average total fluoroscopy time (14.56 ± 4.22 min) was significantly shorter when compared to historical controls. Total radiation exposure was significantly higher in the CT-guided group. Images obtained using double bolus injection and gated acquisition at 40 % of the cardiac cycle contained the most anatomical detail of the CS. CONCLUSION: Overlay of 3D CS anatomy defined by preprocedural cardiac CT is feasible. It allows planning of CRT implantation and live guidance of CS lead placement into a predefined target branch. Limiting the CT imaging to 40 % of the cardiac cycle phase provides optimal CS images and reduces radiation exposure. This approach may result in shorter procedural time and more optimal CS lead positioning. However, the concept remains to be confirmed by future studies.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Seio Coronário/diagnóstico por imagem , Eletrodos Implantados , Insuficiência Cardíaca/prevenção & controle , Ventrículos do Coração/diagnóstico por imagem , Radiografia Intervencionista/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Seio Coronário/cirurgia , Estudos de Viabilidade , Feminino , Insuficiência Cardíaca/cirurgia , Ventrículos do Coração/cirurgia , Humanos , Imageamento Tridimensional/métodos , Masculino , Implantação de Prótese/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
5.
Can Assoc Radiol J ; 62(4): 265-71, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20615659

RESUMO

OBJECTIVE: Benign breast masses, such as fibroadenomas, are common, and their management is variable, depending on symptoms and patient concerns. We undertook this study to determine the safety, efficacy, and patient acceptance of percutaneous excision of benign breast masses by using a hand-held vacuum-assisted device. METHODS: By using sonographic guidance, percutaneous removal was performed in 40 patients with 42 lesions by using a 9-gauge (n = 13) or 12-gauge (n = 29) probe (ATEC; Suros Surgical). Technical success, procedural complications, and patient experience were recorded at the time of excision and at 48 hours. Clinical, imaging, and/or surgical follow-up was obtained for 39 of 42 lesions (93%). Three of 42 lesions (7%) were lost to follow-up. RESULTS: Of 42 lesions, maximal diameters ranged from 0.6-4.0 cm (mean 1.6 cm), with lesion volumes between 0.05 and 11.2 mL (mean [SD] 1.4 ± 2.1 mL, median 7 mL). The procedure was well tolerated by all patients, and no residual mass was visible in any case at the conclusion of the procedure. All the patients preferred this approach to open surgical biopsy. After percutaneous excision, surgery was performed on 3 of 42 lesions (7%) for atypia (n = 2) or malignancy (n = 1), with a residual mass found only for the malignant case. Of the 26 of 42 lesions (62%) with imaging follow-up, 24 (92%) had no lesion recurrence. Overall, the procedure either completely removed the mass and/or relieved the patient's symptoms of a mass in 36 of 39 lesions (92%) for which clinical, imaging, and/or surgical follow-up was available. Three lesions were lost to follow-up. CONCLUSION: Ultrasound-guided percutaneous excision of benign breast masses is a safe, effective, and well-tolerated minimally invasive procedure for the diagnosis and removal of benign breast masses. It may serve as an alternative to surgical excision for women with a known benign or probably benign breast mass who desire excision but prefer to avoid surgery or who are poor surgical candidates.


Assuntos
Doenças Mamárias/cirurgia , Ultrassonografia de Intervenção , Vácuo , Adolescente , Adulto , Idoso , Biópsia , Doenças Mamárias/diagnóstico por imagem , Feminino , Humanos , Masculino , Mamografia , Pessoa de Meia-Idade , Satisfação do Paciente , Resultado do Tratamento
6.
Heart Rhythm ; 6(2): 231-7, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19187917

