Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.977
Filtrar
1.
Biomed Chromatogr ; : e5986, 2024 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-39136165

RESUMO

Small molecule inhibitors (SMIs) are increasingly being used in the treatment of non-small cell lung cancer. To support pharmacokinetic research and clinical treatment monitoring, our aim was to develop and validate an ultra-performance liquid chromatography-mass spectrometry (UPLC-MS/MS) assay for quantification of eight SMIs: adagrasib, alectinib, brigatinib, capmatinib, crizotinib, lorlatinib, selpercatinib, and sotorasib. Development of the UPLC-MS/MS assay was done by trying different columns and eluents to optimize peak shape. The assay was validated based on guidelines of the European Medicines Agency. Chromatographic separation was performed with a gradient elution using ammonium formate in water and methanol. Detection was performed using a triple quadrupole tandem mass spectrometer with electrospray ionization. Validation was performed in a range of 10-2500 µg/L for lorlatinib, 25-6250 µg/L for alectinib and crizotinib, 25-10,000 µg/L for capmatinib and selpercatinib, 50-12,500 µg/L for brigatinib, and 100-25,000 µg/L for adagrasib and sotorasib. Imprecision was <8.88% and inaccuracy was <12.5% for all compounds. Seven out of eight compounds were stable for 96 h at room temperature. Sotorasib was stable for 8 h at room temperature. A sensitive and reliable method has been developed to quantify eight SMIs with a single assay, enhancing efficacy and safety of targeted therapies.

2.
Phys Rev E ; 109(6-1): 064801, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39020907

RESUMO

Nanoporous materials provide high surface area per unit mass and are capable of fluids adsorption. While the measurements of the overall amount of fluid adsorbed by a nanoporous sample are straightforward, probing the spatial distribution of fluids is nontrivial. We consider literature data on adsorption and desorption of fluids in nanoporous glasses reported along with the measurements of ultrasonic wave propagation. We analyze these using the so-called dynamic equivalent medium approach, which is based on Biot's theory of dynamic poroelasticity with coefficients that are continuous random functions of position. When further constrained by optical scattering data for similar systems, the calculations show that on adsorption the characteristic patch size is of the order of 100 pore diameters, while on desorption the patch size is comparable to the sample size. Our analysis suggests that one can employ ultrasound to probe the uniformity of the spatial distribution of fluids in nanoporous materials.

4.
Ann Vasc Surg ; 108: 426-436, 2024 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-39004276

RESUMO

BACKGROUND: No evaluation of the quality of different carotid guidelines using validated scales has been performed to date. The present study aims to analyze 3 carotid stenosis guidelines, apprizing their quality and reporting using validated tools. METHODS: A survey-based assessment of the quality of the European Society for Vascular Surgery (ESVS) 2023, European Stroke Organisation (ESO) 2021, and the Society for Vascular Surgery (SVS) 2021 carotid stenosis guidelines, was performed by 43 vascular surgeons, cardiologists, neurologist or interventional radiologists using 2 validated appraisal tools for quality and reporting guidelines, the AGREE II instrument and the RIGHT statement. RESULTS: Using the AGREE II tool, the ESVS, SVS, and ESO guidelines had overall quality scores of 87.3%, 79.4%, and 82.9%, respectively (P = 0.001) The ESVS and ESO had better scores in the scope and purpose domain, and the SVS in the clarity of presentation domain. In the RIGHT statement, the ESVS, SVS, and ESO guidelines had overall quality scores of 84.0.7%, 74.3%, and 79.0%, respectively (P = 0.001). All 3 guidelines stood out for their methodology for search of evidence and formulating evidence-based recommendations. On the contrary, were negatively evaluated mostly in the cost and resource implications in formulating the recommendations. CONCLUSIONS: The 2023 ESVS carotid stenosis guideline was the best evaluated among the 3 guidelines, with scores over 5% higher than the other 2 guidelines. Efforts should be made by guideline writing committees to take the AGREE II and RIGHT statements into account in the development of future guidelines to produce high-quality recommendations.

