Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 19(6): e0305401, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38917142

RESUMO

PURPOSE: The aim of this pilot study was to determine whether viewing an immersive 3D movie with large disparities in a cinema resulted in improved visual acuity (VA), stereoscopic depth perception (ST), and improved eye alignment in residual amblyopic children and children without amblyopia. METHODS: A total of 24 children aged between 5 and 12 years with a history of anisometropic and/or strabismic amblyopia, that had been previously treated and who currently have residual amblyopia (N = 14), and in children with typical development without amblyopia (N = 10) viewed the movie in 3D Sing 2 in a cinema for 110 minutes. Visual acuity, stereoacuity and ocular deviation were assessed before viewing the movie, and three months later. Stereoacuity and ocular deviation were also measured immediately after viewing the movie. RESULTS: We observed an improvement in visual acuity in the non-dominant (amblyopic) eye 3 months after viewing the movie in the amblyopic group (P<0.001). Stereopsis improved immediately after viewing the movie (P = 0.02), and after 3 months by ≈ 40% (P = 0.01). Moreover, improvements in stereopsis were also observed in children without amblyopia (P = 0.04). No significant changes in ocular deviation were observed in either group. CONCLUSIONS: These pilot results suggest that brief exposure to large disparities by viewing a 3D movie in a cinema can help to improve stereopsis and visual acuity in children aged 5‒12 years with previously treated amblyopia, and provide a rationale for a randomized clinical trial.


Assuntos
Ambliopia , Percepção de Profundidade , Filmes Cinematográficos , Acuidade Visual , Humanos , Ambliopia/fisiopatologia , Ambliopia/terapia , Criança , Projetos Piloto , Acuidade Visual/fisiologia , Feminino , Masculino , Pré-Escolar , Percepção de Profundidade/fisiologia
2.
Invest Ophthalmol Vis Sci ; 64(14): 17, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37962529

RESUMO

Purpose: Uncorrected hyperopic children must overcome an apparent conflict between accommodation and vergence demands to focus and align their retinal images. This study tested hypotheses about simultaneous accommodation and vergence performance of young hyperopes to gain insight into ocular motor strategies used to maintain eye alignment. Methods: Simultaneous eccentric photorefraction and Purkinje image tracking were used to assess accommodative and vergence responses of 26 adult emmetropes (AE) and 94 children (0-13 years) viewing cartoons. Children were habitually uncorrected (CU) (spherical equivalent refractive error [SE] -0.5 to +4 D), corrected and aligned (CCA), or corrected with a history of refractive esotropia (CCS). Accommodative and vergence accuracy, dissociated heterophoria, and vergence/accommodation ratios in the absence of retinal disparity cues were measured for 33- and 80-cm viewing distances. Results: In binocular viewing, median accommodative lags for 33 cm were 1.0 D (AE), 1.33 D (CU), 1.25 D (CCA), and 1.0 D (CCS). Median exophorias at 80 and 33 cm were 1.2 and 4.5 pd (AE), 0.8 and 2.5 pd (CU), and 0 and 1.2 pd (CCA), respectively. Without disparity cues, most response vergence/accommodation ratios were between 1 and 2 meter angle/D (∼5-10 pd/D) (69% of AE, 44% of CU, 60% of CCA, and 50% of CCS). Conclusions: Despite apparent conflict in motor coupling, uncorrected hyperopes were typically exophoric and achieved adultlike accuracy of both vergence and accommodation simultaneously, indicating ability to compensate for conflicting demands rather than bias to accurate vergence while tolerating inaccurate accommodation. Large lags and esophoria are therefore atypical. This analysis provides normative guidelines for clinicians and a deeper mechanistic understanding of how hyperopes avoid strabismus.


Assuntos
Esotropia , Exotropia , Hiperopia , Estrabismo , Adulto , Criança , Humanos , Acomodação Ocular , Sinais (Psicologia)
3.
Biomed Opt Express ; 14(8): 3936-3949, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37799689

RESUMO

Eye movement control is impaired in some neurological conditions, but the impact of COVID-19 on eye movements remains unknown. This study aims to investigate differences in oculomotor function and pupil response in individuals who suffer post-COVID-19 condition (PCC) with cognitive deficits. Saccades, smooth pursuit, fixation, vergence and pupillary response were recorded using an eye tracker. Eye movements and pupil response parameters were computed. Data from 16 controls, 38 COVID mild (home recovery) and 19 COVID severe (hospital admission) participants were analyzed. Saccadic latencies were shorter in controls (183 ± 54 ms) than in COVID mild (236 ± 83 ms) and COVID severe (227 ± 42 ms) participants (p = 0.017). Fixation stability was poorer in COVID mild participants (Bivariate Contour Ellipse Area of 0.80 ± 1.61°2 vs 0.36 ± 0.65 °2 for controls, p = 0.019), while percentage of pupil area reduction/enlargement was reduced in COVID severe participants (39.7 ± 12.7%/31.6 ± 12.7% compared to 51.7 ± 22.0%/49.1 ± 20.7% in controls, p < 0.015). The characteristics of oculomotor alterations found in PCC may be useful to understand different pathophysiologic mechanisms.

4.
Biomed Opt Express ; 14(10): 5488-5498, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37854562

RESUMO

Fogging is a non-invasive technique based on the use of positive spherical power lenses to relax accommodation during refraction that is commonly used as an alternative to cycloplegic drugs. Although the mechanism of the fogging technique has been described, some aspects of its methodology remain unclear. The main purpose of this work was to determine which lens power and time of application are more suitable for achieving a successful relaxation of accommodation by analyzing the changes in accommodation when fogging lenses of different powers were placed in front of the participants' eye for a certain timespan. The results of this analysis showed, in general, that low-power lenses and timespans of less than half a minute provided the highest relaxation of accommodation. However, high inter-subject variability was found in the two variables (power and time).

5.
PLoS One ; 18(5): e0284552, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37141181

RESUMO

Two tests to measure fusional vergence amplitudes objectively were developed and validated against the two conventional clinical tests. Forty-nine adults participated in the study. Participants' negative (BI, base in) and positive (BO, base out) fusional vergence amplitudes at near were measured objectively in an haploscopic set-up by recording eye movements with an EyeLink 1000 Plus (SR Research). Stimulus disparity changed in steps or smoothly mimicking a prim bar and a Risley prism, respectively. Break and recovery points were determined offline using a custom Matlab algorithm for the analysis of eye movements. Fusional vergence amplitudes were also measured with two clinical tests using a Risley prism and a prism bar. A better agreement between tests was found for the measurement of BI than for BO fusional vergence amplitudes. The means ± SD of the differences between the BI break and recovery points measured with the two objective tests were -1.74 ± 3.35 PD and -1.97 ± 2.60 PD, respectively, which were comparable to those obtained for the subjective tests. For the BO break and recovery points, although the means of the differences between the two objective tests were small, high variability between subjects was found (0.31 ± 6.44 PD and -2.84 ± 7.01 PD, respectively). This study showed the feasibility to measure fusional vergence amplitudes objectively and overcome limitations of the conventional subjective tests. However, these tests cannot be used interchangeably due to their poor agreement.


Assuntos
Convergência Ocular , Ligustrum , Adulto , Humanos , Estudos de Viabilidade , Visão Binocular , Cultura
6.
Ophthalmic Physiol Opt ; 43(4): 598-614, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36692334

RESUMO

PURPOSE: Individuals with different types of intermittent exotropia (IXT) may use neurally coupled accommodation and vergence responses differently from those without exotropia to achieve eye alignment. This study examined the relationship between simultaneously recorded accommodation and vergence responses in children and young adults with a range of types of IXT while aligned and deviated. METHODS: Responses of 29 participants with IXT (4-31 years) and 24 age-matched controls were recorded using simultaneous eye-tracking and eccentric photorefraction while they watched a movie in binocular or monocular viewing at varying viewing distances. Gradient response AC/A ratios and fusional vergence ranges were also assessed. Eight participants had divergence or pseudo-divergence excess type IXT, 5 had convergence insufficiency and 16 had basic IXT. RESULTS: Control and IXT participants accommodated similarly both in monocular and binocular-aligned conditions to visual targets at 80 and 33 cm. When deviated in binocular viewing, most participants with IXT exhibited changes in accommodation <0.5D relative to alignment. Gradient response AC/A ratios were similar for control [0.56 MA/D (IQR: 0.51 MA/D)] and IXT participants [0.42 MA/D (0.54 MA/D); p  = 0.60]. IXT participants showed larger vergence to accommodation ratios with changes from distance to near fixation [1.19 MA/D (1.45 MA/D)] than control participants [0.78 MA/D (0.60 MA/D); p = 0.02], especially among IXT participants with divergence or pseudo-divergence excess. Participants with IXT exhibited typical fusional divergence ranges beyond their dissociated position [8.86 Δ (7.10 Δ)] and typical fusional convergence ranges from alignment [18 Δ (15.75 Δ)]. CONCLUSIONS: This study suggests that control of IXT is typically neither driven by accommodative convergence alone nor associated with over-accommodation secondary to fusional convergence efforts. These simultaneous measurements confirmed that proximal vergence contributed significantly to IXT control, particularly for divergence or pseudo-divergence excess type IXT. For IXT participants in this study, achieving eye alignment did not conflict with having clear vision.


Assuntos
Exotropia , Estrabismo , Criança , Adulto Jovem , Humanos , Visão Binocular/fisiologia , Convergência Ocular , Acomodação Ocular , Doença Crônica
7.
Biomed Opt Express ; 13(6): 3504-3519, 2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35781951

RESUMO

We examined the spectral reflectance of fundus structures in the visible and near-infrared (400-1300 nm) range for contributing to the medical diagnosis of fundus diseases. Spectral images of healthy eye fundus and other ocular diseases were acquired using a novel multispectral fundus camera. Reflectance metrics were computed based on contrast to analyze the spectral features. Significant differences were observed among the structures in healthy and diseased eye fundus. Specifically, near-infrared analysis allows imaging of deeper layers, such as the choroid, which, to date, has not been retrieved using traditional color fundus cameras. Pathological structures, which were hardly observable in color fundus images owing to metamerism, were also revealed by the developed multispectral fundus camera.

8.
Vision Res ; 187: 27-40, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34147850

RESUMO

The near point of convergence test is widely used to evaluate binocular vision. It assesses the ability of the eyes to converge at short distances. Although the test consists of a pure symmetrical vergence task, small involuntary saccades occur concurrently. The main goal of this study was to analyze saccadic characteristics as a function of vergence demand when testing the near point of convergence. To this purpose, the eye movements of 11 participants were registered with an eye-tracker while they performed the near point of convergence test by following a target that traveled forward and backward on a motorized bench. Saccade amplitude increased and, on average, saccade rate decreased with vergence demand. In general, the direction of the concurrent vergence movement had no significant effect on saccade characteristics. However, each individual subject showed idiosyncratic behavior. Most saccades tended to be corrective in terms of both binocular disparity and individual fixation position errors. In particular, most participants tended to correct the fixation position error of the dominant eye.


Assuntos
Convergência Ocular , Movimentos Sacádicos , Humanos , Motivação , Disparidade Visual , Visão Binocular
9.
PLoS One ; 13(11): e0206674, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30383846

RESUMO

Heterophoria is the relative deviation of the eyes in absence of fusional vergence. Fusional vergence can be deprived by, for example, occluding one eye while the other fixates a visual target. Then, the occluded eye will presumably deviate from its initial position by an amount that corresponds to the heterophoria. Its assessment in clinical practice is crucial for the diagnosis of non-strabismic binocular dysfunctions such as convergence insufficiency. Traditional clinical methods, like the cover test or the modified Thorington test, suffer from practitioner's subjectivity, impossibility to observe the occluding eye or unusual viewing conditions. These limitations could be overcome by using eye tracking systems to measure objectively the heterophoria. The main purpose of this study was to compare the performance of an automated and objective method to measure near heterophoria using an eye-tracker with two conventional methods: the cover-uncover test and the modified Thorington test. The eye tracking method gave us the possibility to measure the heterophoria as the deviation of the occluded eye (mimicking the cover test) or as the deviations of the occluded and fixating eyes (adhering to the theoretical definition of heterophoria). The latter method provided smaller results than the former, although on average the differences might not be clinically relevant. The proposed objective method exhibited considerably better repeatability than the two conventional clinical methods. It showed better agreement with the modified Thorington test than with the cover-uncover test, and a similar level of agreement was obtained between the two clinical methods. To conclude, the use of eye-trackers to measure heterophoria provides objective and more repeatable measures. As eye-trackers become common tools in clinical settings, their use to measure heterophoria should be the new gold standard.


Assuntos
Automação , Medições dos Movimentos Oculares , Estrabismo/diagnóstico , Adulto , Desenho de Equipamento , Feminino , Fixação Ocular , Humanos , Masculino , Estimulação Luminosa , Reprodutibilidade dos Testes , Adulto Jovem
10.
J Biomed Opt ; 23(3): 1-9, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29500875

RESUMO

A set of methods in terms of both image processing and gaze estimation for accurate eye tracking is proposed. The eye-tracker used in this study relies on the dark-pupil method with up to 12 corneal reflections and offers an unprecedented high resolution imaging of the pupil and the cornea. The potential benefits of a higher number of glints and their optimum arrangement are analyzed considering distinct light sources configurations with 12, 8, 6, 4, and 2 corneal reflections. Moreover, a normalization factor of the pupil-glint vector is proposed for each configuration. There is a tendency for increasing accuracy with the number of glints, especially vertically (0.47 deg for 12 glints configuration versus 0.65 deg for 2 glints configuration). Besides the number of corneal reflections, their arrangement seems to have a stronger effect. A configuration that minimizes the interference of the eyelids with the corneal reflections is desired. Finally, the normalization of the pupil-glint vectors improves the vertical eye tracking accuracy up to 43.2%. In addition, the normalization also limits the need for a higher number of light sources to achieve better spatial accuracy.


Assuntos
Córnea/diagnóstico por imagem , Técnicas de Diagnóstico Oftalmológico , Movimentos Oculares/fisiologia , Processamento de Imagem Assistida por Computador/métodos , Adulto , Desenho de Equipamento , Fixação Ocular/fisiologia , Humanos , Pupila/fisiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...