Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Prosthodont ; 19(5): 374-80, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20202103

RESUMO

PURPOSE: To evaluate the effects of the elapsed time (ET) after nonvital bleaching (NVB) and sodium ascorbate application (10%) (SAA) on the shear bond strength of dentin to ceramic. MATERIALS AND METHODS: Bovine incisors were selected, internally bleached (35% carbamide peroxide) for 9 days and submitted to the following treatments (n = 10): G1, G2, G3-luting after 1, 7, and 14 days; G4, G5, and G6-luting after SAA, 1, 7, and 14 days, respectively. G7 and G8 were not bleached: G7-luting 24 hours after access cavity sealing; G8-luting 24 hours after access cavity sealing after SAA. After NVB, the vestibular dentin was exposed and flattened. The SAA was applied to the dentin (G4, G5, G6, G8) for 10 minutes, and it was then washed and dried. The dentin was etched (37% phosphoric acid), and an adhesive system (Single Bond 2) was applied. Feldspathic ceramic discs (VM7; 4-mm diameter, 3-mm thick) were luted with a dual-resin agent (RelyX ARC, 3M ESPE Dental Products, St. Paul, MN). After 24 hours, specimens were submitted to shear test on a universal testing machine. The data (MPa) were submitted to ANOVA and Dunnet's test (5%). RESULTS: The means (+/- SD) obtained were (MPa): G1 (14 +/- 4.5), G2 (14.6 +/- 3.1), G3 (14 +/- 3.7), G4 (15.5 +/- 4.6), G5 (19.87 +/- 4.5), G6 (16.5 +/- 3.7), G7 (22.8 +/- 6.2), and G8 (18.9 +/- 5.4). SAA had a significant effect on bond strength (p= 0.0054). The effect of ET was not significant (p= 0.1519). G5 and G6 presented higher values than the other bleached groups (p < 0.05) and similar to G7 and G8 (p > 0.05). CONCLUSIONS: After NVB, adhesive luting to dentin is recommended after 7 days if sodium ascorbate has been applied prior to dentin hybridization.


Assuntos
Antioxidantes/química , Ácido Ascórbico/química , Cimentação/métodos , Colagem Dentária , Porcelana Dentária/química , Dentina/ultraestrutura , Clareamento Dental/métodos , Condicionamento Ácido do Dente/métodos , Adesividade , Silicatos de Alumínio/química , Animais , Bis-Fenol A-Glicidil Metacrilato/química , Peróxido de Carbamida , Bovinos , Cimentos Dentários/química , Cavidade Pulpar/ultraestrutura , Adesivos Dentinários/química , Ácido Fluorídrico/química , Teste de Materiais , Oxidantes/química , Peróxidos/química , Ácidos Fosfóricos/química , Polietilenoglicóis/química , Ácidos Polimetacrílicos/química , Compostos de Potássio/química , Distribuição Aleatória , Cimentos de Resina/química , Resistência ao Cisalhamento , Estresse Mecânico , Fatores de Tempo , Dente não Vital/patologia , Ureia/análogos & derivados , Ureia/química
2.
J Prosthodont ; 19(3): 218-25, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20040031