5.
PLoS One ; 19(7): e0293707, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39083541

RESUMO

BACKGROUND: The efficacy of PD-1 blocking agents in advanced NSCLC has shown prolonged effectiveness, but only in a minority of patients. Multiple biomarkers have been explored to predict treatment benefit, yet their combined performance remains inadequately examined. In this study, we assessed the combined predictive performance of multiple biomarkers in NSCLC patients treated with nivolumab. METHODS: Pretreatment samples from 135 patients receiving nivolumab were used to evaluate the predictive performance of CD8 tumor-infiltrating lymphocytes (TILs), intratumoral (IT) localization of CD8 TILs, PD-1 high expressing TILs (PD1T TILs), CD3 TILs, CD20 B-cells, tertiary lymphoid structures (TLS), PD-L1 tumor proportion score (TPS) and the Tumor Inflammation score (TIS). Patients were randomly assigned to a training (n = 55) and validation cohort (n = 80). The primary outcome measure was Disease Control at 6 months (DC 6m) and the secondary outcome measure was DC at 12 months (DC 12m). RESULTS: In the validation cohort, the two best performing composite biomarkers (i.e. CD8+IT-CD8 and CD3+IT-CD8) demonstrated similar or lower sensitivity (64% and 83%) and NPV (76% and 85%) compared to individual biomarkers PD-1T TILs and TIS (sensitivity: 72% and 83%, NPV: 86% and 84%) for DC 6m, respectively. Additionally, at 12 months, both selected composite biomarkers (CD8+IT-CD8 and CD8+TIS) demonstrated inferior predictive performance compared to PD-1T TILs and TIS alone. PD-1T TILs and TIS showed high sensitivity (86% and 100%) and NPV (95% and 100%) for DC 12m. PD-1T TILs could more accurately discriminate patients with no long-term benefit, as specificity was substantially higher compared to TIS (74% versus 39%). CONCLUSION: Composite biomarkers did not show improved predictive performance compared to PD-1T TILs and TIS alone for both the 6- and 12-month endpoints. PD-1T TILs and TIS identified patients with DC 12m with high sensitivity. Patients with no long-term benefit to PD-1 blockade were most accurately identified by PD-1T TILs.


Assuntos
Biomarcadores Tumorais , Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Linfócitos do Interstício Tumoral , Nivolumabe , Receptor de Morte Celular Programada 1 , Humanos , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Masculino , Feminino , Neoplasias Pulmonares/tratamento farmacológico , Neoplasias Pulmonares/imunologia , Biomarcadores Tumorais/metabolismo , Pessoa de Meia-Idade , Idoso , Linfócitos do Interstício Tumoral/imunologia , Receptor de Morte Celular Programada 1/antagonistas & inibidores , Nivolumabe/uso terapêutico , Inibidores de Checkpoint Imunológico/uso terapêutico , Resultado do Tratamento , Adulto , Linfócitos T CD8-Positivos/imunologia , Linfócitos T CD8-Positivos/efeitos dos fármacos , Linfócitos T CD8-Positivos/metabolismo
6.
Sci Rep ; 14(1): 17262, 2024 07 27.
Artigo em Inglês | MEDLINE | ID: mdl-39068299

RESUMO

Accurate intraoperative assessment of organ perfusion is a pivotal determinant in preserving organ function e.g. during kidney surgery including partial nephrectomy or kidney transplantation. Hyperspectral imaging (HSI) has great potential to objectively describe and quantify this perfusion as opposed to conventional surrogate techniques such as ultrasound flowmeter, indocyanine green or the subjective eye of the surgeon. An established live porcine model under general anesthesia received median laparotomy and renal mobilization. Different scenarios that were measured using HSI were (1) complete, (2) gradual and (3) partial malperfusion. The differences in spectral reflectance as well as HSI oxygenation (StO2) between different perfusion states were compelling and as high as 56.9% with 70.3% (± 11.0%) for "physiological" vs. 13.4% (± 3.1%) for "venous congestion". A machine learning (ML) algorithm was able to distinguish between these perfusion states with a balanced prediction accuracy of 97.8%. Data from this porcine study including 1300 recordings across 57 individuals was compared to a human dataset of 104 recordings across 17 individuals suggesting clinical transferability. Therefore, HSI is a highly promising tool for intraoperative microvascular evaluation of perfusion states with great advantages over existing surrogate techniques. Clinical trials are required to prove patient benefit.


