Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Br J Anaesth ; 117(5): 610-616, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27799175

RESUMO

BACKGROUND: Several guidelines have been published to facilitate implementation of patient blood management (PBM). This study was performed to evaluate clinical practices in PBM. METHODS: An online survey based on the guidelines for the management of severe perioperative bleeding from the European Society of Anaesthesiology (ESA) was conducted among ESA members. We assessed characteristic data of participating physicians, preoperative assessment of bleeding risk and anaemia, intraoperative transfusion practices, specific pharmacologic treatment of significant bleeding, and clinical use of PBM algorithms. Data distributions for five European regions and the workplace and experience of physicians were analysed using a χ2 test. RESULTS: We received 706 fully completed surveys from physicians in 57 countries. Most (99%) respondents were anaesthetists or intensive care physicians, and 68% worked at university or university-affiliated hospitals. A standardised bleeding history before surgery is routinely obtained by 48% of physicians. When bleeding history is negative, 55% of physicians routinely order preoperative coagulation testing. Only 24% of physicians timely assess patients at risk of bleeding during surgery for anaemia before elective surgery. When anaemia is diagnosed, 38% of physicians routinely investigate its cause. The rate of routinely performed targeted haemostatic interventions with fibrinogen, vitamin K or prothrombin complex, and tranexamic acid was 60%, 52%, and 54%, respectively. Algorithms to guide PBM are used by 62% of physicians. Results varied between geographic regions. CONCLUSIONS: Major deficits exist in the use of recommended PBM among anaesthetists, indicating an opportunity to improve clinical standards.


Assuntos
Perda Sanguínea Cirúrgica/prevenção & controle , Transfusão de Sangue/estatística & dados numéricos , Pesquisas sobre Atenção à Saúde/estatística & dados numéricos , Hemostáticos/uso terapêutico , Assistência Perioperatória/métodos , Padrões de Prática Médica/estatística & dados numéricos , Europa (Continente) , Hemostasia , Humanos
2.
Intensive Care Med ; 38(10): 1647-53, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22777516

RESUMO

PURPOSE: To quantify the numbers of critical care beds in Europe and to understand the differences in these numbers between countries when corrected for population size and gross domestic product. METHODS: Prospective data collection of critical care bed numbers for each country in Europe from July 2010 to July 2011. Sources were identified in each country that could provide data on numbers of critical care beds (intensive care and intermediate care). These data were then cross-referenced with data from international databases describing population size and age, gross domestic product (GDP), expenditure on healthcare and numbers of acute care beds. RESULTS: We identified 2,068,892 acute care beds and 73,585 (2.8 %) critical care beds. Due to the heterogeneous descriptions of these beds in the individual countries it was not possible to discriminate between intensive care and intermediate care in most cases. On average there were 11.5 critical care beds per 100,000 head of population, with marked differences between countries (Germany 29.2, Portugal 4.2). The numbers of critical care beds per country corrected for population size were positively correlated with GDP (r(2) = 0.16, p = 0.05), numbers of acute care beds corrected for population (r(2) = 0.12, p = 0.05) and the percentage of acute care beds designated as critical care (r(2) = 0.59, p < 0.0001). They were not correlated with the proportion of GDP expended on healthcare. CONCLUSIONS: Critical care bed numbers vary considerably between countries in Europe. Better understanding of these numbers should facilitate improved planning for critical care capacity and utilization in the future.


Assuntos
Ocupação de Leitos/estatística & dados numéricos , Cuidados Críticos/estatística & dados numéricos , Número de Leitos em Hospital/estatística & dados numéricos , Unidades de Terapia Intensiva/estatística & dados numéricos , Instituições para Cuidados Intermediários/estatística & dados numéricos , Adulto , Europa (Continente) , Humanos , Unidades de Terapia Intensiva/provisão & distribuição , Instituições para Cuidados Intermediários/provisão & distribuição , Estudos Prospectivos
3.
Br J Anaesth ; 109(3): 376-81, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22719014

