Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Allergy ; 77(11): 3362-3376, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35778780

RESUMO

BACKGROUND: In T2-mediated severe asthma, biologic therapies, such as mepolizumab, are increasingly used to control disease. Current biomarkers can indicate adequate suppression of T2 inflammation, but it is unclear whether they provide information about airway microbial composition. We investigated the relationships between current T2 biomarkers and microbial profiles, characteristics associated with a ProteobacteriaHIGH microbial profile and the effects of mepolizumab on airway ecology. METHODS: Microbiota sequencing was performed on sputum samples obtained at stable and exacerbation state from 140 subjects with severe asthma participating in two clinical trials. Inflammatory subgroups were compared on the basis of biomarkers, including FeNO and sputum and blood eosinophils. ProteobacteriaHIGH subjects were identified by Proteobacteria to Firmicutes ratio ≥0.485. Where paired sputum from stable visits was available, we compared microbial composition at baseline and following ≥12 weeks of mepolizumab. RESULTS: Microbial composition was not related to inflammatory subgroup based on sputum or blood eosinophils. FeNO ≥50 ppb when stable and at exacerbation indicated a group with less dispersed microbial profiles characterised by high alpha-diversity and low Proteobacteria. ProteobacteriaHIGH subjects were neutrophilic and had a longer time from asthma diagnosis than ProteobacteriaLOW subjects. In those studied, mepolizumab did not alter airway bacterial load or lead to increased Proteobacteria. CONCLUSION: High FeNO could indicate a subgroup of severe asthma less likely to benefit from antimicrobial strategies at exacerbation or in the context of poor control. Where FeNO is <50 ppb, biomarkers of microbial composition are required to identify those likely to respond to microbiome-directed strategies. We found no evidence that mepolizumab alters airway microbial composition.


Assuntos
Asma , Humanos , Asma/diagnóstico , Asma/tratamento farmacológico , Asma/microbiologia , Eosinófilos , Escarro/microbiologia , Sistema Respiratório/microbiologia , Biomarcadores
2.
Lancet Respir Med ; 10(5): 469-477, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35339234

RESUMO

BACKGROUND: Chronic obstructive pulmonary disease (COPD) is a heterogeneous inflammatory airway disease. The epithelial-derived IL-33 and its receptor ST2 have been implicated in airway inflammation and infection. We aimed to determine whether astegolimab, a selective ST2 IgG2 monoclonal antibody, reduces exacerbations in COPD. METHODS: COPD-ST2OP was a single-centre, randomised, double-blinded, placebo-controlled phase 2a trial in moderate-to-very severe COPD. Participants were randomly assigned (1:1) with a web-based system to received 490 mg subcutaneous astegolimab or subcutaneous placebo, every 4 weeks for 44 weeks. The primary endpoint was exacerbation rate assessed for 48 weeks assessed with a negative binomial count model in the intention-to-treat population, with prespecified subgroup analysis by baseline blood eosinophil count. The model was the number of exacerbations over the 48-week treatment period, with treatment group as a covariate. Safety was assessed in the whole study population until week 60. Secondary endpoints included Saint George's Respiratory Questionnaire for COPD (SGRQ-C), FEV1, and blood and sputum cell counts. The trial was registered with ClinicalTrials.gov, NCT03615040. FINDINGS: The exacerbation rate at 48 weeks in the intention-to-treat analysis was not significantly different between the astegolimab group (2·18 [95% CI 1·59 to 2·78]) and the placebo group (2·81 [2·05 to 3·58]; rate ratio 0·78 [95% CI 0·53 to 1·14]; p=0·19]). In the prespecified analysis stratifying patients by blood eosinophil count, patients with 170 or fewer cells per µL had 0·69 exacerbations (0·39 to 1·21), whereas those with more than 170 cells per µL had 0·83 exacerbations (0·49 to 1·40). For the secondary outcomes, the mean difference between the SGRQ-C in the astegolimab group versus placebo group was -3·3 (95% CI -6·4 to -0·2; p=0·039), and mean difference in FEV1 between the two groups was 40 mL (-10 to 90; p=0·094). The difference in geometric mean ratios between the two groups for blood eosinophil counts was 0·59 (95% CI 0·51 to 0·69; p<0·001) and 0·25 (0·19 to 0·33; p<0·001) for sputum eosinophil counts. Incidence of treatment-emergent adverse events was similar between groups. INTERPRETATION: In patients with moderate-to-very severe COPD, astegolimab did not significantly reduce exacerbation rate, but did improve health status compared with placebo. FUNDING: Funded by Genentech and National Institute for Health Research Biomedical Research Centres.


Assuntos
Proteína 1 Semelhante a Receptor de Interleucina-1 , Doença Pulmonar Obstrutiva Crônica , Anticorpos Monoclonais Humanizados/uso terapêutico , Progressão da Doença , Método Duplo-Cego , Eosinófilos , Humanos , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...