Assuntos
Imageamento Hiperespectral , Rim , Animais , Suínos , Rim/irrigação sanguínea , Rim/diagnóstico por imagem , Rim/cirurgia , Imageamento Hiperespectral/métodos , Humanos , Inteligência Artificial , Nefrectomia/métodos , Perfusão/métodos
7.
PLoS One ; 19(7): e0304413, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38954679

RESUMO

BACKGROUND: Sedatives are commonly used to promote sleep in intensive care unit patients. However, it is not clear whether sedation-induced states are similar to the biological sleep. We explored if sedative-induced states resemble biological sleep using multichannel electroencephalogram (EEG) recordings. METHODS: Multichannel EEG datasets from two different sources were used in this study: (1) sedation dataset consisting of 102 healthy volunteers receiving propofol (N = 36), sevoflurane (N = 36), or dexmedetomidine (N = 30), and (2) publicly available sleep EEG dataset (N = 994). Forty-four quantitative time, frequency and entropy features were extracted from EEG recordings and were used to train the machine learning algorithms on sleep dataset to predict sleep stages in the sedation dataset. The predicted sleep states were then compared with the Modified Observer's Assessment of Alertness/ Sedation (MOAA/S) scores. RESULTS: The performance of the model was poor (AUC = 0.55-0.58) in differentiating sleep stages during propofol and sevoflurane sedation. In the case of dexmedetomidine, the AUC of the model increased in a sedation-dependent manner with NREM stages 2 and 3 highly correlating with deep sedation state reaching an AUC of 0.80. CONCLUSIONS: We addressed an important clinical question to identify biological sleep promoting sedatives using EEG signals. We demonstrate that propofol and sevoflurane do not promote EEG patterns resembling natural sleep while dexmedetomidine promotes states resembling NREM stages 2 and 3 sleep, based on current sleep staging standards.


Assuntos
Dexmedetomidina , Eletroencefalografia , Hipnóticos e Sedativos , Aprendizado de Máquina , Propofol , Sevoflurano , Sono , Humanos , Hipnóticos e Sedativos/farmacologia , Hipnóticos e Sedativos/administração & dosagem , Masculino , Adulto , Feminino , Sono/efeitos dos fármacos , Sono/fisiologia , Propofol/farmacologia , Propofol/administração & dosagem , Sevoflurano/farmacologia , Sevoflurano/efeitos adversos , Sevoflurano/administração & dosagem , Dexmedetomidina/farmacologia , Fases do Sono/efeitos dos fármacos , Adulto Jovem
8.
World J Urol ; 42(1): 396, 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38985296

RESUMO

PURPOSE: To investigate and implement semiautomated screening for meta-analyses (MA) in urology under consideration of class imbalance. METHODS: Machine learning algorithms were trained on data from three MA with detailed information of the screening process. Different methods to account for class imbalance (Sampling (up- and downsampling, weighting and cost-sensitive learning), thresholding) were implemented in different machine learning (ML) algorithms (Random Forest, Logistic Regression with Elastic Net Regularization, Support Vector Machines). Models were optimized for sensitivity. Besides metrics such as specificity, receiver operating curves, total missed studies, and work saved over sampling were calculated. RESULTS: During training, models trained after downsampling achieved the best results consistently among all algorithms. Computing time ranged between 251 and 5834 s. However, when evaluated on the final test data set, the weighting approach performed best. In addition, thresholding helped to improve results as compared to the standard of 0.5. However, due to heterogeneity of results no clear recommendation can be made for a universal sample size. Misses of relevant studies were 0 for the optimized models except for one review. CONCLUSION: It will be necessary to design a holistic methodology that implements the presented methods in a practical manner, but also takes into account other algorithms and the most sophisticated methods for text preprocessing. In addition, the different methods of a cost-sensitive learning approach can be the subject of further investigations.


Assuntos
Aprendizado de Máquina , Metanálise como Assunto , Revisões Sistemáticas como Assunto , Urologia , Humanos , Algoritmos
9.
Nanotechnology ; 35(37)2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38897181

