Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 14(1): 1864, 2024 01 22.
Artigo em Inglês | MEDLINE | ID: mdl-38253772

RESUMO

The left atrium (LA) hemodynamic indices hold prognostic value in various cardiac diseases and disorders. To understand the mechanisms of these conditions and to assess the performance of cardiac devices and interventions, in vitro models can be used to replicate the complex physiological interplay between the pulmonary veins, LA, and left ventricle. In this study, a comprehensive and adaptable in vitro model was created. The model includes a flexible LA made from silicone and allows distinct control over the systolic and diastolic functions of both the LA and left ventricle. The LA was mechanically matched with porcine LAs through expansion tests. Fluid dynamic measures were validated against the literature and pulmonary venous flows recorded on five healthy individuals using magnetic resonance flow imaging. Furthermore, the fluid dynamic measures were also used to construct LA pressure-volume loops. The in vitro pressure and flow recordings expressed a high resemblance to physiological waveforms. By decreasing the compliance of the LA, the model behaved realistically, elevating the a- and v-wave peaks of the LA pressure from 12 to 19 mmHg and 22 to 26 mmHg, respectively, while reducing the S/D ratio of the pulmonary venous flowrate from 1.5 to 0.3. This model provides a realistic platform and framework for developing and evaluating left heart procedures and interventions.


Assuntos
Apêndice Atrial , Cardiopatias , Humanos , Animais , Suínos , Hidrodinâmica , Átrios do Coração/diagnóstico por imagem , Ventrículos do Coração
2.
Ultrasound Med Biol ; 45(7): 1708-1720, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31060859

RESUMO

Prosthetic mechanical valves are the elective choice in mitral valve (MV) replacement, because of their reliability and easiness of implantation. However, these prostheses can suffer from complications, the major one being prosthetic mitral valve thrombosis (PMVT). In these cases, transthoracic doppler echocardiogram (TDE) is the standard diagnostic workup for diagnosis of valve malfunction. The American Society of Echocardiography (ASE) indicates the possible TDE-derived indexes, which can help in identifying insurgence of MV replacement complications. Unfortunately, in some cases, it is not possible to detect PMVT based on these criteria. In these cases, we speak of Doppler silent thrombosis and only more accurate and invasive analyses, such as fluoroscopy, allow for a correct diagnosis. In this work, computational fluid dynamic models were implemented to simulate valve fluid dynamics in different clinical scenarios in order to improve the reliability of PMVT diagnosis based on TDE. In detail, seven mechanical valve configurations, associated to different potential thrombotic conditions (symmetric and asymmetric stenosis), were designed and tested using five pathologic transmitral velocity profile, extracted from real TDE images; to obtain the flow rate profiles, each TDE velocity profile was scaled to yield a mean flow rate (MFR) of 4, 5 and 6 L/min, respectively. As a result, 105 (7 × 5 × 3) synthetic cases, accounting for different velocity profiles, MFRs and valve configurations, were simulated. TDE-derived indexes were calculated according to the ASE guidelines that were extracted. Advanced statistical methods were applied to propose a new diagnostic algorithm for detecting PMVT. Our results showed that there isn't any significant difference between symmetric and asymmetric stenosis, probe location and flow rate waveform and confirmed that the single modality diagnostic is not able to predict thrombosis in a relevant number of cases, referable to mild and mild-severe stenosis cases. To overcome the problem, a novel multi-parametric discrete score based on the designed diagnostic algorithm was attained and tested; the percentage of stenosis (POS) was predicted with an accuracy rate of 90.5%. Even more interestingly, the error rate of 9.5% is related to four false positive cases corresponding to mild stenosis (POS = 15%) which were erroneously classified as mild-severe stenosis. No false negatives were obtained. Our results suggest that a reliable estimation must take into account the mean flow rate as well as the transmitral velocity profile in order to provide a correct diagnosis.


Assuntos
Ecocardiografia Doppler/métodos , Próteses Valvulares Cardíacas , Estenose da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Trombose Venosa/diagnóstico por imagem , Humanos , Valva Mitral/fisiopatologia , Estenose da Valva Mitral/fisiopatologia , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Trombose Venosa/fisiopatologia
3.
J Biomech Eng ; 141(10)2019 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-31053843

RESUMO

Prosthetic valve thrombosis (PVT) is a serious complication affecting prosthetic heart valves. The transvalvular mean pressure gradient (MPG) derived by Doppler echocardiography is a crucial index to diagnose PVT but may result in false negatives mainly in case of bileaflet mechanical valves (BMVs) in mitral position. This may happen because MPG estimation relies on simplifying assumptions on the transvalvular fluid dynamics or because Doppler examination is manual and operator dependent. A deeper understanding of these issues may allow for improving PVT diagnosis and management. To this aim, we used in vitro and fluid-structure interaction (FSI) modeling to simulate the function of a real mitral BMV in different configurations: normally functioning and stenotic with symmetric and completely asymmetric leaflet opening, respectively. In each condition, the MPG was measured in vitro, computed directly from FSI simulations and derived from the corresponding velocity field through a Doppler-like postprocessing approach. Following verification versus in vitro data, MPG computational data were analyzed to test their dependency on the severity of fluid-dynamic derangements and on the measurement site. Computed MPG clearly discriminated between normally functioning and stenotic configurations. They did not depend markedly on the site of measurement, yet differences below 3 mmHg were found between MPG values at the central and lateral orifices of the BMV. This evidence suggests a mild uncertainty of the Doppler-based evaluation of the MPG due to probe positioning, which yet may lead to false negatives when analyzing subjects with almost normal MPG.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...