RESUMO

BACKGROUND: Three-dimensional rotational atriography (3DATG) was developed to supplement two-dimensional fluoroscopy with 3D volume reconstruction of the left atrium (LA), pulmonary veins (PV), and other structures. Until recently, 3DATG images could only be viewed separately and were not suitable to directly guide atrial fibrillation (AF) ablation. OBJECTIVE: The purpose of this study was to evaluate the feasibility and accuracy of intraprocedural 3DATG. METHODS: Three-dimensional rotational atriography with right atrial contrast injection was obtained using a Philips Allura Xper FD10 system in 30 patients with symptomatic AF who also underwent preprocedural computed tomographic (CT) scan. RESULTS: The majority (93%) of 3DATG image reconstructions were useful for guidance of catheter ablation. Nearly all PVs (94%), LA appendage (89%), and esophagus (100%) were successfully segmented. Measured PV ostial diameters compared using 3DATG and CT showed close concordance. Registration and re-registration of 3DATG overlay image was easily achieved with thoracic landmarks and validated by catheter placement demonstrating minimal discrepancy. Endoscopic views allowed for improved visualization of ostial position, dimensions, and navigation within the antrum. Lesion tagging on 3DATG overlay enhanced ablation guidance. Radiation exposure with 3DATG was significantly reduced compared with preprocedural CT scan (2.1 +/- 0.3 mSv vs 13.8 +/- 2.4 mSv, P <.001). CONCLUSION: Intraprocedural 3DATG imaging during AF ablation with online segmentation and superimposition on live fluoroscopy is feasible. Overlay provides valuable and accurate information on 3D surface outline and endoscopic PV location. Three-dimensional rotational atriography overlay is a new imaging method with reduced radiation exposure that may replace preprocedural CT scan for catheter navigation and ablation of AF.


Assuntos
Angiografia/instrumentação , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/instrumentação , Fluoroscopia/instrumentação , Imageamento Tridimensional/instrumentação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Meios de Contraste/administração & dosagem , Estudos de Viabilidade , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Doses de Radiação , Radiografia Intervencionista/instrumentação , Estatísticas não Paramétricas , Tomografia Computadorizada por Raios X
7.
AJR Am J Roentgenol ; 189(1): 152-4, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17579165

RESUMO

OBJECTIVE: As breast MRI has become more widely used, the need to biopsy suspicious lesions visible only on MRI has increased. A small percentage of these lesions are not amenable to MR-guided biopsy. We report our technique of CT-guided core needle biopsy of breast lesions. CONCLUSION: CT-guided core needle biopsy is a safe and effective method for sampling breast lesions visible only on MRI when MR-guided biopsy is not feasible.


Assuntos
Biópsia por Agulha/métodos , Neoplasias da Mama/diagnóstico , Imageamento por Ressonância Magnética/métodos , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Pessoa de Meia-Idade
8.
J Interv Card Electrophysiol ; 18(3): 217-23, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17516160

RESUMO

INTRODUCTION: Increasing use of catheter ablation in the left atrium (LA) requires understanding of substrate anatomy, especially with regard to potential damage to adjacent structures. METHODS AND RESULTS: We reviewed multidetector helical computed tomography (MDCT) imaging on 42 subjects, 26 imaged before planned LA ablation for atrial fibrillation (AF), and 16 without AF. LA volume and dimensions were larger in patients with AF (p < 0.05) and the spine and aorta (Ao) impressed the LA more frequently in the AF group. The esophagus (Eo) was the predominant feature on the posterior LA wall, contacting it in all patients. The Ao was in contact with the LA body or the left inferior pulmonary vein (PV) in 32 (76%) of 42 cases, and in 10 it ran along an indentation on the posterior aspect of the LA. The coronary sinus was adjacent to LA ablation sites, the azygos vein was rarely adjacent to those sites, and the left bronchus abutted the PV ostium but not the LA. Two patients had findings that directly impacted the ablation procedure: one patient had a dilated fluid filled Eo with esophageal stricture and underwent nasogastric decompression before ablation, and one was discovered to have an anomalous PV and underwent surgical repair. CONCLUSIONS: MDCT imaging identifies structures adjacent to the LA, which could be affected by ablation. Posterior LA topography can be influenced by the position of the Ao or by the proximity of the spine. Preprocedural imaging can characterize anatomic structures that could be vulnerable during ablation, and detect unusual pathology that can affect the treatment plan.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Ablação por Cateter , Átrios do Coração/diagnóstico por imagem , Mediastino/diagnóstico por imagem , Tomografia Computadorizada Espiral , Adulto , Idoso , Aortografia , Fibrilação Atrial/cirurgia , Esôfago/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Pulmonar/diagnóstico por imagem
9.
Virtual Mentor ; 9(11): 758-61, 2007 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-23228609
10.
AJR Am J Roentgenol ; 187(6): 1483-91, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17114541