RESUMO

BACKGROUND: Surgical excision of burn wounds is often associated with severe bleeding. Timely and targeted correction of coagulopathy reduces transfusion requirements and improves survival in trauma victims. We hypothesized that rapid correction of coagulopathy after a treatment algorithm based on point-of-care viscoelastic coagulation testing would decrease allogeneic blood product transfusions during surgical excision of burn wounds. METHODS: Thirty consecutive patients undergoing surgical excision of burn wounds were enrolled into this prospective, randomized, controlled, single-centre study. In the control group, coagulation management was performed according to the clinicians' discretion. For the algorithm group, we standardized treatment based on the Austrian recommendation for the management of trauma-induced coagulopathy using point-of-care rotational thromboelastometry (ROTEM(®)). The main outcome parameter was the cumulative number of allogeneic blood units transfused on the day of surgery. RESULTS: The difference between the groups regarding the cumulative use of allogeneic blood products was highly significant with 3.0 (1.3-5.5) blood products in the algorithm group compared with 9.0 (6.0-12.3) in the control group [median (inter-quartile range); P=0.002]. No plasma was administered in the algorithm group compared with 5.0 (1.5-7.5) units overall in the control group (P<0.001). Fibrinogen concentrate administration was not significantly different between the groups (P=0.89). Tranexamic acid was not administered. CONCLUSIONS: The significant reduction in allogeneic blood product requirements during surgical burn wound excision is a prospective proof of concept that a bleeding management algorithm based on thromboelastometry is efficacious. Hypofibrinogenaemia and hyperfibrinolysis are not significant pathomechanisms of bleeding in this setting and ROTEM(®) helps to avoid unnecessary interventions.


Assuntos
Transfusão de Sangue , Queimaduras/cirurgia , Hemorragia/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Feminino , Fibrinogênio/uso terapêutico , Humanos , Masculino , Pessoa de Meia-Idade , Tempo de Tromboplastina Parcial , Sistemas Automatizados de Assistência Junto ao Leito , Estudos Prospectivos , Tromboelastografia
4.
Intensive Care Med ; 38(6): 984-90, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22446990

RESUMO

PURPOSE: Venous thromboembolism (VTE) is a common but often overlooked life-threatening complication of critical illness. The aim of this cross-sectional survey was to assess current practice of thromboprophylaxis as well as adherence to international guidelines. METHODS: After ethics committee approval, all intensive care units in Austrian hospitals treating adult patients were invited to participate in this web-based survey. Anonymized data on each patient treated at the participating intensive care units on Coagulation Day 2010 were collected using an electronic case report form. Risk assessment, choice and monitoring of anticoagulants, means of mechanical prophylaxis, and demographic data were recorded. RESULTS: Data from 325 critically ill patients were collected. Patients had a median of four risk factors for thrombosis and 6 % suffered from VTE. Of the 325 patients, 80 % received low molecular weight heparins subcutaneously, 10 % received unfractionated heparin intravenously, 1 % received alternative anticoagulants and 9 % received no pharmacological prophylaxis. Mechanical prophylaxis was used in 49 % with a predominant use of graduated compression stockings. In 39 % a combination of pharmacological and mechanical prophylaxis was applied and 5 % received no prophylaxis at all. Overall guideline adherence was 40 % on Coagulation Day 2010. CONCLUSION: Current practice of thromboprophylaxis is predominantly based on the administration of low molecular weight heparins prescribed at rather arbitrary doses without a discernible relationship to drug monitoring, thromboembolic risk factors, vasopressor use or fluid balance. The use of mechanical prophylaxis, evaluation of risk scores and overall guideline adherence must be further encouraged by education, training and communication.


