Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 9(1): 13434, 2019 09 17.
Artigo em Inglês | MEDLINE | ID: mdl-31530855

RESUMO

Our research team previously developed an accelerometry-based device, which can be worn on the waist during daily life activities and detects the occurrence of dyskinesia in patients with Parkinson's disease. The goal of this study was to analyze the magnitude of correlation between the numeric output of the device algorithm and the results of the Unified Dyskinesia Rating Scale (UDysRS), administered by a physician. In this study, 13 Parkinson's patients, who were symptomatic with dyskinesias, were monitored with the device at home, for an average period of 30 minutes, while performing normal daily life activities. Each patient's activity was simultaneously video-recorded. A physician was in charge of reviewing the recorded videos and determining the severity of dyskinesia through the UDysRS for every patient. The sensor device yielded only one value for dyskinesia severity, which was calculated by averaging the recorded device readings. Correlation between the results of physician's assessment and the sensor output was analyzed with the Spearman's correlation coefficient. The correlation coefficient between the sensor output and UDysRS result was 0.70 (CI 95%: 0.33-0.88; p = 0.01). Since the sensor was located on the waist, the correlation between the sensor output and the results of the trunk and legs scale sub-items was calculated: 0.91 (CI 95% 0.76-0.97: p < 0.001). The conclusion is that the magnitude of dyskinesia, as measured by the tested device, presented good correlation with that observed by a physician.


Assuntos
Discinesias/etiologia , Monitorização Fisiológica/métodos , Doença de Parkinson/fisiopatologia , Acelerometria/instrumentação , Acelerometria/métodos , Idoso , Algoritmos , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/instrumentação , Gravação em Vídeo , Dispositivos Eletrônicos Vestíveis
2.
Gait Posture ; 59: 1-6, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28963889

RESUMO

The treatment of Parkinson's disease (PD) with levodopa is very effective. However, over time, motor complications (MCs) appear, restricting the patient from leading a normal life. One of the most disabling MCs is ON-OFF fluctuations. Gathering accurate information about the clinical status of the patient is essential for planning treatment and assessing its effect. Systems such as the REMPARK system, capable of accurately and reliably monitoring ON-OFF fluctuations, are of great interest. OBJECTIVE: To analyze the ability of the REMPARK System to detect ON-OFF fluctuations. METHODS: Forty-one patients with moderate to severe idiopathic PD were recruited according to the UK Parkinson's Disease Society Brain Bank criteria. Patients with motor fluctuations, freezing of gait and/or dyskinesia and who were able to walk unassisted in the OFF phase, were included in the study. Patients wore the REMPARK System for 3days and completed a diary of their motor state once every hour. RESULTS: The record obtained by the REMPARK System, compared with patient-completed diaries, demonstrated 97% sensitivity in detecting OFF states and 88% specificity (i.e., accuracy in detecting ON states). CONCLUSION: The REMPARK System detects an accurate evaluation of ON-OFF fluctuations in PD; this technology paves the way for an optimisation of the symptomatic control of PD motor symptoms as well as an accurate assessment of medication efficacy.


Assuntos
Monitorização Fisiológica/métodos , Transtornos Motores/diagnóstico , Doença de Parkinson/diagnóstico , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/instrumentação , Transtornos Motores/etiologia , Doença de Parkinson/complicações , Projetos Piloto , Estudos Prospectivos , Sensibilidade e Especificidade
4.
Front Neurol ; 8: 431, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28919877

RESUMO

BACKGROUND: Our group earlier developed a small monitoring device, which uses accelerometer measurements to accurately detect motor fluctuations in patients with Parkinson's (On and Off state) based on an algorithm that characterizes gait through the frequency content of strides. To further validate the algorithm, we studied the correlation of its outputs with the motor section of the Unified Parkinson's Disease Rating Scale part-III (UPDRS-III). METHOD: Seventy-five patients suffering from Parkinson's disease were asked to walk both in the Off and the On state while wearing the inertial sensor on the waist. Additionally, all patients were administered the motor section of the UPDRS in both motor phases. Tests were conducted at the patient's home. Convergence between the algorithm and the scale was evaluated by using the Spearman's correlation coefficient. RESULTS: Correlation with the UPDRS-III was moderate (rho -0.56; p < 0.001). Correlation between the algorithm outputs and the gait item in the UPDRS-III was good (rho -0.73; p < 0.001). The factorial analysis of the UPDRS-III has repeatedly shown that several of its items can be clustered under the so-called Factor 1: "axial function, balance, and gait." The correlation between the algorithm outputs and this factor of the UPDRS-III was -0.67 (p < 0.01). CONCLUSION: The correlation achieved by the algorithm with the UPDRS-III scale suggests that this algorithm might be a useful tool for monitoring patients with Parkinson's disease and motor fluctuations.

5.
Sensors (Basel) ; 17(4)2017 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-28398265

RESUMO

Inertial measurement units (IMUs) are devices used, among other fields, in health applications, since they are light, small and effective. More concretely, IMUs have been demonstrated to be useful in the monitoring of motor symptoms of Parkinson's disease (PD). In this sense, most of previous works have attempted to assess PD symptoms in controlled environments or short tests. This paper presents the design of an IMU, called 9 × 3, that aims to assess PD symptoms, enabling the possibility to perform a map of patients' symptoms at their homes during long periods. The device is able to acquire and store raw inertial data for artificial intelligence algorithmic training purposes. Furthermore, the presented IMU enables the real-time execution of the developed and embedded learning models. Results show the great flexibility of the 9 × 3, storing inertial information and algorithm outputs, sending messages to external devices and being able to detect freezing of gait and bradykinetic gait. Results obtained in 12 patients exhibit a sensitivity and specificity over 80%. Additionally, the system enables working 23 days (at waking hours) with a 1200 mAh battery and a sampling rate of 50 Hz, opening up the possibility to be used for other applications like wellbeing and sports.


