1.
Ultrasound Obstet Gynecol ; 49(6): 784-792, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27514486

RESUMO

OBJECTIVES: To validate externally the performance of the Assessment of Different NEoplasias in the adneXa (ADNEX) model and compare this model with other frequently used models in the differentiation between benign and malignant adnexal masses. METHODS: In this retrospective diagnostic accuracy study, we assessed data collected prospectively from patients with adnexal pathology who underwent real-time transvaginal or transrectal ultrasound by a single expert ultrasonographer in a tertiary care hospital between July 2011 and July 2015. The presence of a malignancy was determined by subjective assessment and use of four prediction models: the ADNEX model, simple ultrasound-based rules (simple rules), Logistic Regression model 2 (LR2) and the Risk of Malignancy Index (RMI), of which three different variants were assessed. Pathology was the clinical reference standard. RESULTS: In total, 851 consecutive patients underwent ultrasound examination for an adnexal mass. For 326 patients (128 premenopausal and 198 postmenopausal), pathology results were available (211 (64.7%) benign; 115 (35.3%) malignant) and these were included in the analysis. The area under the receiver-operating characteristics curve (AUC) of the ADNEX model for the discrimination between benign and malignant tumors was 0.93 (95% CI, 0.89-0.95). AUCs for the subtypes of malignancy (i.e. borderline, Stage I-IV and metastatic adnexal tumors) ranged between 0.60 and 0.90. Only subjective assessment (AUC, 0.96 (95% CI, 0.93-0.98)) was superior to the ADNEX model (P = 0.01) in differentiating malignant from benign tumors. AUCs for the other models were 0.92 (95% CI, 0.89-0.95) for LR2, 0.85 (95% CI, 0.81-0.89) for RMI-I, 0.82 (95% CI, 0.77-0.86) for RMI-II and 0.84 (95% CI, 0.80-0.88) for RMI-III. At the proposed cut-off of ≥ 10%, the ADNEX model had the highest sensitivity (0.98 (95% CI, 0.93-1.00)) but the lowest specificity (0.62 (95% CI, 0.55-0.68)) compared with the other models. Both subjective assessment (sensitivity, 0.90 (95% CI, 0.83-0.95); specificity 0.91 (95% CI, 0.86-0.94)) and the simple rules model with inconclusive cases classified by subjective assessment (sensitivity, 0.89 (95% CI, 0.81-0.94); specificity, 0.90 (95% CI, 0.85-0.94)) had lower sensitivity, but their sensitivity and specificity were better balanced. CONCLUSIONS: Although the test performance of subjective assessment by an expert remains superior, the ADNEX model can help in the differentiation between benign and malignant ovarian tumors. The advantage of the ADNEX model as a polytomous model remains to be shown. © 2016 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Doenças dos Anexos/diagnóstico por imagem , Estadiamento de Neoplasias , Doenças dos Anexos/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Pessoa de Meia-Idade , Modelos Teóricos , Países Baixos , Neoplasias Ovarianas/diagnóstico por imagem , Neoplasias Ovarianas/patologia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco , Ultrassonografia , Adulto Jovem
2.
Eur J Cancer ; 58: 17-29, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26922169

RESUMO

INTRODUCTION: Many national guidelines concerning the management of ovarian cancer currently advocate the risk of malignancy index (RMI) to characterise ovarian pathology. However, other methods, such as subjective assessment, International Ovarian Tumour Analysis (IOTA) simple ultrasound-based rules (simple rules) and IOTA logistic regression model 2 (LR2) seem to be superior to the RMI. Our objective was to compare the diagnostic accuracy of subjective assessment, simple rules, LR2 and RMI for differentiating benign from malignant adnexal masses prior to surgery. MATERIALS AND METHODS: MEDLINE, EMBASE and CENTRAL were searched (January 1990-August 2015). Eligibility criteria were prospective diagnostic studies designed to preoperatively predict ovarian cancer in women with an adnexal mass. RESULTS: We analysed 47 articles, enrolling 19,674 adnexal tumours; 13,953 (70.9%) benign and 5721 (29.1%) malignant. Subjective assessment by experts performed best with a pooled sensitivity of 0.93 (95% confidence interval [CI] 0.92-0.95) and specificity of 0.89 (95% CI 0.86-0.92). Simple rules (classifying inconclusives as malignant) (sensitivity 0.93 [95% CI 0.91-0.95] and specificity 0.80 [95% CI 0.77-0.82]) and LR2 (sensitivity 0.93 [95% CI 0.89-0.95] and specificity 0.84 [95% CI 0.78-0.89]) outperformed RMI (sensitivity 0.75 [95% CI 0.72-0.79], specificity 0.92 [95% CI 0.88-0.94]). A two-step strategy using simple rules, when inconclusive added by subjective assessment, matched test performance of subjective assessment by expert examiners (sensitivity 0.91 [95% CI 0.89-0.93] and specificity 0.91 [95% CI 0.87-0.94]). CONCLUSIONS: A two-step strategy of simple rules with subjective assessment for inconclusive tumours yielded best results and matched test performance of expert ultrasound examiners. The LR2 model can be used as an alternative if an expert is not available.


Assuntos
Técnicas de Apoio para a Decisão , Modelos Biológicos , Neoplasias Ovarianas/diagnóstico por imagem , Ultrassonografia Doppler em Cores , Diagnóstico Diferencial , Feminino , Humanos , Modelos Logísticos , Neoplasias Ovarianas/cirurgia , Valor Preditivo dos Testes , Prognóstico , Reprodutibilidade dos Testes