Assuntos
Unidades de Terapia Intensiva , Tromboembolia/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Áustria , Feminino , Pesquisas sobre Atenção à Saúde , Heparina de Baixo Peso Molecular/uso terapêutico , Humanos , Masculino , Pessoa de Meia-Idade , Padrões de Prática Médica/estatística & dados numéricos , Fatores de Risco , Meias de Compressão , Inquéritos e Questionários , Tromboembolia/etiologia
5.
Intensive Care Med ; 38(4): 598-605, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22278594

RESUMO

OBJECTIVES: To define a set of indicators that could be used to improve quality in intensive care medicine. METHODOLOGY: An European Society of Intensive Care Medicine Task Force on Quality and Safety identified all commonly used key quality indicators. This international Task Force consisted of 18 experts, all with a self-proclaimed interest in the area. Through a modified Delphi process seeking greater than 90% consensual agreement from this nominal group, the indicators were then refined through a series of iterative processes. RESULTS: A total of 111 indicators of quality were initially found, and these were consolidated into 102 separate items. After five discrete rounds of debate, these indicators were reduced to a subset of nine that all had greater than 90% agreement from the nominal group. These indicators can be used to describe the structures (3), processes (2) and outcomes (4) of intensive care. Across this international group, it was much more difficult to obtain consensual agreement on the indicators describing processes of care than on the structures and outcomes. CONCLUSION: This document contains nine indicators, all of which have a high level of consensual agreement from an international Task Force, which could be used to improve quality in routine intensive care practice.


Assuntos
Cuidados Críticos/normas , Estado Terminal , Segurança do Paciente , Melhoria de Qualidade , Indicadores de Qualidade em Assistência à Saúde , Comitês Consultivos , Técnica Delphi , Europa (Continente) , Humanos , Estudos Prospectivos
6.
Intensive Care Med ; 27(6): 992-8, 2001 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-11497158

RESUMO

OBJECTIVES: To evaluate the performance of the logistic organ dysfunction (LOD) system for the assessment of morbidity and mortality in multiple organ dysfunction/failure (MOD/F) in an independent database and to evaluate the use of sequential LOD measurements for the prediction of outcome. DESIGN AND SETTING: Prospective, multicentric cohort study in 13 adult medical, surgical, and mixed intensive care units (ICUs) in Austria. PATIENTS: A total of 2,893 consecutive admissions to the ICUs. MEASUREMENTS AND MAIN RESULTS: Patient vital status at ICU and hospital discharge was recorded. Univariate analysis showed that the LOD was able to distinguish between survivors and nonsurvivors (2 vs. 6 median score). Within organ systems, higher levels of the severity of organ dysfunction were consistently associated with higher mortality. For the prediction of hospital mortality, the original prognostic LOD model did not perform well in our patients, as indicated by the goodness-of-fit C statistic. Using multiple logistic regression we developed a prognostic model with a satisfactory fit in our patients. The integration of further measurements during the ICU stay increased discrimination but not calibration. CONCLUSIONS: The LOD system is well correlated well with the numbers and levels of organ dysfunctions and discriminates well between survivors and nonsurvivors. It can thus be used to quantify the baseline severity of organ dysfunction. Moreover, after customization of the predictive equation the LOD predicted hospital mortality in our patients with high precision. It thus provides a combined measure of morbidity and mortality for critically ill patients with MOD/F.


Assuntos
Mortalidade Hospitalar , Insuficiência de Múltiplos Órgãos/mortalidade , Idoso , Áustria , Bases de Dados Factuais , Humanos , Unidades de Terapia Intensiva , Tempo de Internação , Modelos Logísticos , Pessoa de Meia-Idade , Insuficiência de Múltiplos Órgãos/classificação , Índice de Gravidade de Doença
8.
Intensive Care Med ; 26(10): 1466-72, 2000 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11126258

