Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Circulation ; 101(2): 125-30, 2000 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-10637197

RESUMO

BACKGROUND: Although improved epicardial blood flow (as assessed with either TIMI flow grades or TIMI frame count) has been related to reduced mortality after administration of thrombolytic drugs, the relationship of myocardial perfusion (as assessed on the coronary arteriogram) to mortality has not been examined. METHODS AND RESULTS: A new, simple angiographic method, the TIMI myocardial perfusion (TMP) grade, was used to assess the filling and clearance of contrast in the myocardium in 762 patients in the TIMI (Thrombolysis In Myocardial Infarction) 10B trial, and its relationship to mortality was examined. TMP grade 0 was defined as no apparent tissue-level perfusion (no ground-glass appearance of blush or opacification of the myocardium) in the distribution of the culprit artery; TMP grade 1 indicates presence of myocardial blush but no clearance from the microvasculature (blush or a stain was present on the next injection); TMP grade 2 blush clears slowly (blush is strongly persistent and diminishes minimally or not at all during 3 cardiac cycles of the washout phase); and TMP grade 3 indicates that blush begins to clear during washout (blush is minimally persistent after 3 cardiac cycles of washout). There was a mortality gradient across the TMP grades, with mortality lowest in those patients with TMP grade 3 (2.0%), intermediate in TMP grade 2 (4.4%), and highest in TMP grades 0 and 1 (6.0%; 3-way P=0.05). Even among patients with TIMI grade 3 flow in the epicardial artery, the TMP grades allowed further risk stratification of 30-day mortality: 0.73% for TMP grade 3; 2.9% for TMP grade 2; 5.0% for TMP grade 0 or 1 (P=0.03 for TMP grade 3 versus grades 0, 1, and 2; 3-way P=0.066). TMP grade 3 flow was a multivariate correlate of 30-day mortality (OR 0.35, 95% CI 0.12 to 1.02, P=0.054) in a multivariate model that adjusted for the presence of TIMI 3 flow (P=NS), the corrected TIMI frame count (OR 1.02, P=0.06), the presence of an anterior myocardial infarction (OR 2.3, P=0.03), pulse rate on admission (P=NS), female sex (P=NS), and age (OR 1.1, P<0.001). CONCLUSIONS: Impaired perfusion of the myocardium on coronary arteriography by use of the TMP grade is related to a higher risk of mortality after administration of thrombolytic drugs that is independent of flow in the epicardial artery. Patients with both normal epicardial flow (TIMI grade 3 flow) and normal tissue level perfusion (TMP grade 3) have an extremely low risk of mortality.


Assuntos
Antifibrinolíticos/uso terapêutico , Circulação Coronária/efeitos dos fármacos , Infarto do Miocárdio/tratamento farmacológico , Infarto do Miocárdio/fisiopatologia , Idoso , Angiografia Coronária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/mortalidade , Pericárdio/fisiopatologia , Ensaios Clínicos Controlados Aleatórios como Assunto , Medição de Risco/métodos
2.
J Am Coll Cardiol ; 34(4): 974-82, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10520778

RESUMO

OBJECTIVES AND BACKGROUND: While attention has focused on coronary blood flow in the culprit artery in acute myocardia infarction (MI), flow in the nonculprit artery has not been studied widely, in part because it has been assumed to be normal. We hypothesized that slower flow in culprit arteries, larger territories infarcted and hemodynamic perturbations may be associated with slow flow in nonculprit arteries. METHODS: The number of frames for dye to first reach distal landmarks (corrected TIMI [Thrombolysis in Acute Myocardial Infarction] frame count [CTFC]) were counted in 1,817 nonculprit arteries from the TIMI 4, 10A, 10B and 14 thrombolytic trials. RESULTS: Nonculprit artery flow was slowed to 30.9 +/- 15.0 frames at 90 min after thrombolytic administration, which is 45% slower than normal flow in the absence of acute MI (21 +/- 3.1, p < 0.0001). Patients with TIMI grade 3 flow in the culprit artery had faster nonculprit artery CTFCs than those patients with TIMI grades 0, 1 or 2 flow (29.1 +/- 13.7, n = 1,050 vs. 33.3 +/- 16.1, n = 752, p < 0.0001). The nonculprit artery CTFC improved between 60 and 90 min (3.3 +/- 17.9 frames, n = 432, p = 0.0001), and improvements were related to improved culprit artery flow (p = 0.0005). Correlates of slower nonculprit artery flow included a pulsatile flow pattern (i.e., systolic flow reversal) in the nonculprit artery (p < 0.0001) and in the culprit artery (p = 0.01), a left anterior descending artery culprit artery location (p < 0.0001), a decreased systolic blood pressure (p = 0.01), a decreased ventriculographic cardiac output (p = 0.02), a decreased double product (p = 0.0002), a greater percent diameter stenosis of the nonculprit artery (p = 0.01) and a greater percent of the culprit artery bed lying distal to the stenosis (p = 0.04). Adjunctive percutaneous transluminal coronary angioplasty (PTCA) of the culprit artery restored a culprit artery CTFC (30.4 +/- 22.2) that was similar to that in the nonculprit artery at 90 min (30.2 +/- 13.5), but both were slower than normal CTFCs (21 +/- 3.1, p < 0.0005 for both). If flow in the nonculprit artery was abnormal (CTFC > or = 28 frames) then the CTFC after PTCA in the culprit artery was 17% slower (p = 0.01). Patients who died had slower global CTFCs (mean CTFC for the three arteries) than patients who survived (46.8 +/- 21.3, n = 47 vs. 39.4 +/- 16.7, n = 1,055, p = 0.02). CONCLUSIONS: Acute MI slows flow globally, and slower global flow is associated with adverse outcomes. Relief of the culprit artery stenosis by PTCA restored culprit artery flow to that in the nonculprit artery, but both were 45% slower than normal flow.


