Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Molecules ; 28(4)2023 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-36838614

RESUMO

Diamond is a promising material for the biomedical field, mainly due to its set of characteristics such as biocompatibility, strength, and electrical conductivity. Diamond can be synthesised in the laboratory by different methods, is available in the form of plates or films deposited on foreign substrates, and its morphology varies from microcrystalline diamond to ultrananocrystalline diamond. In this review, we summarise some of the most relevant studies regarding the adhesion of cells onto diamond surfaces, the consequent cell growth, and, in some very interesting cases, the differentiation of cells into neurons and oligodendrocytes. We discuss how different morphologies can affect cell adhesion and how surface termination can influence the surface hydrophilicity and consequent attachment of adherent proteins. At the end of the review, we present a brief perspective on how the results from cell adhesion and biocompatibility can make way for the use of diamond as biointerface.


Assuntos
Diamante , Diamante/química , Proliferação de Células , Adesão Celular , Diferenciação Celular/fisiologia
2.
Materials (Basel) ; 15(2)2022 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-35057131

RESUMO

Gallium nitride is a wide bandgap semiconductor material with high electric field strength and electron mobility that translate in a tremendous potential for radio-frequency communications and renewable energy generation, amongst other areas. However, due to the particular architecture of GaN high electron mobility transistors, the relatively low thermal conductivity of the material induces the appearance of localized hotspots that degrade the devices performance and compromise their long term reliability. On the search of effective thermal management solutions, the integration of GaN and synthetic diamond with high thermal conductivity and electric breakdown strength shows a tremendous potential. A significant effort has been made in the past few years by both academic and industrial players in the search of a technological process that allows the integration of both materials and the fabrication of high performance and high reliability hybrid devices. Different approaches have been proposed, such as the development of diamond/GaN wafers for further device fabrication or the capping of passivated GaN devices with diamond films. This paper describes in detail the potential and technical challenges of each approach and presents and discusses their advantages and disadvantages.

3.
Appl Opt ; 59(28): 8866-8877, 2020 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-33104572

RESUMO

The operating temperature plays a key role in the performance and lifetime of photonic integrated circuits (PICs). Miniaturization and increasing heat dissipation promote thermal crosstalk effects and pose additional challenges to the PIC designer. The European Photonics Industry Consortium recommends thermal modeling during design phase. However, a fully numerical optimization of a particular layout requires an unrealistically large number of simulations. Here, we propose a compromise approach: a set of carefully chosen simulations are performed with a multi-physics software. The obtained results are used to derive a linearized equivalent thermal circuit that can be used to maximize the power levels and to minimize the distance between the chosen components while guaranteeing the absence of a thermal crosstalk. For simplification, this model is derived considering a PIC with only two active components. Other parameters are varied, such as the material of the holder (silicon or diamond) and the layer of epoxy that is used to attach the PIC to the holder. The obtained circuit is used to determine the maximum dissipated power or the minimum distance between the components while keeping some predetermined specifications. The model can be extended to contain more elements or to include transient analysis of the temperature distribution.

4.
Appl Opt ; 58(22): 6126-6135, 2019 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-31503936

RESUMO

The thermal management of photonic integrated circuits (PICs) poses a few challenges at the packaging level. The integration of a PIC with a proper holder provides mechanical support and electrical interconnection, as well as spreading of the heat generated during PIC operation. This study proposes and evaluates the thermal behavior of silicon and diamond holders and estimates the impact of integrating them with PICs as a packaged system; to this end, the thermal profile of a PIC with distributed feedback lasers mounted on silicon or diamond holders was simulated for different power levels using ANSYS Mechanical software. The impact of the epoxy resin used to mount the PIC on the holder and the thermal crosstalk between the active components were also evaluated. Based on steady-state thermal analysis, when the PIC is assembled via wire bonding, the replacement of the silicon holder with a diamond holder brings only a marginal advantage. The choice of epoxy has a larger impact on the maximum PIC temperature and the thermal crosstalk between active components. Choosing a large-thermal-conductivity-value epoxy is thus a mandatory requirement in order to guarantee the proper thermal management of PICs and their corresponding holders.

5.
Sensors (Basel) ; 17(7)2017 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-28671594

RESUMO

Real-time monitoring of torque in a rotating shaft is not easy to implement with technologies such as optic fiber sensors or strain gages. Surface acoustic wave (SAW) sensors are wireless and passive and can be used to monitor strain in moving parts. Commercial solutions (sensors, antennas and interrogation unit) can easily be purchased from some companies; however, they are not customized and may not meet the specificity of the measurements. In order to evaluate the adequacy of commercial off-the-shelf (COTS) solutions, temperature and strain sensors fabricated by SENSeOR (Besançon, France) were mounted on a load cell. The sensors were calibrated using a thermal chamber and a universal testing machine. The load cell was then assembled together with a steel shaft that rotated at different speeds inside an oven. The commercial antennas were replaced with an RF (radio frequency) coupler and the sensors were interrogated with the commercial interrogation unit. The influence of rotation in the accuracy on the measurements, as well as the adequacy of the sensors structure, was evaluated. It can be concluded that SAW sensors can be used to measure temperature or torque in a rotating environment; however, some customization of the components is required in order to overcome the limitations posed by COTS sensing solutions.

6.
Adv Neonatal Care ; 13(6): 408-14, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24300959

RESUMO

Pediatric palliative care in Portugal is improving, but there is still additional work to do concerning programs or guidelines for this subject. In Portugal, physicians are the stakeholders in the decision-making process with reference to the transition to palliative care in the neonatal intensive care unit, and it was considered very important to raise their awareness and motivation about neonatal palliative care. Our research was based on Catlin and Carter's protocol from 2002 and the main goal was to assess neonatologists' willingness to build a palliative care and end-of-life protocol that could be acceptable nationwide. The survey used the Delphi technique and was developed in 3 rounds. The expert panel was composed of 57 participants who represented 41% of the Portuguese neonatologists. The study was conducted via the Internet, based in a researcher-created private Web site, and e-mail was used for data collection and feedback. Neonatologists agreed on 7 areas: (1) planning (medical education, resources, and local), (2) prenatal palliative care, (3) neonatal palliative care criteria, (4) the parents (presenting neonatal palliative care to parents, including then in the daily care of newborns and in family-centered care), (5) physicians' needs, (6) pain and symptom management, and (7) end-of-life care (withholding/withdrawing ventilation and hydration/nutrition).


Assuntos
Atitude do Pessoal de Saúde , Neonatologia/métodos , Cuidados Paliativos/métodos , Guias de Prática Clínica como Assunto , Assistência Terminal/métodos , Tomada de Decisões , Técnica Delphi , Humanos , Recém-Nascido , Unidades de Terapia Intensiva Neonatal , Manejo da Dor/métodos , Pais , Portugal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...