RESUMO

OBJECTIVES: To validate SAPS II-AM, a recently customized version of the Simplified Acute Physiology Score II (SAPS II) in a larger cohort of Austrian intensive care patients and to evaluate the effect of the customization process on the ratio of observed to expected mortality. DESIGN: Prospective, multicentric cohort study. PATIENTS AND SETTING: A total of 2,901 patients consecutively admitted to 13 adult medical, surgical, and mixed intensive care units (ICUs) in Austria. MEASUREMENTS AND RESULTS: After the database was divided randomly into a development sample (n = 1,450) and a validation sample (n = 1,451), logistic regression was used to develop a new model (SAPS II-AM2). The original SAPS II, the SAPS IIAM, and the newly developed SAPS II-AM2 were then compared by means of calibration, discrimination and O/E ratios. Differences in O/E ratios before and after customization (deltaO/E) were calculated. The Hosmer-Lemeshow goodness-of-fit H and C statistics revealed poor calibration of the original SAPS II on the database. The new model, SAPS II-AM2, performed better than the SAPS II-AM and excellent in the validation data set. However, mean O/E ratios varied widely among diagnostic categories (range 0.55-1.05 for the SAPS II). Moreover, the deltaO/E of the 13 ICUs ranged from -3.6 % to +25 %. CONCLUSIONS: Today's severity scoring systems, such as the SAPS II, are limited by not measuring (and adjusting for) a profound part of what constitutes case mix. Changes in the distribution of patient characteristics (known and unknown) therefore affect prognostic accuracy. First-level customization was not able to solve all these problems. Using O/E ratios for quality of care comparisons one must therefore be critical when using these data and should search for possible confounding factors. In the case of unsatisfactory calibration, customized severity of illness models may be useful as an adjunct for quality control.


Assuntos
APACHE , Grupos Diagnósticos Relacionados/estatística & dados numéricos , Mortalidade Hospitalar , Unidades de Terapia Intensiva/normas , Qualidade da Assistência à Saúde , Idoso , Áustria , Calibragem , Análise Discriminante , Humanos , Unidades de Terapia Intensiva/estatística & dados numéricos , Modelos Logísticos , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos
9.
Transplantation ; 69(11): 2394-400, 2000 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-10868647

RESUMO

BACKGROUND: Impaired pulmonary function is a frequent finding in patients undergoing orthotopic liver transplantation (OLT). Experimental data suggest an essential contribution of splanchnic ischemia and reperfusion as a result of intraoperative volume shifts, i.e., the accumulation of extravascular lung water (EVLW). Increases of intrathoracic blood volume (ITBV) and pulmonary blood volume (PBV) might additionally influence pulmonary capillary fluid filtration. The main objective of this study was to determine the intrathoracic volume changes during OLT and to test whether there were any relationships between intra- and extravascular volume shifts and pulmonary function, as determined by the calculation of venous admixture (QS/QT) and alveolar-arterial oxygen gradient (AaDO2). METHODS: Twenty-five patients undergoing OLT were studied. Using the transpulmonary double indicator dilution method, ITBV, PBV, and EVLW were determined from the mean transit times and exponential decay times of the indocyanine green and the thermal indicator curves recorded simultaneously with a fiberoptic catheter in the descending aorta. Recordings were made after induction of anesthesia, at the end of the anhepatic stage, immediately after reperfusion, and 1 and 4 h postoperatively. RESULTS: Significant increases in QS/QT related to changes of ITBV were observed after reperfusion. Only a minor impact on AaDO2 was perceived. EVLW remained constant during the study period. CONCLUSIONS: Postreperfusion increases of ITBV influence pulmonary function, as demonstrated by the increase in QS/QT. However, they need not be associated with greater EVLW levels, and impact on oxygenation is less severe than assumed. Hence, sufficient mechanisms protecting oxygenation and stalling increased EVLW seem to be present during uncomplicated human OLT.


Assuntos
Líquidos Corporais/metabolismo , Transplante de Fígado , Pulmão/fisiopatologia , Tórax/metabolismo , Adulto , Idoso , Volume Sanguíneo , Feminino , Hemodinâmica , Humanos , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Troca Gasosa Pulmonar , Tórax/irrigação sanguínea
11.
Crit Care Med ; 27(8): 1486-91, 1999 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10470754