RESUMO

PURPOSE: This study evaluated the degree of conversion (DC) of four indirect resin composites (IRCs) with various compositions processed in different polymerization units and investigated the effect of thermal aging on the flexural strength and Vicker's microhardness. MATERIALS AND METHODS: Specimens were prepared from four IRC materials, namely Gr 1: Resilab (Wilcos); Gr2: Sinfony (3M ESPE); Gr3: VITA VMLC (VITA Zahnfabrik); Gr4: VITA Zeta (VITA Zahnfabrik) using special molds for flexural strength test (N = 80, n = 10 per group) (25 x 2 x 2 mm(3), ISO 4049), for Vicker's microhardness test (N = 80, n = 10 per group) (5 x 4 mm(2)) and for DC (N = 10) using FT-Raman Spectroscopy. For both flexural strength and microhardness tests, half of the specimens were randomly stored in distilled water at 37 degrees C for 24 hours (Groups 1 to 4), and the other half (Groups 5 to 8) were subjected to thermocycling (5000 cycles, 5 to 55 +/- 1 degree C, dwell time: 30 seconds). Flexural strength was measured in a universal testing machine (crosshead speed: 0.8 mm/min). Microhardness test was performed at 50 g. The data were analyzed using one-way and two-way ANOVA and Tukey's test (alpha= 0.05). The correlation between flexural strength and microhardness was evaluated with Pearson's correlation test (alpha= 0.05). RESULTS: A significant effect for the type of IRC and thermocycling was found (p= 0.001, p= 0.001) on the flexural strength results, but thermocycling did not significantly affect the microhardness results (p= 0.078). The interaction factors were significant for both flexural strength and microhardness parameters (p= 0.001 and 0.002, respectively). Thermocycling decreased the flexural strength of the three IRCs tested significantly (p < 0.05), except for VITA Zeta (106.3 +/- 9.1 to 97.2 +/- 14 MPa) (p > 0.05) when compared with nonthermocycled groups. Microhardness results of only Sinfony were significantly affected by thermocycling (25.1 +/- 2.1 to 31 +/- 3.3 Kg/mm(2)). DC values ranged between 63% and 81%, and were not significantly different between the IRCs (p > 0.05). While a positive correlation was found between flexural strength and microhardness without (r = 0.309) and with thermocycling (r = 0.100) for VITA VMLC, negative correlations were found for Resilab under the same conditions (r =-0.190 and -0.305, respectively) (Pearson's correlation coefficient). CONCLUSION: Although all four IRCs presented nonsignificant DC values, flexural strength and microhardness values varied between materials with and without thermocycling.


Assuntos
Resinas Compostas/química , Materiais Dentários/química , Silicatos de Alumínio/química , Bis-Fenol A-Glicidil Metacrilato/química , Fenômenos Químicos , Análise do Estresse Dentário/instrumentação , Dureza , Humanos , Teste de Materiais , Metacrilatos/química , Maleabilidade , Polietilenoglicóis/química , Polímeros/química , Ácidos Polimetacrílicos/química , Poliuretanos/química , Dióxido de Silício/química , Espectroscopia de Infravermelho com Transformada de Fourier , Análise Espectral Raman , Estresse Mecânico , Temperatura , Fatores de Tempo
3.
J Prosthodont ; 19(2): 103-11, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20040035

RESUMO

PURPOSE: To evaluate the influence of surface treatment on the shear bond strength between a Co-Cr alloy and two ceramics. MATERIALS AND METHODS: Forty-eight metal cylinders were made (thickness: 4 mm, height: 3.7 mm) according ISO TR 11405. The 48 metallic cylinders were divided into four groups (n = 12), according to the veneering ceramic (StarLight Ceram and Duceram Kiss) and surface treatments: air-particle abrasion with Al(2)O(3) or tungsten drill (W). Gr1: StarLight + Al(2)O(3); Gr2: StarLight + W; Gr3: Duceram + Al(2)O(3); and Gr4: Duceram + W. The specimens were aged using thermal cycling (3000x, 5 to 55 degrees C, dwell time: 30 seconds, transfer time: 2 seconds). The shear test was performed with a universal testing machine, using a load cell of 100 kg (speed: 0.5 mm/min) and a specific device. The bond strength data were analyzed using ANOVA and Tukey's test (5%), and the failure modes were analyzed using an optical microscope (30x). RESULTS: The means and standard deviations of the shear bond strengths were (MPa): G1 (57.97 +/- 11.34); G2 (40.62 +/- 12.96); G3 (47.09 +/- 13.19); and G4 (36.80 +/- 8.86). Ceramic (p= 0.03252) and surface treatment (p= 0.0002) significantly affected the mean bond strength values. CONCLUSIONS: Air-particle abrasion with Al(2)O(3) improved the shear bond strength between metal and ceramics used.


Assuntos
Abrasão Dental por Ar , Ligas de Cromo , Colagem Dentária , Porcelana Dentária , Ligas Metalo-Cerâmicas , Análise de Variância , Cobalto , Análise do Estresse Dentário , Teste de Materiais , Microscopia Eletrônica de Varredura , Resistência ao Cisalhamento , Estatísticas não Paramétricas , Propriedades de Superfície
4.
J Contemp Dent Pract ; 9(4): 34-42, 2008 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-18473025