RESUMO

While silver nanowires (Ag NWs) have been demonstrated as a highly efficient transparent conducting material, they suffer from strong light scattering, which is quantified by a large haze factor (HF) in the optical spectrum. Here we investigate the influence of the dielectric environment on the light scattering of Ag NWs by comparing experimental measurements and simulations. In air, two peaks on the HF spectra are observed experimentally at the wavelength ofλI= 350 nm andλII= 380 nm and are attributed by simulations to the influence of the Ag NWs pentagonal shape on the localized surface plasmon resonance. The relative intensity between the two peaks is found to be dependent on whether the Ag NWs are in contact with the glass substrate or not. The HF behaviour in the near IR region seems to be dominated by Rayleigh scattering following simulations results. Dielectric environments of Ag NWs with various refractive indexes were obtained experimentally by the conformal deposition of different metal oxide coatings using atomic layer deposition, including Al-doped zinc oxide, Al2O3and SiO2coatings. The HF is found to be correlated with the refractive index environment in terms of HF peaks position, intensity and broadening. This trend of HF peaks is supported by a theoretical model to understand the optical mechanism behind this phenomenon.

10.
Artigo em Inglês | MEDLINE | ID: mdl-38871213

RESUMO

OBJECTIVE: One year aneurysm sac dynamics after endovascular abdominal aortic aneurysm repair (EVAR) were independently associated with a greater all cause mortality risk in prior registry studies but were limited in completeness and granularity. This retrospective analysis aimed to study the impact of sac dynamics on survival within the Endurant Stent Graft Global Registry (ENGAGE) with five year follow up. METHODS: A total of 1 263 subjects were enrolled in the ENGAGE Registry between March 2009 and April 2011. One year aneurysm sac changes were calculated between the one month post-operative imaging scans and the scan closest to the time of one year follow up. Sac regression was defined as a sac decrease of ≥ 5 mm and sac expansion as aneurysm sac growth ≥ 5 mm. The primary outcome was the five year all cause mortality rate. Kaplan-Meier estimates for freedom from all cause death were calculated. Multivariable Cox regression was used to determine the association between sac dynamics and all cause death. RESULTS: At one year, 441 of the 949 study participants with appropriate imaging (46%) had abdominal aortic aneurysm sac regression, 462 (49%) remained stable, and 46 (4.8%) had sac expansion. For patients with sac regression, the five year all cause mortality rate was 20%, compared with 28% for stable sac (p = .007) and 37% for the sac expansion (p = .010) cohorts. After adjustment, the sac expansion and stable sac cohorts were associated with a greater all cause mortality rate (expansion: hazard ratio [HR] 1.8; 95% CI 1.1 - 3.2; p = .032; stable: HR 1.4; 95% CI 1.1 - 1.9; p = .019). CONCLUSION: In the ENGAGE Global Registry, the one year rate of sac regression was 46%, and one year sac regression was observed to be associated with greater five year survival, corroborating prior findings using data from vascular registries. Sac regression could become the new standard for success after EVAR.

11.
Br J Cancer ; 131(3): 481-490, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38862741

RESUMO

BACKGROUND: Small-molecule inhibitors (SMIs) have revolutionised the treatment of non-small cell lung cancer (NSCLC). However, SMI-induced drug-drug interactions (DDIs) with frequently co-administered direct oral anticoagulants (DOACs), increase thromboembolic and bleeding risks. This study investigated and proactively managed the consequences of DOAC-SMI DDIs. METHODS: This prospective, observational study enrolled patients with NSCLC concomitantly using a DOAC and SMI. The primary outcome was the proportion of patients with DOAC plasma trough (Ctrough) and peak (Cpeak) concentrations outside expected ranges. Secondary outcomes included DOAC treatment modifications, incidence of bleeding and thromboembolic events and feasibility evaluation of pharmacokinetically guided DOAC dosing. RESULTS: Thirty-three patients were analysed. Thirty-nine percent (13/33) had DOAC Ctrough and/or Cpeak were outside the expected ranges in 39% (13/33). In 71% (5/7) of patients with DOAC concentrations quantified before and during concurrent SMI use, DOAC Ctrough and/or Cpeak increased or decreased >50% upon SMI initiation. In all patients in whom treatment modifications were deemed necessary, DOAC concentrations were adjusted to within the expected ranges. CONCLUSION: Proactive monitoring showed that a substantial proportion of patients had DOAC concentrations outside the expected ranges. DOAC concentrations were successfully normalised after treatment modifications. These results highlight the importance of proactive monitoring of DOAC-SMI DDIs to improve treatment in patients with NSCLC.