RESUMO

OBJECTIVES: To evaluate the ability of an interdisciplinary data set (recently defined by the Austrian Working Group for the Standardization of a Documentation System for Intensive Care [ASDI]) to assess intensive care units (ICUs) by means of the Simplified Acute Physiology Score II (SAPS II) for the severity of illness and the simplified Therapeutic Intervention Scoring System (TISS-28) for the level of provided care. DESIGN: A prospective, multicentric study. SETTING: Nine adult medical, surgical, and mixed ICUs in Austria. PATIENTS: A total of 1234 patients consecutively admitted to the ICUs. INTERVENTIONS: Collection of data for the ASDI data set. MEASUREMENTS AND MAIN RESULTS: The overall mean SAPS II score was 33.1+/-2.1 points. SAPS II overestimated hospital mortality by predicting mortality of 22.2%+/-2.9%, whereas observed mortality was only 16.8%+/-2.2%. The Hosmer-Lemeshow goodness-of-fit test for SAPS II scores showed lacking uniformity of fit (H = 53.78, 8 degrees of freedom; p < .0001). TISS-28 scores were recorded on 8616 days (30.6+/-1.5 points). TISS-28 scores were higher in nonsurvivors than in survivors (30.4+/-0.9 vs. 25.7+/-0.4, respectively; p < .05). No significant correlation between mean TISS-28 per patient per unit on the day of admission and mean predicted hospital mortality (r2 = .23; p < .54) or standardized mortality ratio per unit (r2 = -.22; p < .56) was found. CONCLUSIONS: Implementation of an interdisciplinary data set for ICUs provided data with which to evaluate performance in terms of severity of illness and provided care. The SAPS II did not accurately predict outcomes in Austrian ICUs and must, therefore, be customized for this population. A combination of indicators for both severity of illness and amount of provided care is necessary to evaluate ICU performance. Further data acquisition is needed to customize the SAPS II and to validate the TISS-28.


Assuntos
APACHE , Documentação/normas , Mortalidade Hospitalar , Unidades de Terapia Intensiva/normas , Avaliação de Resultados em Cuidados de Saúde/organização & administração , Equipe de Assistência ao Paciente , Adulto , Áustria , Humanos , Tempo de Internação/estatística & dados numéricos , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Respiração Artificial/estatística & dados numéricos , Sensibilidade e Especificidade , Análise de Sobrevida
12.
Acta Anaesthesiol Scand ; 43(5): 515-9, 1999 May.
Artigo em Inglês | MEDLINE | ID: mdl-10341998

RESUMO

BACKGROUND: Mechanical hyperventilation is an established treatment to reduce brain edema and intracranial pressure in patients with encephalopathia caused by acute liver failure. Hyperventilation and ensuing hypocarbia may also affect central and systemic circulation and thereby influence graft performance in patients following orthotopic liver transplantation (OLT). METHODS: We measured the effects of normocapnia and hypocapnia on systemic hemodynamics, gastric tonometry, as a marker of splanchnic oxygenation, and the indocyanine green kinetic, as a global marker of graft function, in humans post OLT. RESULTS: Hyperventilation was performed to a PaCO2 of 4.2 +/- 0.4 kPa (31 +/- 3.4 mm Hg) for about 1 h in 14 liver transplant recipients. Systemic hemodynamics as well as indices of splanchnic oxygenation and indocyanine green kinetics remained statistically unchanged. CONCLUSION: We did not observe any statistically significant circulatory effects or changes in indocyanine green kinetics in liver transplant recipients in the immediate OLT postoperative period caused by short-term mechanical hyperventilation.


Assuntos
Transplante de Fígado/fisiologia , Respiração Artificial/métodos , Circulação Esplâncnica/fisiologia , Pressão Sanguínea/fisiologia , Edema Encefálico/prevenção & controle , Dióxido de Carbono/sangue , Pressão Venosa Central/fisiologia , Corantes , Feminino , Mucosa Gástrica/fisiopatologia , Encefalopatia Hepática/fisiopatologia , Encefalopatia Hepática/cirurgia , Humanos , Concentração de Íons de Hidrogênio , Hiperventilação/fisiopatologia , Hipocapnia/fisiopatologia , Verde de Indocianina , Pressão Intracraniana/fisiologia , Falência Hepática Aguda/fisiopatologia , Falência Hepática Aguda/cirurgia , Masculino , Pessoa de Meia-Idade , Oxigênio/sangue , Consumo de Oxigênio/fisiologia , Pressão Propulsora Pulmonar/fisiologia
13.
Intensive Care Med ; 25(2): 180-5, 1999 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-10193545

