Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Chem Lab Med ; 48(3): 413-8, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20001852

RESUMO

BACKGROUND: Detection and quantitation of Epstein-Barr virus (EBV) DNA in EDTA whole blood samples has gained significance in the routine diagnostic laboratory. METHODS: In this study, the analytical and clinical performance of the artus EBV RG PCR kit in conjunction with automated sample preparation on the QIAsymphony SP instrument was evaluated. RESULTS: When the accuracy of the new test system was tested, all results were found to be within +/-0.5 log(10) unit of the expected panel results. Determination of linearity showed a quasilinear curve over 4 log units. The lower limit of detection was determined to be 391 EBV DNA copies/mL in EDTA whole blood. The between day imprecision ranged from 18% to 66%, and the within run imprecision ranged from 11% to 50%. When clinical samples were tested and the results compared with those obtained with the routinely used easyMAG sample preparation and EBV R-gene test system, 60 samples tested positive and 31 samples tested negative by both assays. Nineteen samples were found to be positive using the QIAsymphony sample preparation and artus EBV RG PCR test system only, and no samples tested positive with the routinely used test system only. CONCLUSIONS: The QIAsymphony sample preparation and artus EBV RG PCR test system is suitable for the detection and quantitation of EBV DNA in EDTA whole blood in the routine diagnostic laboratory.


Assuntos
DNA Viral/sangue , Ácido Edético/química , Herpesvirus Humano 4/isolamento & purificação , Reação em Cadeia da Polimerase/métodos , Automação , Infecções por Vírus Epstein-Barr/diagnóstico , Herpesvirus Humano 4/genética , Humanos , Kit de Reagentes para Diagnóstico , Reprodutibilidade dos Testes
2.
J Med Virol ; 80(9): 1684-8, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18649328

RESUMO

Oral fluid has been used widely as sample matrix for the detection and quantitation of viral nucleic acids. However, in the vast majority of previous studies, various methods for collection of oral fluid and molecular assays lacking automation and standardization were used. In this study, a new standardized liquid phase-based saliva collection system was employed followed by a fully automated viral nucleic acid extraction and real-time PCR using commercially available in vitro diagnostics (IVD)/Conformité Européene (CE) labeled molecular assays. When the lower limit of detection of herpes simplex virus (HSV)-1/2 DNA, varicella zoster virus (VZV) DNA, and hepatitis C virus (HCV) RNA in spiked oral fluid was tested, the results were found to be comparable to those with defined sample materials recommended by the assay manufacturers. When clinical specimens were investigated, 21 of 25 (84%) oral fluids obtained from patients with clinically apparent herpetic lesions tested positive for HSV DNA, 7 of 10 (70%) oral fluids obtained from patients with Ramsay Hunt Syndrome tested positive for VZV DNA, and 19 of 40 (48%) oral fluids collected from patients with chronic HCV infection tested positive for HCV RNA. The automated extraction instruments completed all extractions without malfunction and no inhibitions were observed throughout the entire study. Liquid phase-based saliva collection in conjunction with automated and standardized commercially available molecular assays allows reliable quantitation of viral nucleic acids in oral fluid samples and may contribute to improved comparable and interpretable test results.


Assuntos
Automação/normas , DNA Viral/isolamento & purificação , RNA Viral/isolamento & purificação , Saliva/virologia , Virologia/métodos , Vírus/isolamento & purificação , DNA Viral/genética , Hepacivirus/genética , Hepacivirus/isolamento & purificação , Herpesvirus Humano 3/genética , Herpesvirus Humano 3/isolamento & purificação , Humanos , Reação em Cadeia da Polimerase , RNA Viral/genética , Sensibilidade e Especificidade , Simplexvirus/genética , Simplexvirus/isolamento & purificação , Vírus/genética
3.
J Clin Microbiol ; 46(4): 1241-5, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18272703

RESUMO

Whole blood has been found to be a reliable matrix for the detection and quantitation of cytomegalovirus (CMV) DNA. In this study, the performance of the artus CMV LightCycler (LC) PCR kit in conjunction with automated sample preparation on a BioRobot EZ1 workstation was evaluated. The accuracy, linearity, analytical sensitivity, and inter- and intra-assay variations were determined. A total of 102 clinical EDTA whole-blood samples were investigated, and results were compared with those obtained with the in vitro diagnostics (IVD)/Conformité Européene (CE)-labeled CMV HHV6,7,8 R-gene quantification kit. When the accuracy of the new kit was tested, seven of eight results were found to be within +/-0.5 log(10) unit of the expected panel results. Determination of linearity resulted in a quasilinear curve over more than 5 log units. The lower limit of detection of the assay was determined to be 139 copies/ml in EDTA whole blood. The interassay variation ranged from 15 to 58%, and the intra-assay variation ranged from 7 to 35%. When clinical samples were tested and the results were compared with those of the routinely used IVD/CE-labeled assay, 53 samples tested positive and 13 samples tested negative by both of the assays. One sample was found to be positive with the artus CMV LC PCR kit only, and 35 samples tested positive with the routinely used assay only. The majority of discrepant results were found with low-titer samples. In conclusion, use of the artus CMV LC PCR kit in conjunction with automated sample preparation on the BioRobot EZ1 workstation may be suitable for the detection and quantitation of CMV DNA in EDTA whole blood in the routine low-throughput laboratory; however, low-positive results may be missed by this assay.


Assuntos
Infecções por Citomegalovirus/virologia , Citomegalovirus/isolamento & purificação , DNA Viral/sangue , Reação em Cadeia da Polimerase/instrumentação , Reação em Cadeia da Polimerase/métodos , Kit de Reagentes para Diagnóstico , Anticoagulantes , Automação , Citomegalovirus/genética , Ácido Edético , Humanos , Reprodutibilidade dos Testes
4.
J Clin Virol ; 38(2): 96-100, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17185031

RESUMO

BACKGROUND: The Abbott RealTime HCV assay for quantitative detection of HCV RNA has recently been introduced. OBJECTIVES: In this study, the performance of the Abbott RealTime HCV assay was evaluated and compared to the COBAS AmpliPrep/COBAS TaqMan HCV test. STUDY DESIGN: Accuracy, linearity, interassay and intra-assay variations were determined, and a total of 243 routine clinical samples were investigated. RESULTS: When accuracy of the new assay was tested, the majority of results were found to be within +/-0.5 log(10) unit of the results obtained by reference laboratories. Determination of linearity resulted in a quasilinear curve up to 1.0 x 10(6)IU/ml. The interassay variation ranged from 15% to 32%, and the intra-assay variation ranged from 5% to 8%. When clinical samples were tested by the Abbott RealTime HCV assay and the results were compared with those obtained by the COBAS AmpliPrep/COBAS TaqMan HCV test, the results for 93% of all samples with positive results by both tests were found to be within +/-1.0 log(10) unit. The viral loads for all patients measured by the Abbott and Roche assays showed a high correlation (R(2)=0.93); quantitative results obtained by the Abbott assay were found to be lower than those obtained by the Roche assay. CONCLUSIONS: The Abbott RealTime HCV assay proved to be suitable for use in the routine diagnostic laboratory. The time to results was similar for both of the assays.


Assuntos
Hepacivirus/genética , Hepatite C/virologia , Reação em Cadeia da Polimerase/métodos , RNA Viral/análise , Humanos , RNA Viral/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...