Assuntos
Doença de Parkinson , Algoritmos , Marcha , Humanos
6.
PLoS One ; 12(2): e0171764, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28199357

RESUMO

Among Parkinson's disease (PD) symptoms, freezing of gait (FoG) is one of the most debilitating. To assess FoG, current clinical practice mostly employs repeated evaluations over weeks and months based on questionnaires, which may not accurately map the severity of this symptom. The use of a non-invasive system to monitor the activities of daily living (ADL) and the PD symptoms experienced by patients throughout the day could provide a more accurate and objective evaluation of FoG in order to better understand the evolution of the disease and allow for a more informed decision-making process in making adjustments to the patient's treatment plan. This paper presents a new algorithm to detect FoG with a machine learning approach based on Support Vector Machines (SVM) and a single tri-axial accelerometer worn at the waist. The method is evaluated through the acceleration signals in an outpatient setting gathered from 21 PD patients at their home and evaluated under two different conditions: first, a generic model is tested by using a leave-one-out approach and, second, a personalised model that also uses part of the dataset from each patient. Results show a significant improvement in the accuracy of the personalised model compared to the generic model, showing enhancement in the specificity and sensitivity geometric mean (GM) of 7.2%. Furthermore, the SVM approach adopted has been compared to the most comprehensive FoG detection method currently in use (referred to as MBFA in this paper). Results of our novel generic method provide an enhancement of 11.2% in the GM compared to the MBFA generic model and, in the case of the personalised model, a 10% of improvement with respect to the MBFA personalised model. Thus, our results show that a machine learning approach can be used to monitor FoG during the daily life of PD patients and, furthermore, personalised models for FoG detection can be used to improve monitoring accuracy.


Assuntos
Acelerometria/métodos , Doença de Parkinson/fisiopatologia , Máquina de Vetores de Suporte , Caminhada , Atividades Cotidianas , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
7.
Artif Intell Med ; 67: 47-56, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26831150

RESUMO

BACKGROUND: After several years of treatment, patients with Parkinson's disease (PD) tend to have, as a side effect of the medication, dyskinesias. Close monitoring may benefit patients by enabling doctors to tailor a personalised medication regimen. Moreover, dyskinesia monitoring can help neurologists make more informed decisions in patient's care. OBJECTIVE: To design and validate an algorithm able to be embedded into a system that PD patients could wear during their activities of daily living with the purpose of registering the occurrence of dyskinesia in real conditions. MATERIALS AND METHODS: Data from an accelerometer positioned in the waist are collected at the patient's home and are annotated by experienced clinicians. Data collection is divided into two parts: a main database gathered from 92 patients used to partially train and to evaluate the algorithms based on a leave-one-out approach and, on the other hand, a second database from 10 patients which have been used to also train a part of the detection algorithm. RESULTS: Results show that, depending on the severity and location of dyskinesia, specificities and sensitivities higher than 90% are achieved using a leave-one-out methodology. Although mild dyskinesias presented on the limbs are detected with 95% specificity and 39% sensitivity, the most important types of dyskinesia (any strong dyskinesia and trunk mild dyskinesia) are assessed with 95% specificity and 93% sensitivity. CONCLUSION: The presented algorithmic method and wearable device have been successfully validated in monitoring the occurrence of strong dyskinesias and mild trunk dyskinesias during activities of daily living.


Assuntos
Acelerometria/instrumentação , Antiparkinsonianos/uso terapêutico , Discinesias/diagnóstico , Levodopa/uso terapêutico , Doença de Parkinson/tratamento farmacológico , Antiparkinsonianos/efeitos adversos , Discinesias/etiologia , Humanos , Levodopa/efeitos adversos , Monitorização Fisiológica , Doença de Parkinson/complicações , Máquina de Vetores de Suporte
8.
Med Biol Eng Comput ; 54(1): 223-33, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26429349

RESUMO

Freezing of gait (FOG) is a common motor symptom of Parkinson's disease (PD), which presents itself as an inability to initiate or continue gait. This paper presents a method to monitor FOG episodes based only on acceleration measurements obtained from a waist-worn device. Three approximations of this method are tested. Initially, FOG is directly detected by a support vector machine (SVM). Then, classifier's outputs are aggregated over time to determine a confidence value, which is used for the final classification of freezing (i.e., second and third approach). All variations are trained with signals of 15 patients and evaluated with signals from another 5 patients. Using a linear SVM kernel, the third approach provides 98.7% accuracy and a geometric mean of 96.1%. Moreover, it is investigated whether frequency features are enough to reliably detect FOG. Results show that these features allow the method to detect FOG with accuracies above 90% and that frequency features enable a reliable monitoring of FOG by using simply a waist sensor.


Assuntos
Acelerometria/métodos , Marcha , Doença de Parkinson/fisiopatologia , Humanos , Aprendizado de Máquina , Máquina de Vetores de Suporte
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...