Assuntos
Anticoagulantes , Carcinoma Pulmonar de Células não Pequenas , Interações Medicamentosas , Neoplasias Pulmonares , Humanos , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Neoplasias Pulmonares/tratamento farmacológico , Masculino , Feminino , Idoso , Estudos Prospectivos , Pessoa de Meia-Idade , Anticoagulantes/administração & dosagem , Anticoagulantes/farmacocinética , Anticoagulantes/uso terapêutico , Administração Oral , Idoso de 80 Anos ou mais , Hemorragia/induzido quimicamente , Monitoramento de Medicamentos/métodos , Inibidores do Fator Xa/uso terapêutico , Inibidores do Fator Xa/farmacocinética , Inibidores do Fator Xa/administração & dosagem , Tromboembolia/prevenção & controle
12.
Target Oncol ; 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38890221

RESUMO

BACKGROUND: The antibody-drug conjugate sacituzumab govitecan is approved for metastatic triple-negative breast cancer and has shown promising results in various other types of cancer. Its costs may limit patient access to this novel effective treatment modality. OBJECTIVE: The purpose of this study was to develop an evidence-based rational dosing regimen that results in targeted drug exposure within the therapeutic range while minimizing financial toxicity, to improve treatment access. PATIENTS AND METHODS: Exposure equivalent dosing strategies were developed based on pharmacokinetic modeling and simulation by using the published pharmacokinetic model developed by the license holder. The alternative dose was based on the principle of using complete vials to prevent spillage and on the established non-linear relationship between body weight and systemic exposure. Equivalent exposure compared to the approved dosing regimen of 10 mg/kg was aimed for. Equivalent exposure was conservatively defined as calculated geometric mean ratios within the 0.9-1.11 boundaries for area under the concentration-time curve (AUC), trough concentration (Ctrough) and maximum concentration (Cmax) of the alternative dosing regimen compared to the approved dosing regimen. Since different vial sizes are available for the European Union (EU) and United States (US) market, because body weight distributions differ between these populations, we performed our analysis for both scenarios. RESULTS: Dosing regimens of sacituzumab govitecan for the EU (< 50 kg: 400 mg, 50-80 kg: 600 mg, and > 80 kg: 800 mg) and US population (< 40 kg: 360 mg, 40-65 kg: 540 mg, 65-90 kg: 720 mg, and > 90 kg: 900 mg) were developed, based on weight bands. The geometric mean ratios for all pharmacokinetic outcomes were within the predefined equivalence boundaries, while the quantity of drug used was 21.5% and 19.0% lower for the EU and US scenarios, respectively. CONCLUSIONS: With the alternative dosing proposal, an approximately 20% reduction in drug expenses for sacituzumab govitecan can be realized while maintaining an equivalent and more evenly distributed exposure throughout the body weight range, without notable increases in pharmacokinetic variability.

13.
Invest Ophthalmol Vis Sci ; 65(6): 9, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38837167

RESUMO

Purpose: Optical coherence tomography (OCT) representations in clinical practice are static and do not allow for a dynamic visualization and quantification of blood flow. This study aims to present a method to analyze retinal blood flow dynamics using time-resolved structural OCT. Methods: We developed novel imaging protocols to acquire video-rate time-resolved OCT B-scans (1024 × 496 pixels, 10 degrees field of view) at four different sensor integration times (integration time of 44.8 µs at a nominal A-scan rate of 20 kHz, 22.4 µs at 40 kHz, 11.2 µs at 85 kHz, and 7.24 µs at 125 kHz). The vessel centers were manually annotated for each B-scan and surrounding subvolumes were extracted. We used a velocity model based on signal-to-noise ratio (SNR) drops due to fringe washout to calculate blood flow velocity profiles in vessels within five optic disc diameters of the optic disc rim. Results: Time-resolved dynamic structural OCT revealed pulsatile SNR changes in the analyzed vessels and allowed the calculation of potential blood flow velocities at all integration times. Fringe washout was stronger in acquisitions with longer integration times; however, the ratio of the average SNR to the peak SNR inside the vessel was similar across all integration times. Conclusions: We demonstrated the feasibility of estimating blood flow profiles based on fringe washout analysis, showing pulsatile dynamics in vessels close to the optic nerve head using structural OCT. Time-resolved dynamic OCT has the potential to uncover valuable blood flow information in clinical settings.


