Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Mar Environ Res ; 186: 105922, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36812839

RESUMO

Functional aspects of biological communities influence ecosystem processes and it is urgent to understand how human disturbances affect functional diversity and ecosystem functions and services. Our purpose was to address the use of different functional metrics of nematode assemblages to evaluate the ecological status of tropical estuaries subjected to different human activities, aiming to advance and improve the knowledge about the usefulness of functional attributes as indicators of environmental quality. Three approaches were compared: functional diversity indexes, single trait, and multi traits using the Biological Traits Analysis. The RLQ + fourth-corner combined method was used to identify relationships among functional traits, inorganic nutrients, and metals concentrations. Lower values of FDiv, FSpe, and FOri indicate a convergence of functions, characterizing impacted conditions. A dominant set of traits was related to disturbance, mainly inorganic nutrient enrichment. All the approaches allowed for the detection of disturbed conditions, however, multi traits was the most sensitive one.


Assuntos
Ecossistema , Nematoides , Animais , Humanos , Biodiversidade , Biota , Estuários
2.
Environ Monit Assess ; 190(10): 617, 2018 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-30267160

RESUMO

This work proposes the quantification of Cr (VI) ions in natural waters in trace level, using activated alumina (Al2O3) as preconcentration support, controlled in-line dissolution of the solidified chromophore diphenylcarbazide after heat treatment and spectrophotometric detection. The manifold ensures high sensitivity of analytical response, good repeatability, and stability. In this work, optimization of experimental conditions of a flow injection system was chosen as the parameters for greater sensitivity and better selectivity. The selected optimized conditions were 0.30 mol L-1 for H2SO4 concentration, system flow rate as 0.40 mL min-1, sample injection volume of 192.50 µL, 2 min for preconcentration time, and 0.10 mol L-1 for eluent concentration. The analytical curves obtained for real sample analysis show linear range from 0.192 to 0.961 µM, linear correlation coefficient R = 0.9997 and LOD = 0.024 µM. The preconcentration factor of about four times was obtained through the passage of 800 µL of a standard solution containing 0.961 µM of Cr (VI) through mini-column of preconcentration followed by elution at 192.5 µL of NH4OH 0.1 mol L-1 solution. The solid chromogenic reagent presented high durability (weeks in daily use with mass of 0.0993 g) and good reproducibility in analytical signal. The reactivation of the mini-column of alumina should be executed after ten injections of eluent, using 800 µL of HCl 0.02 mol L-1 solution in flow through the same. Each cycle of injection and elution of the sample takes about 5 min on the proposed terms. Despite the length of each cycle still be high, low concentrations can be detected using a technique of relatively low cost. This is due in part, the association dissolution of the chromogenic reagent directly in the line and the preconcentration step. Another important factor is the economy of reagent chromogenic, low generation of reject contributing to better quality of the environment, and the high potential for applications to work in field.


Assuntos
Cromo/análise , Difenilcarbazida/química , Monitoramento Ambiental/métodos , Espectrofotometria/métodos , Óxido de Alumínio/análise , Temperatura Alta , Íons/análise , Reprodutibilidade dos Testes , Solubilidade
3.
Electrophoresis ; 36(3): 441-8, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25256669

RESUMO

In-channel amperometric detection combined with dual-channel microchip electrophoresis is evaluated using a two-electrode isolated potentiostat for reverse polarity separations. The device consists of two separate channels with the working and reference electrodes placed at identical positions relative to the end of the channel, enabling noise subtraction. In previous reports of this configuration, normal polarity and a three-electrode detection system were used. In the two-electrode detection system described here, the electrode in the reference channel acts as both the counter and reference. The effect of electrode placement in the channels on noise and detector response was investigated using nitrite, tyrosine, and hydrogen peroxide as model compounds. The effects of electrode material and size and type of reference electrode on noise and the potential shift of hydrodynamic voltammograms for the model compounds were determined. In addition, the performance of two- and three-electrode configurations using Pt and Ag/AgCl reference electrodes was compared. Although the signal was attenuated with the Pt reference, the noise was also significantly reduced. It was found that lower LOD were obtained for all three compounds with the dual-channel configuration compared to single-channel, in-channel detection. The dual-channel method was then used for the detection of nitrite in a dermal microdialysis sample obtained from a sheep following nitroglycerin administration.


Assuntos
Técnicas Eletroquímicas/instrumentação , Eletroforese em Microchip/instrumentação , Técnicas Eletroquímicas/métodos , Eletrodos , Eletroforese em Microchip/métodos , Desenho de Equipamento , Limite de Detecção , Microdiálise , Nitritos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA