Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ACS Nano ; 15(1): 447-454, 2021 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-33381965

RESUMO

Graphene is a promising material for many biointerface applications in engineering, medical, and life-science domains. Here, we explore the protection ability of graphene atomic layers to metals exposed to aggressive sulfate-reducing bacteria implicated in corrosion. Although the graphene layers on copper (Cu) surfaces did not prevent the bacterial attachment and biofilm growth, they effectively restricted the biogenic sulfide attack. Interestingly, single-layered graphene (SLG) worsened the biogenic sulfide attack by 5-fold compared to bare Cu. In contrast, multilayered graphene (MLG) on Cu restricted the attack by 10-fold and 1.4-fold compared to SLG-Cu and bare Cu, respectively. We combined experimental and computational studies to discern the anomalous behavior of SLG-Cu compared to MLG-Cu. We also report that MLG on Ni offers superior protection ability compared to SLG. Finally, we demonstrate the effect of defects, including double vacancy defects and grain boundaries on the protection ability of atomic graphene layers.


Assuntos
Desulfovibrio , Grafite , Biofilmes , Cobre , Corrosão
2.
RSC Adv ; 9(16): 8778-8881, 2019 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-35517682

RESUMO

Biosensors with high sensitivity, selectivity and a low limit of detection, reaching nano/picomolar concentrations of biomolecules, are important to the medical sciences and healthcare industry for evaluating physiological and metabolic parameters. Over the last decade, different nanomaterials have been exploited to design highly efficient biosensors for the detection of analyte biomolecules. The discovery of graphene has spectacularly accelerated research on fabricating low-cost electrode materials because of its unique physical properties, including high specific surface area, high carrier mobility, high electrical conductivity, flexibility, and optical transparency. Graphene and its oxygenated derivatives, including graphene oxide (GO) and reduced graphene oxide (rGO), are becoming an important class of nanomaterials in the field of biosensors. The presence of oxygenated functional groups makes GO nanosheets strongly hydrophilic, facilitating chemical functionalization. Graphene, GO and rGO nanosheets can be easily combined with various types of inorganic nanoparticles, including metals, metal oxides, semiconducting nanoparticles, quantum dots, organic polymers and biomolecules, to create a diverse range of graphene-based nanocomposites with enhanced sensitivity for biosensor applications. This review summarizes the advances in two-dimensional (2D) and three-dimensional (3D) graphene-based nanocomposites as emerging electrochemical and fluorescent biosensing platforms for the detection of a wide range of biomolecules with enhanced sensitivity, selectivity and a low limit of detection. The biofunctionalization and nanocomposite formation processes of graphene-based materials and their unique properties, surface functionalization, enzyme immobilization strategies, covalent immobilization, physical adsorption, biointeractions and direct electron transfer (DET) processes are discussed in connection with the design and fabrication of biosensors. The enzymatic and nonenzymatic reactions on graphene-based nanocomposite surfaces for glucose- and cholesterol-related electrochemical biosensors are analyzed. This review covers a very broad range of graphene-based electrochemical and fluorescent biosensors for the detection of glucose, cholesterol, hydrogen peroxide (H2O2), nucleic acids (DNA/RNA), genes, enzymes, cofactors nicotinamide adenine dinucleotide (NADH) and adenosine triphosphate (ATP), dopamine (DA), ascorbic acid (AA), uric acid (UA), cancer biomarkers, pathogenic microorganisms, food toxins, toxic heavy metal ions, mycotoxins, and pesticides. The sensitivity and selectivity of graphene-based electrochemical and fluorescent biosensors are also examined with respect to interfering analytes present in biological systems. Finally, the future outlook for the development of graphene based biosensing technology is outlined.

3.
Sci Total Environ ; 656: 808-833, 2019 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-30530150

RESUMO

The steady increase in population, coupled with the rapid utilization of resources and continuous development of industry and agriculture has led to excess amounts of wastewater with changes in its composition, texture, complexity and toxicity due to the diverse range of pollutants being present in wastewater. The challenges faced by wastewater treatment today are mainly with the complexity of the wastewater as it complicates treatment processes by requiring a combination of technologies, thus resulting in longer treatment times and higher operational costs. Nanotechnology opens up a novel platform that is free from secondary pollution, inexpensive and an effective way to simultaneously remove multiple pollutants from wastewater. Currently, there are a number of studies that have presented a myriad of multi-purpose/multifunctional nanoparticles that simultaneously remove multiple pollutants in water. However, these studies have not been collated to review the direction that nanoparticle assisted wastewater treatment is heading towards. Hence, this critical review explores the feasibility and efficiency of simultaneous removal of co-existing/multiple pollutants in water using nanomaterials. The discussion begins with an introduction of different classes of pollutants and their toxicity followed by an overview and highlights of current research on multipollutant control in water using different nanomaterials as adsorbents, photocatalysts, disinfectants and microbicides. The analysis is concluded with a look at the current attempts being made towards commercialization of multipollutant control/multifunctional nanotechnology inventions. The review presents evidence of simultaneous removal of pathogenic microorganisms, inorganic and organic compound chemical pollutants using nanoparticles. Accordingly, not only is nanotechnology showcased as a promising and an environmentally-friendly way to solve the limitations of current and conventional centralised water and wastewater treatment facilities but is also presented as a good substitute or supplement in areas without those facilities.

4.
Sensors (Basel) ; 18(6)2018 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-29799505

RESUMO

Foodborne illness is correlated with the existence of infectious pathogens such as bacteria in food and drinking water. Probe-modified graphene field effect transistors (G-FETs) have been shown to be suitable for Escherichia coli (E. coli) detection. Here, the G-FETs for bacterial detection are modeled and simulated with COMSOL Multiphysics to understand the operation of the biosensors. The motion of E. coli cells in electrolyte and the surface charge of graphene induced by E. coli are systematically investigated. The comparison between the simulation and experimental data proves the sensing probe size to be a key parameter affecting the surface charge of graphene induced by bacteria. Finally, the relationship among the change in source-drain current (∆Ids), graphene-bacteria distance and bacterial concentration is established. The shorter graphene-bacteria distance and higher bacterial concentration give rise to better sensing performance (larger ∆Ids) of the G-FETs biosensors. The simulation here could serve as a guideline for the design and optimization of G-FET biosensors for various applications.


Assuntos
Técnicas Biossensoriais , Escherichia coli/isolamento & purificação , Doenças Transmitidas por Alimentos/diagnóstico , Grafite/química , Escherichia coli/patogenicidade , Doenças Transmitidas por Alimentos/microbiologia , Humanos , Transistores Eletrônicos
6.
Nanotechnology ; 22(40): 405203, 2011 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-21896980

RESUMO

The development of display scan drivers is an essential step in the effort to develop transparent and flexible display devices based on nanowire transistors. Here we report a transparent nanowire-based shift register that functions as the standard logic circuit of a display scan driver. To form the shift register circuits using only n-type nanowire transistors, a novel circuit structure was introduced to avoid the output voltage drop typical of purely n-type circuits. A circuit simulation based on the measured nanowire transistor characteristics was developed in the planning phase to verify the circuit operation of the shift register. The shift register successfully produced an output of 0-3 V without an output voltage drop while applying an input of 3 V peak to peak. In addition, the shift register was designed to have multiple channels with a randomly oriented nanowire placement method to enhance the operation yield.

7.
Nanotechnology ; 20(43): 430203, 2009 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-19805859
9.
Biomed Microdevices ; 6(1): 55-60, 2004 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15307445

RESUMO

Mutations in BRCA1 are characterized by predisposition to breast cancer, ovarian cancer and prostate cancer as well as colon cancer. Prognosis for this cancer survival depends upon the stage at which cancer is diagnosed. Reliable and rapid mutation detection is crucial for the early diagnosis and treatment. We developed an electronic assay for the detection of a representative single nucleotide polymorphism (SNP), deletion and insertion in BRCA1 gene by the microelectronics microarray instrumentation. The assay is rapid, and it takes 30 minutes for the immobilization of target DNA samples, hybridization, washing and readout. The assay is multiplexing since it is carried out at the same temperature and buffer conditions for each step. The assay is also highly specific, as the signal-to-noise ratio is much larger than recommended value (72.86 to 321.05 vs. 5) for homozygotes genotyping, and signal ratio close to the perfect value 1 for heterozygotes genotyping (1.04).


Assuntos
Proteína BRCA1/genética , Biomarcadores Tumorais/genética , Neoplasias da Mama/metabolismo , Análise Mutacional de DNA/instrumentação , Análise de Falha de Equipamento , Perfilação da Expressão Gênica/instrumentação , Análise de Sequência com Séries de Oligonucleotídeos/instrumentação , Adulto , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/genética , Análise Mutacional de DNA/métodos , Eletrônica Médica , Desenho de Equipamento , Feminino , Perfilação da Expressão Gênica/métodos , Humanos , Pessoa de Meia-Idade , Miniaturização/métodos , Análise de Sequência com Séries de Oligonucleotídeos/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
Clin Chem ; 50(10): 1886-93, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15319319

RESUMO

BACKGROUND: Reducing cost and time is the major concern in clinical diagnostics, particularly in molecular diagnostics. Miniaturization technologies have been recognized as promising solutions to provide low-cost microchips for diagnostics. With the recent advancement in nanotechnologies, it is possible to further improve detection sensitivity and simplify sample preparation by incorporating nanoscale elements in diagnostics devices. A fusion of micro- and nanotechnologies with biology has great potential for the development of low-cost disposable chips for rapid molecular analysis that can be carried out with simple handheld devices. APPROACH: Vertically aligned multiwalled carbon nanotubes (MWNTs) are fabricated on predeposited microelectrode pads and encapsulated in SiO2 dielectrics with only the very end exposed at the surface to form an inlaid nanoelectrode array (NEA). The NEA is used to collect the electrochemical signal associated with the target molecules binding to the probe molecules, which are covalently attached to the end of the MWNTs. CONTENT: A 3 x 3 microelectrode array is presented to demonstrate the miniaturization and multiplexing capability. A randomly distributed MWNT NEA is fabricated on each microelectrode pad. Selective functionalization of the MWNT end with a specific oligonucleotide probe and passivation of the SiO2 surface with ethylene glycol moieties are discussed. Ru(bpy)2+ -mediator-amplified guanine oxidation is used to directly measure the electrochemical signal associated with target molecules. SUMMARY: The discussed MWNT NEAs have ultrahigh sensitivity in direct electrochemical detection of guanine bases in the nucleic acid target. Fewer than approximately 1000 target nucleic acid molecules can be measured with a single microelectrode pad of approximately 20 x 20 microm2, which approaches the detection limit of laser scanners in fluorescence-based DNA microarray techniques. MWNT NEAs can be easily integrated with microelectronic circuitry and microfluidics for development of a fully automated system for rapid molecular analysis with minimum cost.


Assuntos
Carbono , Ácidos Nucleicos/análise , Algoritmos , DNA/análise , Eletroquímica , Eletrodos , Nanotecnologia , Análise de Sequência com Séries de Oligonucleotídeos/instrumentação , Análise de Sequência com Séries de Oligonucleotídeos/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...