Assuntos
Fluxo Sanguíneo Regional , Vasos Retinianos , Tomografia de Coerência Óptica , Tomografia de Coerência Óptica/métodos , Humanos , Vasos Retinianos/fisiologia , Vasos Retinianos/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo/fisiologia , Fluxo Sanguíneo Regional/fisiologia , Disco Óptico/irrigação sanguínea , Disco Óptico/diagnóstico por imagem , Razão Sinal-Ruído , Masculino , Feminino , Adulto , Pessoa de Meia-Idade
14.
JSES Rev Rep Tech ; 4(2): 189-195, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38706678

RESUMO

Background: In baseball, repetitive pitching leads to medial elbow injuries, particularly to the ulnar collateral ligament (UCL). To prevent pitchers from UCL injuries, it is important to quantify the response to elbow stress. Repetitive elbow external valgus torque and muscular fatigue induced by repetitive pitching could affect markers of the response, that is, humeroulnar joint gap and UCL morphology. The aims of the study were three-folded: to investigate the effect of (1) exerted handgrip force on the humeroulnar joint gap, (2) repetitive pitching on the humeroulnar joint gap and the UCL morphology, and (3) exerted handgrip force on the humeroulnar joint gap for different levels of elbow valgus stress is different after compared to before repetitive pitching in asymptomatic baseball pitchers. Methods: Medial elbow ultrasound images were collected in 15 asymptomatic male baseball pitchers. Three levels of static elbow valgus stress (0N, 50N, 100N) were applied with a TELOS device before and after repetitive pitching and with or without handgrip force. These images were used to assess the humeroulnar joint gap size and UCL length and thickness. After 110 fastball pitches or when 80% self-perceived fatigue on a VAS scale was reached, participants were instructed to stop throwing. Repeated measures ANOVAs were used to statistically test significant differences. Results: Handgrip force did not significantly affect the humeroulnar joint gap. The UCL thickness and length and the humeroulnar joint gap were also not different after compared to before repetitive pitching. While higher levels of applied valgus stress significantly increased the humeroulnar joint gap (P < .001), this effect was not significantly different in the interaction with handgrip force and repetitive pitching. Conclusion: The humeroulnar joint gap changes for different levels of elbow valgus stress. However, adult baseball pitchers did not respond to elbow stress after a single pitching session with or without submaximal handgrip force in the humeroulnar joint gap and UCL morphology.

15.
J Med Imaging (Bellingham) ; 11(3): 037001, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38765874

RESUMO

Purpose: To investigate the accuracy of high-framerate echo particle image velocimetry (ePIV) and computational fluid dynamics (CFD) for determining velocity vectors in femoral bifurcation models through comparison with optical particle image velocimetry (oPIV). Approach: Separate femoral bifurcation models were built for oPIV and ePIV measurements of a non-stenosed (control) and a 75%-area stenosed common femoral artery. A flow loop was used to create triphasic pulsatile flow. In-plane velocity vectors were measured with oPIV and ePIV. Flow was simulated with CFD using boundary conditions from ePIV and additional duplex-ultrasound (DUS) measurements. Mean differences and 95%-limits of agreement (1.96*SD) of the velocity magnitudes in space and time were compared, and the similarity of vector complexity (VC) and time-averaged wall shear stress (TAWSS) was assessed. Results: Similar flow features were observed between modalities with velocities up to 110 and 330 cm/s in the control and the stenosed model, respectively. Relative to oPIV, ePIV and CFD-ePIV showed negligible mean differences in velocity (<3 cm/s), with limits of agreement of ±25 cm/s (control) and ±34 cm/s (stenosed). CFD-DUS overestimated velocities with limits of agreements of 13±40 and 16.1±55 cm/s for the control and stenosed model, respectively. VC showed good agreement, whereas TAWSS showed similar trends but with higher values for ePIV, CFD-DUS, and CFD-ePIV compared to oPIV. Conclusions: EPIV and CFD-ePIV can accurately measure complex flow features in the femoral bifurcation and around a stenosis. CFD-DUS showed larger deviations in velocities making it a less robust technique for hemodynamical assessment. The applied ePIV and CFD techniques enable two- and three-dimensional assessment of local hemodynamics with high spatiotemporal resolution and thereby overcome key limitations of current clinical modalities making them an attractive and cost-effective alternative for hemodynamical assessment in clinical practice.

