Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(16)2023 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-37631647

RESUMO

BACKGROUND: Cardiovascular diseases (CVDs), being the culprit for one-third of deaths globally, constitute a challenge for biomedical instrumentation development, especially for early disease detection. Pulsating arterial blood flow, providing access to cardiac-related parameters, involves the whole body. Unobtrusive and continuous acquisition of electrical bioimpedance (EBI) and photoplethysmography (PPG) constitute important techniques for monitoring the peripheral arteries, requiring novel approaches and clever means. METHODS: In this work, five peripheral arteries were selected for EBI and PPG signal acquisition. The acquisition sites were evaluated based on the signal morphological parameters. A small-data-based deep learning model, which increases the data by dividing them into cardiac periods, was proposed to evaluate the continuity of the signals. RESULTS: The highest sensitivity of EBI was gained for the carotid artery (0.86%), three times higher than that for the next best, the posterior tibial artery (0.27%). The excitation signal parameters affect the measured EBI, confirming the suitability of classical 100 kHz frequency (average probability of 52.35%). The continuity evaluation of the EBI signals confirmed the advantage of the carotid artery (59.4%), while the posterior tibial artery (49.26%) surpasses the radial artery (48.17%). The PPG signal, conversely, commends the location of the posterior tibial artery (97.87%). CONCLUSIONS: The peripheral arteries are highly suitable for non-invasive EBI and PPG signal acquisition. The posterior tibial artery constitutes a candidate for the joint acquisition of EBI and PPG signals in sensor-fusion-based wearable devices-an important finding of this research.


Assuntos
Doenças Cardiovasculares , Dispositivos Eletrônicos Vestíveis , Humanos , Fotopletismografia , Artéria Radial , Eletricidade
2.
Sensors (Basel) ; 23(9)2023 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-37177455

RESUMO

BACKGROUND: Pelotherapy is the traditional procedure of applying curative muds on the skin's surface-shown to have a positive effect on the human body and cure illnesses. The effect of pelotherapy is complex, functioning through several mechanisms, and depends on the skin's functional condition. The current research objective was to develop a methodology and electrodes to assess the passage of the chemical and biologically active compounds of curative mud through human skin by performing electrical bioimpedance (EBI) analysis. METHODS: The methodology included local area mud pack and simultaneous tap water compress application on the forearms with the comparison to the measurements of the dry skin. A custom-designed small-area gold-plated electrode on a rigid printed circuit board, in a tetrapolar configuration, was designed. A pilot study experiment with ten volunteers was performed. RESULTS: Our results indicated the presence of an effect of pelotherapy, manifested by the varying electrical properties of the skin. Distinguishable difference in the measured real part of impedance (R) emerged, showing a very strong correlation between the dry and tap-water-treated skin (r = 0.941), while a poor correlation between the dry and mud-pack-treated skin (r = 0.166) appeared. The findings emerged exclusively in the frequency interval of 10 kHz …1 MHz and only for R. CONCLUSIONS: EBI provides a promising tool for monitoring the variations in the electrical properties of the skin, including the skin barrier. We foresee developing smart devices for promoting the exploitation of spa therapies.


Assuntos
Peloterapia , Humanos , Projetos Piloto , Pele , Eletrodos , Impedância Elétrica
3.
Sensors (Basel) ; 22(23)2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36502052

RESUMO

BACKGROUND: Wearable technologies for monitoring cardiovascular parameters, including electrocardiography (ECG) and impedance cardiography (ICG), propose a challenging research subject. The expectancy for wearable devices to be unobtrusive and miniaturized sets a goal to develop smarter devices and better methods for signal acquisition, processing, and decision-making. METHODS: In this work, non-standard electrode placement configurations (EPC) on the thoracic area and single arm were experimented for ECG signal acquisition. The locations were selected for joint acquisition of ECG and ICG, targeted to suitability for integrating into wearable devices. The methodology for comparing the detected signals of ECG was developed, presented, and applied to determine the R, S, and T waves and RR interval. An algorithm was proposed to distinguish the R waves in the case of large T waves. RESULTS: Results show the feasibility of using non-standard EPCs, manifesting in recognizable signal waveforms with reasonable quality for post-processing. A considerably lower median sensitivity of R wave was verified (27.3%) compared with T wave (49%) and S wave (44.9%) throughout the used data. The proposed algorithm for distinguishing R wave from large T wave shows satisfactory results. CONCLUSIONS: The most suitable non-standard locations for ECG monitoring in conjunction with ICG were determined and proposed.


Assuntos
Eletrocardiografia , Dispositivos Eletrônicos Vestíveis , Humanos , Eletrocardiografia/métodos , Arritmias Cardíacas , Eletrodos , Algoritmos
4.
Artigo em Inglês | MEDLINE | ID: mdl-34892775

RESUMO

ICG (impedance cardiography) and ECG (electrocardiography) provide important indications about functioning of the heart and of overall cardiovascular system. Measuring ICG along with ECG using wearable devices will improve the quality of health monitoring, as ICG points to important hemodynamic parameters (such as time intervals, stroke volume, cardiac output, and their variability). In this work, various electrode locations (12 different setups) have been tested for possible joint ECG & ICG data acquisition (using the same electrodes) and signal quality has been evaluated for every setup. It is shown that, while typically ICG is acquired over the whole thorax, a wrist-based joint acquisition of ECG & ICG signals can achieve acceptable signal quality and therefore can be considered in wearable sensing.


Assuntos
Cardiografia de Impedância , Débito Cardíaco , Impedância Elétrica , Eletrodos , Volume Sistólico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...