RESUMO

AIM: Based on the hypothesis the application of a low-viscosity hydrophobic resin coating improves the bond of all-in-one adhesive, the purpose of the study was to evaluate the bond strength of four adhesive systems to bovine root dentin using the push-out test method. METHODS AND MATERIALS: The root canals of 32 bovine roots (16 mm) were prepared to a length of 12 mm using a FRC Postec Plus preparation drill. The specimens were allocated into four groups according to the adhesive system used: (Group 1) All-in-one Xeno III; (Group 2) All-in-one Xeno III+ScotchBond Multi-Purpose Plus Adhesive; (Group 3) Simplified Etch & Rinse One Step Plus; and (Group 4) Multi-Bottle Etch & Rinse All-Bond 2. A fiber-reinforced composite retention post was reproduced using an additional silicon impression and fabricated with DuoLink resin cement. The root specimens were treated with the selected adhesive systems, and the resin posts were luted in the canals with DuoLink resin cement. Each root specimen was cross sectioned into four samples (+/-1.8 mm in thickness), and the post sections were pushed-out to determine the bond strength to dentin. RESULTS: Group 2 (2.9+/-1.2) was statistically higher than Group 1 (1.1+/-0.5) and Group 3 (1.1+/-0.5). Groups 1 and 3 showed no statistically significant difference while Group 4 (2.0+/-0.7) presented similar values (p>0.05) to Groups 1, 2, and 3 [(one-way analysis of variance (ANOVA)] and Tukey test, a=0.05). CONCLUSION: The hypothesis was accepted since the application of the additional layer of a low-viscosity bonding resin improved the bond of the all-in-one adhesive. Further studies must be conducted to evaluate the long-term bond.


Assuntos
Resinas Compostas/química , Colagem Dentária , Cavidade Pulpar/ultraestrutura , Adesivos Dentinários/química , Dentina/ultraestrutura , Cimentos de Resina/química , Condicionamento Ácido do Dente/métodos , Adesividade , Animais , Bovinos , Interações Hidrofóbicas e Hidrofílicas , Teste de Materiais , Metacrilatos/química , Técnica para Retentor Intrarradicular/instrumentação , Preparo de Canal Radicular/métodos , Estresse Mecânico
5.
J Adhes Dent ; 9(6): 521-6, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18265709

RESUMO

PURPOSE: To evaluate the influence of the brush type as a carrier of priming adhesive solutions and the use of paper points as a remover of the excess of these solutions on the push-out bond strength of resin cement to bovine root dentin. The null hypotheses were that brush type and the use of paper points do not affect the bond strength. MATERIALS AND METHODS: The canals of 80 single-root bovine roots (16 mm in length) were prepared at 12 mm using the preparation drill (FRC Postec Plus, Ivoclar). Half of each root was embedded in acrylic resin and the specimens were divided into 8 groups, considering the factors "brush type" (4 levels) and "paper point" (2 levels) (n = 10): Gr 1: small microbrush (Cavi-Tip, SDI); Gr 2: Microbrush (Dentsply); Gr 3: Endobrush (Bisco); Gr 4: conventional brush (Bisco); Gr 5: Cavi-Tip (SDI) + paper points; Gr 6: Microbrush (Dentsply) + paper points; Gr 7: Endobrush (Bisco) + paper points; Gr 8: conventional brush (Bisco) + paper points. The root dentin was treated with a multistep total-etch adhesive system (All Bond 2). The adhesive system was applied using each microbrush, with and without using paper points. One fiber post was molded with addition silicon and 80 posts were made of resin cement (Duolink). The resin posts were luted (Duolink resin cement), and the specimens were stored for 24 h in water at 37 degrees C. Each specimen was cut into 4 disk-shaped samples (1.8 mm in thickness), which were submitted to the push-out test. RESULTS: The brush type (p < 0.0001) (small microbrush > microbrush = endobrush = conventional brush) and the use of paper points (p = 0.0001) (with > without) influenced the bond strength significantly (two-way ANOVA). The null hypotheses were rejected. CONCLUSION: The smallest brush (Cavi-Tip) and the use of paper points significantly improved the resin bond to bovine root dentin.


Assuntos
Colagem Dentária/instrumentação , Cavidade Pulpar/ultraestrutura , Adesivos Dentinários/química , Dentina/ultraestrutura , Papel , Cimentos de Resina/química , Condicionamento Ácido do Dente/métodos , Animais , Bovinos , Colagem Dentária/métodos , Desenho de Equipamento , Teste de Materiais , Metacrilatos/química , Microscopia Eletrônica de Varredura , Técnica para Retentor Intrarradicular/instrumentação , Preparo de Canal Radicular/instrumentação , Silicones/química , Estresse Mecânico , Propriedades de Superfície , Temperatura , Fatores de Tempo , Água/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...