17.
Clin Implant Dent Relat Res ; 26(4): 688-703, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38693759

RESUMO

This study aimed to compare implant stabilities between the immediate and early loaded, immediately placed bone-level tapered dental implants in the maxilla and to evaluate marginal bone loss (MBL), oral health-related quality of life (OHRQoL), and patient satisfaction at a 2-year follow-up. A pilot, prospective, randomized, controlled clinical trial was conducted on 24 maxillary failing dentition patients. The bone-level tapered implants of 12 patients were immediately loaded with temporary restorations, while the other 12 patients did not receive any kind of temporization. Implant-supported screw-retained complete porcelain-fused-to-metal prostheses were delivered to all patients in the seventh postoperative week. The insertion torque values of implants assigned to the immediate and early loading groups were 33.0 ± 4.87 and 29.26 ± 8.31 Ncm, respectively. The dynamics of implant stability changes from implant placement up to a 2-year follow-up were similar for both groups (Penguin®, p = 0.268; Ostell®, p = 0.552), while the MBL was at submillimeter level. The cumulative implant survival rate was 91.80% for immediately loaded implants and 97.22% for early loaded implants, without significant difference (p = 0.162). The total score on the Oral Health Impact Profile questionnaire significantly decreased over time in both groups, indicating improvement in OHRQoL (p < 0.001), and the high level of patient satisfaction remained after 2 years of function regardless of a loading protocol. Both loading protocols, immediate and early, of six immediately placed bone-level tapered dental implants are an adequate treatment choice for fixed rehabilitation of the maxillary failing dentition.


Assuntos
Implantes Dentários , Carga Imediata em Implante Dentário , Maxila , Humanos , Carga Imediata em Implante Dentário/métodos , Projetos Piloto , Feminino , Maxila/cirurgia , Masculino , Seguimentos , Pessoa de Meia-Idade , Estudos Prospectivos , Qualidade de Vida , Satisfação do Paciente , Perda do Osso Alveolar , Adulto , Interações Hidrofóbicas e Hidrofílicas , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante
20.
Semin Arthritis Rheum ; 67: 152475, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38810568

RESUMO

OBJECTIVE: Antineutrophil cytoplasmic antibody (ANCA)-associated vasculitis (AAV) primarily affects small vessels. Large-vessel involvement (LVI) is rare. We aimed to describe the characteristics of LVI, to identify associated risk factors, and to describe its therapeutic management. METHODS: This multicenter case-control (1:2) study included patients with AAV according to the ACR/EULAR classification and LVI as defined by the Chapel Hill nomenclature, together with controls matched for age, sex, and AAV type. RESULTS: We included 26 patients, 15 (58 %) of whom were men, with a mean age of 56.0 ± 17.1 years. The patients had granulomatosis with polyangiitis (n = 20), or microscopic polyangiitis (n = 6). The affected vessels included the aorta (n = 18; 69 %) supra-aortic trunks (n = 9; 35 %), lower-limb arteries (n = 5; 19 %), mesenteric arteries (n = 5; 19 %), renal arteries (n = 4; 15 %), and upper-limb arteries (n = 2; 8 %). Imaging showed wall thickening (n = 10; 38 %), perivascular inflammation (n = 8; 31 %), aneurysms (n = 5; 19 %), and stenosis (n = 4; 15 %). Comparisons with the control group revealed that LVI was significantly associated with neurological manifestations (OR=3.23 [95 % CI: 1.11-10.01, p = 0.03]), but not with cardiovascular risk factors (OR=0.70 [95 % CI: 0.23-2.21, p = 0.60]), or AAV relapse (OR=2.01 [95 % CI: 0.70-5.88, p = 0.16]). All patients received corticosteroids, in combination with an immunosuppressant in 24 (92 %), mostly cyclophosphamide (n = 10, 38 %) or rituximab (n = 9, 35 %). CONCLUSION: Regardless of distinctions based on vessel size, clinicians should consider LVI as a potential manifestation of AAV, with the aorta commonly affected. The risk of developing LVI appears to be greater for clinical phenotypes of AAV with neurological involvement. Standard AAV treatment can be used to manage LVI.


Assuntos
Vasculite Associada a Anticorpo Anticitoplasma de Neutrófilos , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Vasculite Associada a Anticorpo Anticitoplasma de Neutrófilos/complicações , Estudos de Casos e Controles , Idoso , Adulto , Fatores de Risco , Imunossupressores/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...