2.
Z Kardiol ; 82 Suppl 2: 35-40, 1993.
Artigo em Alemão | MEDLINE | ID: mdl-8328208

RESUMO

The long-term results of 222 patients (pts) with transvenously implanted vena cava filters are critically reviewed. A total of 98 pts were given a Mobin-Uddin filter, 102 pts a Günther filter, and 16 pts a LGM filter. Among the serious complications observed during long-term follow-up were vena cava occlusions and increasing symptoms ranging from congestion of the deep leg veins, perforations into ureters, fractures and embolizations of the filters in up to 40% of the patients, if Günther filters were implanted.


Assuntos
Embolia Pulmonar/prevenção & controle , Filtros de Veia Cava , Desenho de Equipamento , Falha de Equipamento , Seguimentos , Humanos , Flebografia , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/mortalidade , Recidiva
4.
Z Urol Nephrol ; 80(12): 695-7, 1987 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-2964765

RESUMO

Report on the successful therapy of an erectile impotence by percutaneous transluminal angioplasty of the internal iliac artery in a patient with arterial obliteration.


Assuntos
Angioplastia com Balão , Artéria Ilíaca , Isquemia/terapia , Perna (Membro)/irrigação sanguínea , Arteriosclerose/terapia , Humanos , Claudicação Intermitente/terapia , Masculino , Pessoa de Meia-Idade