Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Phys B ; 122(6): 173, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-32355420

RESUMO

The application of an interband cascade laser, ICL, to multi-mode absorption spectroscopy, MUMAS, in the mid-infrared region is reported. Measurements of individual mode linewidths of the ICL, derived from the pressure dependence of lineshapes in MUMAS signatures of single, isolated, lines in the spectrum of HCl, were found to be in the range 10-80 MHz. Multi-line spectra of methane were recorded using spectrally limited bandwidths, of approximate width 27 cm-1, defined by an interference filter, and consist of approximately 80 modes at spectral locations spanning the 100 cm-1 bandwidth of the ICL output. Calibration of the methane pressures derived from MUMAS data using a capacitance manometer provided measurements with an uncertainty of 1.1 %. Multi-species sensing is demonstrated by the simultaneous detection of methane, acetylene and formaldehyde in a gas mixture. Individual partial pressures of the three gases are derived from best fits of model MUMAS signatures to the data with an experimental error of 10 %. Using an ICL, with an inter-mode interval of ~10 GHz, MUMAS spectra were recorded at pressures in the range 1-10 mbar, and, based on the data, a potential minimum detection limit of the order of 100 ppmv is estimated for MUMAS at atmospheric pressure using an inter-mode interval of 80 GHz.

2.
Appl Opt ; 54(31): F1-7, 2015 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-26560596

RESUMO

We characterize the internal efficiency, internal loss, and optical gain versus current density in 7-stage interband cascade lasers operating at λ=3.1 and 3.45 µm using a cavity-length study of the external differential quantum efficiency (EDQE) and threshold current density at temperatures between 300 and 345 K. We find that the pronounced efficiency droop of the EDQE at high current densities is primarily due to an increase in the internal loss rather than a reduction in the internal efficiency. On the other hand, if the current density J is fixed, the temperature variation of the EDQE at that J is due primarily to a decrease of the internal efficiency. The gain versus current density is fit well by a logarithmic relationship, although the magnitude of the experimental gain is >20% below the theoretical estimate.

3.
Opt Lett ; 40(17): 4186-9, 2015 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-26368743

RESUMO

An interband cascade laser (ICL) operating at 3.7 µm has been used to perform multimode absorption spectroscopy, MUMAS, at scan rates up to 10 kHz. Line widths of individual modes in the range 10-80 MHz were derived from isolated lines in the MUMAS signatures of HCl. MUMAS data for methane covering a spectral range of 30 nm yielded a detection level of 30 µbar·m for 1 s measurement time at 100 Hz. Simultaneous detection of methane, acetylene, and formaldehyde in a gas mixture containing all three species is reported.

4.
Nat Commun ; 2: 585, 2011 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-22158440

RESUMO

The interband cascade laser differs from any other class of semiconductor laser, conventional or cascaded, in that most of the carriers producing population inversion are generated internally, at semimetallic interfaces within each stage of the active region. Here we present simulations demonstrating that all previous interband cascade laser performance has suffered from a significant imbalance of electron and hole densities in the active wells. We further confirm experimentally that correcting this imbalance with relatively heavy n-type doping in the electron injectors substantially reduces the threshold current and power densities relative to all earlier devices. At room temperature, the redesigned devices require nearly two orders of magnitude less input power to operate in continuous-wave mode than the quantum cascade laser. The interband cascade laser is consequently the most attractive option for gas sensing and other spectroscopic applications requiring low output power and minimum heat dissipation at wavelengths extending from 3 µm to beyond 6 µm.


Assuntos
Eletrônica/métodos , Desenho de Equipamento/métodos , Lasers Semicondutores , Simulação por Computador , Eletrônica/instrumentação , Elétrons , Desenho de Equipamento/instrumentação , Gases , Raios Infravermelhos , Luz , Teoria Quântica
5.
Biotechnol Prog ; 15(2): 278-82, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10194405

RESUMO

Hyoscyamus muticus hairy root segments were infected with Agrobacterium tumefaciens ASE containing the binary vector pCGN1548 with a green fluorescent protein (GFP) reporter gene under the control of the CaMV 35S promoter. The roots were incubated on callus-inducing medium to generate transformed cells. Transformants were selected on medium containing 50 and 100 mg/L kanamycin and screened by visual inspection for GFP expression. Highly fluorescent cells were incubated on phytohormone-free medium for regeneration of the hairy root phenotype. This infection technique can be applied directly to existing hairy root cultures which have been previously characterized and selected for desirable physiological traits. These studies also indicate that GFP is not toxic to H. muticus plant tissue and that H. muticus hairy roots have minimal autofluorescence which allows for clear observation of GFP.


Assuntos
Raízes de Plantas/microbiologia , Rhizobium/genética , Transformação Genética , Técnicas de Cultura de Células/métodos , Proteínas de Fluorescência Verde , Indicadores e Reagentes/metabolismo , Proteínas Luminescentes/genética , Proteínas Luminescentes/metabolismo , Raízes de Plantas/genética , Proteínas Recombinantes/genética , Proteínas Recombinantes/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...