Assuntos
Angiografia Coronária , Circulação Coronária/fisiologia , Infarto do Miocárdio/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Angioplastia Coronária com Balão , Velocidade do Fluxo Sanguíneo/efeitos dos fármacos , Velocidade do Fluxo Sanguíneo/fisiologia , Circulação Coronária/efeitos dos fármacos , Relação Dose-Resposta a Droga , Método Duplo-Cego , Feminino , Fibrinolíticos/uso terapêutico , Hemodinâmica/efeitos dos fármacos , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica/efeitos dos fármacos , Contração Miocárdica/fisiologia , Infarto do Miocárdio/tratamento farmacológico , Estudos Prospectivos , Valores de Referência , Terapia Trombolítica , Resultado do Tratamento
3.
J Thromb Thrombolysis ; 7(3): 287-302, 1999 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10375390

Assuntos
Cardiologia/métodos , Inibidores da Agregação Plaquetária/uso terapêutico , Agregação Plaquetária/efeitos dos fármacos , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/antagonistas & inibidores , Abciximab , Administração Oral , Adulto , Idoso , Angina Instável/tratamento farmacológico , Angina Instável/terapia , Angioplastia Coronária com Balão , Anticorpos Monoclonais/efeitos adversos , Anticorpos Monoclonais/uso terapêutico , Aspirina/farmacologia , Ensaios Clínicos como Assunto , Doença das Coronárias/sangue , Doença das Coronárias/tratamento farmacológico , Doença das Coronárias/prevenção & controle , Doença das Coronárias/terapia , Método Duplo-Cego , Embolia/prevenção & controle , Eptifibatida , Feminino , Fibrinolíticos/efeitos adversos , Fibrinolíticos/uso terapêutico , Seguimentos , Previsões , Hemorragia/induzido quimicamente , Humanos , Fragmentos Fab das Imunoglobulinas/efeitos adversos , Fragmentos Fab das Imunoglobulinas/uso terapêutico , Masculino , Metanálise como Assunto , Pessoa de Meia-Idade , Estudos Multicêntricos como Assunto , Infarto do Miocárdio/tratamento farmacológico , Infarto do Miocárdio/terapia , Peptídeos/efeitos adversos , Peptídeos/uso terapêutico , Inibidores da Agregação Plaquetária/administração & dosagem , Inibidores da Agregação Plaquetária/efeitos adversos , Inibidores da Agregação Plaquetária/farmacologia , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/química , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/imunologia , Estudos Prospectivos , Risco , Stents , Relação Estrutura-Atividade , Tirofibana , Resultado do Tratamento , Tirosina/efeitos adversos , Tirosina/análogos & derivados , Tirosina/uso terapêutico
4.
Am Heart J ; 137(6): 1179-84, 1999 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10347349

RESUMO

BACKGROUND: The Thrombolysis in Myocardial Infarction (TIMI) Study Group originally defined TIMI grade 3 flow (complete perfusion) as antegrade flow into the bed distal to the obstruction that occurs as promptly as antegrade flow into the bed proximal to the obstruction. Recently, several groups have defined TIMI grade 3 flow as opacification of the coronary artery within 3 cardiac cycles. METHODS AND RESULTS: On the basis of heart rate data at the time of the cardiac catheterization and the time for dye to go down the artery (TIMI frame count/30 = seconds), we estimated the number of patients who would meet the 3 cardiac cycle criterion and compared this with the number of patients with TIMI grade 3 flow by using the original definition in 1157 patients from 3 recent TIMI trials (10 A, 10B, and 14). In 74 patients without acute myocardial infarction and normal coronary arteries, the fraction of a cardiac cycle required for dye to traverse the artery was a mean of 0.93 +/- 0.34 cardiac cycles (n = 74) (median 0.80, minimum 0.44, maximum 2.1, none >3.0 cycles). The mean heart rate at 90 minutes after thrombolysis in the TIMI 14 trial was 79.6 +/- 16.8 beats/min (n = 194), and the duration of 3 cardiac cycles was a mean of 2.36 seconds, or a TIMI frame count of 70.8 frames. In all trials, the rate of TIMI grade 3 flow was 57.3% (n = 663/1157) with the original definition and 66.8% (n = 743/1113) with the <3 cardiac cycle definition (P <.001). CONCLUSIONS: A duration of 3 cardiac cycles for dye to traverse the artery lies approximately 6 SD above that observed in normal coronary arteries. A 3 cardiac cycle definition of TIMI grade 3 flow results in rates of normal perfusion that are approximately 10% higher than if the original definition of TIMI grade 3 flow is applied. Application of this simple correction factor may help place data reported with the 3 cardiac cycle definition of TIMI grade 3 flow in context.


Assuntos
Angiografia Coronária , Circulação Coronária , Infarto do Miocárdio/diagnóstico por imagem , Terapia Trombolítica , Cineangiografia/estatística & dados numéricos , Ensaios Clínicos como Assunto , Meios de Contraste , Angiografia Coronária/estatística & dados numéricos , Frequência Cardíaca , Humanos , Infarto do Miocárdio/tratamento farmacológico , Infarto do Miocárdio/fisiopatologia , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...