RESUMO

OBJECTIVES: Reactive oxygen species (ROS) have been implicated in the pathophysiology of ARDS. We investigated the pattern of antioxidants in plasma and ROS production by neutrophils in patients with ARDS over 6 days. DESIGN: Observational study. Blood samples were taken when the diagnosis was made (D0) and after 3 (D3) and 6 days (D6) during therapy. SETTING: Intensive care units at a University Hospital. PATIENTS: Eight patients with ARDS were investigated, 17 healthy volunteers served as controls. MEASUREMENTS AND RESULTS: Plasma levels of ascorbate, alpha-tocopherol, retinol, beta-carotene, selenium and lipid peroxidation products (MDA) were determined and the activities of the antioxidative enzymes catalase (CAT), superoxide dismutase (SOD) and glutathione-peroxidase (GSH-PX) in erythrocytes were measured. In addition, ROS production (superoxide anion and hydrogen peroxide) in activated neutrophils was assessed. Plasma levels of alpha-tocopherol, ascorbate, beta-carotene and selenium were reduced from the onset of illness. MDA plasma levels were increased throughout the illness. ROS generation from neutrophils was normal on D0 and decreased to D6 in ARDS patients. CONCLUSION: The antioxidative system is severely compromised in patients with ARDS. Plasma levels of alpha-tocopherol, ascorbate, beta-carotene and selenium are decreased. Elevated MDA levels provide further evidence of massive oxidative stress. The routine replacement of micronutrients according to recommended daily allowances was inadequate to compensate for the increased requirements.


Assuntos
Antioxidantes/metabolismo , Espécies Reativas de Oxigênio/metabolismo , Síndrome do Desconforto Respiratório/metabolismo , Adulto , Criança , Cromatografia Líquida de Alta Pressão , Feminino , Glutationa Peroxidase/sangue , Humanos , Unidades de Terapia Intensiva , Peroxidação de Lipídeos , Masculino , Micronutrientes , Pessoa de Meia-Idade , Neutrófilos/metabolismo , Política Nutricional , Nutrição Parenteral , Síndrome do Desconforto Respiratório/sangue , Síndrome do Desconforto Respiratório/classificação , Síndrome do Desconforto Respiratório/enzimologia , Índice de Gravidade de Doença , Superóxido Dismutase/sangue , Vitaminas/sangue
14.
Intensive Care Med ; 25(2): 192-7, 1999 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-10193547

RESUMO

OBJECTIVES: To evaluate the prognostic performance of the original Simplified Acute Physiology Score (SAPS) II in Austrian intensive care patients and to evaluate the impact of customization. DESIGN: Analysis of the database of a multicenter study. SETTING: Nine adult medical, surgical, and mixed intensive care units (ICUs) in Austria. PATIENTS: A total of 1733 patients consecutively admitted to the ICUs. MEASUREMENTS AND RESULTS: The database included admission data, SAPS II, length of stay, and hospital mortality. The Hosmer-Lemeshow goodness-of-fit test for the SAPS II showed a lack of uniformity of fit (H = 89.1, 10 df, p < 0.0001; C = 91.8, 10 df, p < 0.0001). Subgroup analysis showed good performance in patients with cardiovascular (medical and surgical) diseases as the primary reasons for admission. A new predictive equation was derived by means of the logistic regression. Goodness-of-fit was excellent for the customized model (SAPS IIAM) (H = 11.2, 9 df, p = 0.33, C = 11.6, 9 df, p = 0.24). The mean standardized mortality ratio (SMR) changed from 0.81 +/- 0.26 to 0.93 +/- 0.29 with customization. CONCLUSIONS: SAPS II was not well calibrated when applied to all patients. However, it performed well for patients with cardiovascular diseases as the primary reason for admission and may thus be applied to these patients. Standardized mortality ratios that are calculated from scoring systems without known calibration must be viewed with skepticism.