RESUMO

OBJECTIVE: The purpose of this study was to prospectively assess the usefulness of computer-aided detection (CAD) in the interpretation of screening mammography and to provide the true sensitivity and specificity of this technique in a clinical setting. SUBJECTS AND METHODS: Over a 26-month period, 5,016 screening mammograms were interpreted without, and subsequently with, the assistance of the iCAD MammoReader detection system. Data collected for actionable findings included dominant feature (calcification, mass, asymmetry, architectural distortion), detection method (radiologist only, CAD only, or both radiologist and CAD), BI-RADS assessment code, associated histopathology for those undergoing biopsy, and tumor stage for malignant lesions. The study population was cross-checked against an independent reference standard to identify false-negative cases. RESULTS: Of the 5,016 cases, the recall rate increased from 12% to 14% with the addition of CAD. Of the 107 (2%) patients who underwent biopsy, 101 (94%) were prompted by the radiologist and six (6%) were prompted by CAD. Of the 124 biopsies performed on actionable findings in the 107 patients, findings in 79 (64%) were benign and in 45 (36%) were in situ or invasive carcinoma. Three study participants who were not recalled by the radiologist with the assistance of CAD developed cancer within 1 year of the screening mammogram and were considered to be false-negative cases. The radiologist detected 43 (90%) of the 48 total malignancies and 45 (94%) of the 48 malignancies with the assistance of CAD. CAD missed eight cancers that were detected by the radiologist, which presented as architectural distortions (n = 3), irregular masses (n = 4), and a circumscribed mass (n = 1). CAD detected two in situ cancers as a faint cluster of calcifications that had not been perceived by the radiologist and one mass that was dismissed by the radiologist, accounting for at least a 4.7% increase in cancer detection rate. Sensitivity of screening mammography with the use of CAD (94%) represented an absolute and relative 4% increase over the sensitivity of the radiologist alone (90%). Specificity of screening mammography with and without the use of CAD was 99%. CONCLUSION: Routine use of CAD while interpreting screening mammograms significantly increases recall rates, has no significant effect on positive predictive value for biopsy, and can increase cancer detection rate by at least 4.7% and sensitivity by at least 4%. This study provides "true" values for sensitivity and specificity for use of CAD in interpretation of screening mammography as measured prospectively in the context of a working clinical setting.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia/métodos , Adulto , Biópsia , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Programas de Rastreamento/métodos , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade
11.
Breast J ; 10(1): 27-32, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-14717756

RESUMO

It has been established that hormone replacement therapy (HRT) increases breast tissue density on mammography in up to 30% of women receiving treatment. The effects of selective estrogen receptor modulators (SERMs) on breast tissue have received limited attention, although there have been several reports of tamoxifen decreasing mammographic tissue density in some women undergoing adjuvant or prophylactic breast cancer treatment. We report a case of a premenopausal woman treated with tamoxifen for 5 years whose mammographic density decreased while on tamoxifen and returned to her baseline density following termination of the drug. A regression of breast tissue may be reflective of sensitivity to tamoxifen and possibly, indicative of therapeutic benefit associated with treatment. Furthermore, induction of a more radiolucent pattern by tamoxifen may independently benefit women by enhancing mammographic detection. The clinical significance of resumption of a dense breast pattern following discontinuation of tamoxifen remains to be determined.


Assuntos
Neoplasias da Mama/tratamento farmacológico , Mama/efeitos dos fármacos , Carcinoma Ductal de Mama/tratamento farmacológico , Moduladores Seletivos de Receptor Estrogênico/uso terapêutico , Tamoxifeno/uso terapêutico , Adulto , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Carcinoma Ductal de Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/patologia , Feminino , Humanos , Mamografia , Pré-Menopausa , Moduladores Seletivos de Receptor Estrogênico/farmacologia , Tamoxifeno/farmacologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...