1.
Water Sci Technol ; 63(11): 2598-604, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22049754

RESUMO

As part of a research & development project commissioned by the Land of North Rhine-Westphalia's Ministry for the Environment and Nature Conservation, Agriculture and Consumer Protection (MUNLV) an examination is being carried out of the general possibilities for centralised and decentralised treatment storm water runoff to be discharged into (canalised) receiving waters and the costs ensuing from this. The examination of the different options is being carried out under real conditions, with the Briller Creek (Wuppertal/Germany) and Müggen Creek (Remscheid/Germany) catchment areas being used as models. The range of investigations deals with a comparison between 'decentralised, semicentralised, centralised' storm water treatment, centralised storm water treatment involving a separate sewer and parameter-specific pollution based storm water runoff control. In the framework of the research project each of the variants is to be elaborated and the costs are to be calculated so as to permit a comparison between the different system designs. In particular, the investigations are to take into account the actual requirements to be met by storm water drainage systems involving separate sewage systems.


Assuntos
Engenharia Sanitária/economia , Engenharia Sanitária/métodos , Eliminação de Resíduos Líquidos/economia , Eliminação de Resíduos Líquidos/métodos , Poluentes Químicos da Água/química , Purificação da Água/instrumentação , Análise Custo-Benefício , Monitoramento Ambiental , Purificação da Água/métodos
2.
Water Sci Technol ; 63(10): 2287-93, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21977651

RESUMO

'Classical' real-time control (RTC) strategies in sewer systems are based on water level and flow measurements with the goal of activation of retention volume. The control system rule of 'clean (storm water) runoff into the receiving water - polluted runoff into the treatment plant' has been thwarted by rough operating conditions and lack of measurements. Due to the specific boundary conditions in the city of Wuppertal's separate sewer system (clean stream water is mixed with polluted storm water runoff) a more sophisticated--pollution-based--approach was needed. In addition the requirements to be met by the treatment of storm water runoff have become more stringent in recent years. To separate the highly-polluted storm water runoff during rain events from the cleaner stream flow a pollution-based real-time control (P-RTC) system was developed and installed. This paper describes the measurement and P-RTC equipment, the definition of total suspended solids as the pollution-indicating parameter, the serviceability of the system, and also gives a cost assessment. A sensitivity analysis and pollution load calculations have been carried out in order to improve the P-RTC algorithm. An examination of actual measurements clearly shows the ecological and economic advantages of the P-RTC strategy.


Assuntos
Drenagem Sanitária , Poluição da Água/análise , Inundações , Espectrofotometria Ultravioleta
3.
Water Sci Technol ; 60(4): 859-67, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19700824

RESUMO

In some cities, industrial enterprises' discharges into municipal sewage systems have a major impact on the quantity and quality of inflows to the municipal treatment plants. In many cases, industrial discharges stand out on account of the great fluctuations in their volumetric rates of flow, pollution loads and temperatures. As a result, these discharges put a great strain on the sewage system, the treatment plant, and ultimately the receiving waters. The enterprises concerned have to pay the treatment plant operators fees based on the load and/or volume discharged. In most cases, qualitative monitoring operations merely consist of spot checks. This means that continuously surveillance is not possible and infringements of the permissible limit values are only discovered by accident. If impermissible discharges are carried out that may be susceptible to causing a treatment plant failure, the rapid initiation of countermeasures is not possible. Hence, spectrometer probes and mobile flowmeters were used in order to determine volumetric rates of flow, COD concentrations, and ultimately the loads discharged. The possibilities for, and limits to, online monitoring as well as shortcomings of spot-checks are discussed in the course of this paper, which also includes an uncertainty analysis.


Assuntos
Cidades , Resíduos Industriais/análise , Sistemas On-Line , Esgotos/análise , Calibragem , Oxigênio/isolamento & purificação , Análise Espectral , Poluentes Químicos da Água/análise , Poluição da Água
4.
Zentralbl Veterinarmed A ; 46(10): 621-31, 1999 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-10638300

RESUMO

After 14C-labelled cortisol infusion in ponies and pigs, faecal samples were collected. Extraction of 0.5 g faeces with 5 ml 80-90% methanol yielded the highest radioactivity in the supernatant. Most of the metabolites were ether soluble. After high performance liquid chromatography (HPLC), the presence of immunoreactive metabolites was demonstrated by measuring each HPLC fraction using enzyme immunoassays for cortisol, corticosterone and 11-oxoaetiocholanolone. Only the assay for 11-oxoaetiocholanolone revealed peaks with co-eluting radioactivity. For biological validation of the test system, adrenocorticotrophic hormone (ACTH) and dexamethasone were injected intravenously successively in both species (n = 6). Cortisol concentration in blood and the 11-oxoaetiocholanolone immunoreactive substances in faeces were determined. In horse faeces, basal values of 2.3-35.2 nmol/kg were measured. After ACTH administration, an increase (more than 200% above basal values) of these metabolites was seen about 1 day after ACTH administration. After dexamethasone injection the levels decreased, reaching minimum concentrations 2 days after administration. In pigs, an increase in these metabolites was measured in only three animals after ACTH; dexamethasone did not cause a decrease. The stability of the samples after defecation was tested by storing samples from cows, horses and pigs at room temperature. It was shown that there was a significant increase in the concentration of measured cortisol metabolites in bovine, equine and porcine faeces after storage for 1 h, 4 h and 24 h, respectively. In frozen samples this effect was diminished after thawing samples at 40 degrees C; thawing the samples at 95 degrees C prevented an increase in immunoreactive substances.


Assuntos
Androstanos/análise , Bovinos/metabolismo , Fezes/química , Glucocorticoides/metabolismo , Cavalos/metabolismo , Suínos/metabolismo , Animais , Feminino , Hidrocortisona/biossíntese , Técnicas Imunoenzimáticas , Masculino
SELEÇÃO DE REFERÊNCIAS