Assuntos
Mortalidade Hospitalar , Unidades de Terapia Intensiva/estatística & dados numéricos , Modelos Estatísticos , Índice de Gravidade de Doença , Áustria , Humanos , Tempo de Internação , Modelos Logísticos , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Probabilidade , Prognóstico
16.
Wien Klin Wochenschr ; 109(4): 132-8, 1997 Feb 28.
Artigo em Alemão | MEDLINE | ID: mdl-9157723

RESUMO

OBJECTIVES: A comparison of data from different intensive care units (ICUs) needs standardized documentation. In this study the ASDI documentation standard for intensive care was tested in clinical practice. Goal of the study was to evaluate parameters and functionality required for a national, interdisciplinary documentation system for intensive care. DESIGN: 13 ICUs participated in a 4-week trial using the provided program for documentation of all admitted patients during the observation period. In addition, a questionnaire was distributed to the unit coordinators. RESULTS: 376 patients were documented in 1591 patient days. Valid SAPS II scores were found in only 29% of the discharged patients (39.1 +/- 15.5 points). Time needed for data entry exceeded preset limits (ten minutes per patient and day) in 38% of the cases. All participants affirmed the necessity of a documentation standard for intensive care, giving quality control and cost analysis as the most important reasons. CONCLUSION: The ASDI data set fitted existing needs very closely. Only 7 out of 122 parameters (5.7%) were found to be superfluous and thus removed. Measures to reduce documentation effort to the default limits were a) a new, date orientated concept for manual recording, b) rede-sign of the user interface with new, user friendly data entry possibilities, and c) the integration of statistical analysis and reports in the documentation system. The revised data set represents a broad-based consensus, which seems to be well-suited as foundation for the national quality assurance program.


Assuntos
Cuidados Críticos/economia , Documentação/normas , Garantia da Qualidade dos Cuidados de Saúde/economia , Software , Adolescente , Adulto , Idoso , Áustria , Criança , Pré-Escolar , Análise Custo-Benefício , Sistemas de Gerenciamento de Base de Dados/economia , Sistemas de Gerenciamento de Base de Dados/normas , Documentação/economia , Feminino , Mortalidade Hospitalar , Humanos , Lactente , Masculino , Sistemas Computadorizados de Registros Médicos/economia , Sistemas Computadorizados de Registros Médicos/normas , Pessoa de Meia-Idade , Projetos Piloto , Software/economia , Software/normas
20.
Intensive Care Med ; 21(9): 703-15, 1995 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-8847425

RESUMO

OBJECTIVE: Computerized Patient Data Management Systems (PDMS) have been developed for handling the enormous increase in data collection in ICUs. This study tries to evaluate the functionality of such systems installed in Europe. DESIGN: Criteria reflecting usefulness and practicality formed the basis of a questionnaire to be answered accurately by the vendors. We then examined functions provided and their implementation in European ICUs. Next, an "Information Delivery Test" evaluated variations in performance, taking questions arising from daily routine work and measured time of information delivery. SETTING: ICUs located in Vienna (Austria), Antwerp (Belgium), Dortmund (Germany), Kuopio (Finland). PARTICIPANTS: 5 PDMS were selected on the basis of our inclusion criteria: commercial availability with at least one installation in Europe, bedside-based design, realization of international standards and a prescribed minimum of functionality. RESULTS: The "Table of Functions" shows an overview of functions and their implementation. "System analyses" indicates predominant differences in properties and functions found between the systems. Results of the "Information Delivery Tests" are shown in the graphic charts. CONCLUSIONS: Systems with graphical data presentation have advantages over systems presenting data mainly in numerical format. Time has come to form a medical establishment powerful enough to set standards and thus communicate with industrial partners as well as with hospital management responsible for planning, purchasing and implementing PDMS. Overall, communication between clinicians, nurses, computer scientists and PDMS vendors must be enhanced to achieve the common goal: useful and practical data management systems at ICUs.


Assuntos
Sistemas de Gerenciamento de Base de Dados/organização & administração , Unidades de Terapia Intensiva , Sistemas Automatizados de Assistência Junto ao Leito/organização & administração , Sistemas de Gerenciamento de Base de Dados/provisão & distribuição , Europa (Continente) , Estudos de Avaliação como Assunto , Humanos , Validação de Programas de Computador , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA