Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 404
Filtrar
1.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-39059729

RESUMO

INTRODUCTION AND OBJECTIVES: Only about 1 out of every 3 patients with acute myocardial infarction (AMI) achieve low-density lipoprotein cholesterol (LDL-C) values < 55 mg/dL in the first year. The present study aims to evaluate the impact of early intensive therapy on lipid control after an AMI. METHODS: An independent, prospective, pragmatic, controlled, randomized, open-label, evaluator-blinded clinical trial (PROBE design) will analyze the efficacy and safety of an oral lipid-lowering triple therapy: high-potency statin + bempedoic acid (BA) 180 mg + ezetimibe (EZ) 10 mg versus current European-based guidelines (high-potency statin ± EZ 10 mg), in AMI patients. LDL-C will be determined within the first 48 hours. Patients with LDL-C ≥ 115 mg/dL (without previous statin therapy), ≥ 100 mg/dL (with previous low-potency or high-potency statin therapy at submaximal dose), or ≥ 70 mg/dL (with previous high-potency statin therapy at high dose) will be randomly assigned 1:1 between 24 and 72 hours post-AMI to the BA/EZ combination or to statin ± EZ, without BA. The primary endpoint is the proportion of patients reaching LDL-C < 55 mg/dL at 8 weeks after treatment. RESULTS: The results of this study will provide novel information for post-AMI LDL-C control by evaluating the usefulness of an early intensive lipid-lowering strategy based on triple oral therapy. CONCLUSIONS: Early intensive lipid-lowering triple oral therapy vs the treatment recommended by current clinical practice guidelines could facilitate the achievement of optimal LDL-C levels in the first 2 months after AMI (a high-risk period). Identification number EudraCT 2021-006550-31.

2.
Dental Press J Orthod ; 29(2): e2423212, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38865514

RESUMO

OBJECTIVE: The purpose of this retrospective study was to compare accuracy of arch expansion using two different thermoplastic materials in Invisalign aligners: EX30® (Polyethylene Terephthalate Glycol, or PETG) and SmartTrack® (polyurethane). METHODS: The study sample comprised 65 adult patients consecutively treated with Invisalign from two private practices: group 1 - treated with EX30® (358 teeth) and group 2 - treated with SmartTrack® (888 teeth). Six hundred and twenty-three measurements were assessed in three digital models throughout treatment: model 1 - initial, model 2 - predicted tooth position, and model 3 - achieved position. Sixteen reference points per arch were marked and, after best alignment, 2 points per tooth were copied from one digital model to another. Linear values of both arches were measured for canines, premolars, and first molars: on lingual gingival margins and cusp tips of every tooth. Comparisons were performed by Wilcoxon and Mann-Whitney test. RESULTS: Both termoplastic materials presented significant differences between predicted and achieved values for all measurements, except for the lower molar cusp tip in the SmartTrack® group. There is no statistical difference in the accuracy of transverse expansion between these two materials. Overall accuracy for EX30® aligners in maxilla and mandible were found to be 37 and 38%, respectively; and Smarttrack® presented an overall accuracy of 56.62% in the maxilla and 68.72% in the mandible. CONCLUSIONS: It is not possible to affirm one material expands better than the other. Further controlled clinical studies should be conducted comparing SmartTrack® and EX30® under similar conditions.


Assuntos
Desenho de Aparelho Ortodôntico , Polietilenotereftalatos , Poliuretanos , Técnicas de Movimentação Dentária , Humanos , Estudos Retrospectivos , Adulto , Feminino , Técnicas de Movimentação Dentária/instrumentação , Masculino , Poliuretanos/uso terapêutico , Polietilenoglicóis , Arco Dental , Aparelhos Ortodônticos Removíveis , Adulto Jovem
3.
Einstein (Sao Paulo) ; 22: eAE0780, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38865568

RESUMO

Implementing a structured COVID-19 lung ultrasound system, using COVID-RADS standardization. This case series exams revealed correlations between ultrasonographic and tomographic findings. Ventilatory assessments showed that higher categories required second-line oxygen. This replicable tool will aid in screening and predicting disease severity beyond the pandemic. OBJECTIVE: We aimed to share our experience in implementing a structured system for COVID-19 lung findings, elucidating key aspects of the lung ultrasound score to facilitate its standardized clinical use beyond the pandemic scenario. METHODS: Using a scoring system to classify the extent of lung involvement, we retrospectively analyzed the ultrasound reports performed in our institution according to COVID-RADS standardization. RESULTS: The study included 69 thoracic ultrasound exams, with 27 following the protocol. The majority of patients were female (52%), with ages ranging from 1 to 96 years and an average of 56 years. Classification according to COVID-RADS was as follows: 11.1% in category 0, 37% in category 1, 44.4% in category 2, and 7.4% in category 3. Ground-glass opacities on tomography correlated with higher COVID-RADS scores (categories 2 and 3) in 82% of cases. Ventilatory assessment revealed that 50% of cases in higher COVID-RADS categories (2 and 3) required second-line oxygen supplementation, while none of the cases in lower categories (0 and 1) utilized this support. CONCLUSION: Lung ultrasound has been widely utilized as a diagnostic tool owing to its availability and simplicity of application. In the context of the pandemic emergency, a pressing need for a focused and easily applicable assessment arose. The structured reporting system, incorporating ultrasound findings for stratification, demonstrated ease of replicability. This system stands as a crucial tool for screening, predicting severity, and aiding in medical decisions, even in a non-pandemic context. Lung ultrasound enables precise diagnosis and ongoing monitoring of the disease. Ultrasound is an effective tool for assessing pulmonary findings in COVID-19. Structured reports enhance communication and are easily reproducible.


Assuntos
COVID-19 , Pulmão , Ultrassonografia , Humanos , COVID-19/diagnóstico por imagem , Feminino , Ultrassonografia/métodos , Masculino , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso , Criança , Adolescente , Adulto , Pulmão/diagnóstico por imagem , Idoso de 80 Anos ou mais , Adulto Jovem , Lactente , Pré-Escolar , Pandemias , SARS-CoV-2 , Tomografia Computadorizada por Raios X/métodos , Índice de Gravidade de Doença
4.
Animals (Basel) ; 14(9)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38731376

RESUMO

This study evaluated the effects of dietary supplementation in dairy cows with two Se forms (organic and inorganic) and I at the maximum levels permitted in the European Union, with the aim to obtain naturally enriched milk and derived products. A total of 20 Holstein Friesian cows in lactation were fed 2 diets for 64 days: a control diet with a supply of 0.57 mg of inorganic Se and 0.57 mg of I per kg of ration in dry matter (DM), and an experimental diet (SeI) with a supply of 0.34 mg of inorganic Se, 0.23 mg of organic Se, and 5.68 mg of I per kg of ration in DM. The SeI diet did not modify the performance or, in general, the metabolic profile of cows. Se and I levels in milk were affected by diet type and time of measurement (p < 0.01). Thus, a marked increase of both microminerals was evident between the beginning and the end of the test, when the SeI diet was administered. For Se, this increase ranged from 1.95 to 3.29 µg/100 g of milk; and for I, from 19.69 to 110.06 µg/100 g of milk. The SeI diet increased (p < 0.01) the Se and I content in the cheese, reaching levels of 16.4 µg/100 g for Se and 269.7 µg/100 g for I. An increase in I was observed in yogurt from the SeI diet (p < 0.001). The supplementation of two forms of Se and I in the cows' ration, at the levels evaluated, produced milk and dairy products enriched in these microelements without altering their quality parameters. However, a responsible intake of these products is necessary to avoid risks of deficiencies or excesses that could negatively affect the health of consumers.

5.
Dental Press J Orthod ; 29(2): e2423237, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38775600

RESUMO

OBJECTIVE: This retrospective study aimed to assess the predictability of Invisalign® aligners regarding rotational, mesio-distal and buccal-lingual tip movements. METHODS: Two materials were included in the analysis - EX30, used until 2013; and SmartTrack, in current use. The study comprised 56 adult patients treated with Invisalign Comprehensive. Data sample were assessed on three sets of digital models; model 1 - initial, model 2 - predicted, and model 3 - achieved. Sixty reference points were marked in each dental arch, and two reference planes assisted the superimposition. The degree of rotation, mesio-distal and buccal-lingual tip was obtained via trigonometric calculations, through a previously published validated method. The accuracy of outcomes was compared according to the types of tooth movement and teeth groups,and the influence of predetermined variables on movement accuracy was also investigated. RESULTS: Rotation and mesio-distal tip did not present any significant difference when comparing EX30 and SmartTrack groups. Only buccal-lingual tip presented a significant difference, incisor and canine groups treated with EX30 aligners presented an increase in accuracy (p= 0.007 and p = 0.007, respectively). For each additional degree planned for rotation movements, there was an increase of 0.35° in the discrepancy, and an increase of 0.40° and 0.41° for mesio-distal and buccal-lingual tip, respectively. EX30 and SmartTrack discrepancies were compared by multilevel linear regression. CONCLUSION: EX30 aligners reached higher accuracy for buccal-lingual tip in anterior teeth. However, for rotation and mesio-distal tip, SmartTrack and EX30 are similarly accurate. The total amount of planned movement has a significant impact on accuracy rates, with a decrease in accuracy for every additional degree.


Assuntos
Técnicas de Movimentação Dentária , Humanos , Técnicas de Movimentação Dentária/instrumentação , Estudos Retrospectivos , Adulto , Rotação , Feminino , Masculino , Desenho de Aparelho Ortodôntico , Incisivo , Modelos Dentários , Aparelhos Ortodônticos Removíveis , Arco Dental
6.
BMC Bioinformatics ; 25(1): 200, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38802733

RESUMO

BACKGROUND: The initial version of SEDA assists life science researchers without programming skills with the preparation of DNA and protein sequence FASTA files for multiple bioinformatics applications. However, the initial version of SEDA lacks a command-line interface for more advanced users and does not allow the creation of automated analysis pipelines. RESULTS: The present paper discusses the updates of the new SEDA release, including the addition of a complete command-line interface, new functionalities like gene annotation, a framework for automated pipelines, and improved integration in Linux environments. CONCLUSION: SEDA is an open-source Java application and can be installed using the different distributions available ( https://www.sing-group.org/seda/download.html ) as well as through a Docker image ( https://hub.docker.com/r/pegi3s/seda ). It is released under a GPL-3.0 license, and its source code is publicly accessible on GitHub ( https://github.com/sing-group/seda ). The software version at the time of submission is archived at Zenodo (version v1.6.0, http://doi.org/10.5281/zenodo.10201605 ).


Assuntos
Biologia Computacional , Software , Biologia Computacional/métodos , Análise de Dados
7.
Genes (Basel) ; 15(4)2024 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-38674398

RESUMO

Human sperm parameters serve as a first step in diagnosing male infertility, but not in determining the potential for successful pregnancy during assisted reproductive technologies (ARTs) procedures. Here, we investigated the relationship between sperm head morphology at high magnification, based on strict morphologic criteria, and the nuclear architecture analyzed by fluorescence in situ hybridization (FISH). We included five men. Two of them had an elevated high-magnification morphology score of 6 points (Score 6) indicating high fertility potential, whereas three had a low score of 0 points (Score 0), indicating low fertility potential. We used FISH to study the inter-telomeric distance and the chromosomal territory area of chromosome 1 (Chr. 1). We then compared these two parameters between subjects with high and low scores. FISH data analysis showed that the inter-telomeric distance (ITD) and chromosomal territory area (CTA) of Chr. 1 were significantly higher in subjects with low scores (score 0) than high scores (score 6). Our results suggest that (i) there is a link between nuclear architecture and sperm head abnormalities, particularly vacuoles; and (ii) it is possible to select spermatozoa with normal nuclear architecture, which might indirectly explain the positive ART outcomes observed with this technique.


Assuntos
Núcleo Celular , Hibridização in Situ Fluorescente , Espermatozoides , Humanos , Masculino , Hibridização in Situ Fluorescente/métodos , Núcleo Celular/genética , Adulto , Cabeça do Espermatozoide , Infertilidade Masculina/genética , Infertilidade Masculina/patologia , Cromossomos Humanos Par 1/genética
8.
Hematol Rep ; 16(1): 140-150, 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38534885

RESUMO

BACKGROUND: Second- and third-generation tyrosine kinase inhibitors (TKIs) are now available to treat chronic-phase chronic myeloid leukemia (CP-CML) in the first and second line. However, vascular adverse events (VAEs) have been reported for patients with CML treated with some TKIs. METHODS: We retrospectively evaluated the cumulative incidence (CI) and cardiovascular risk for 210 patients included in the Canarian Registry of CML. RESULT: With a mean follow up of 6 years, 19/210 (9.1%) patients developed VAEs, all of whom presented at least one cardiovascular risk factor at diagnosis. The mean time to VAE presentation was 54 months from the start of TKI treatment. We found a statistically significant difference between the CI for nilotinib-naïve vs. nilotinib-treated patients (p = 0.005), between dasatinib-naïve and dasatinib-treated patients (p = 0.039), and for patients who received three lines of treatment with first-line imatinib vs. first-line imatinib (p < 0.001). From the multivariable logistic regression analyses, the Framingham risk score (FRS) and patients with three lines of TKI with first-line imatinib were the only variables with statistically significant hazard ratios for VAE development. Significant increases in HDL-C and total cholesterol may also be predictive for VAE. CONCLUSIONS: In conclusion, it is important to estimate the cardiovascular risk at the diagnosis of CML as it can help determine whether a patient is likely to develop a VAE during TKI treatment.

10.
JACC Cardiovasc Interv ; 17(6): 756-767, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38385926

RESUMO

BACKGROUND: Intravascular lithotripsy (IVL) has demonstrated effectiveness in the treatment of calcified lesions in selected patients with stable coronary disease. OBJECTIVES: The authors sought to assess the performance of coronary IVL in calcified coronary lesions in a real-life, all comers, setting. METHODS: The REPLICA-EPIC18 study prospectively enrolled consecutive patients treated with IVL in 26 centers in Spain. An independent core laboratory performed the angiographic analysis and event adjudication. The primary effectiveness endpoint assessed procedural success (successful IVL delivery, final diameter stenosis <20%, and absence of in-hospital major adverse cardiovascular events [MACE]). The primary safety endpoint measured freedom from MACE at 30 days. A predefined substudy compared outcomes between acute coronary syndrome (ACS) and chronic coronary syndrome (CCS) patients. RESULTS: A total of 426 patients (456 lesions) were included, 63% of the patients presenting with ACS. IVL delivery was successful in 99% of cases. Before IVL, 49% of lesions were considered undilatable. The primary effectiveness endpoint was achieved in 66% of patients, with similar rates among CCS patients (68%) and ACS patients (65%). Likewise, there were no significant differences in angiographic success after IVL between CCS and ACS patients. The rate of MACE at 30 days (primary safety endpoint) was 3% (1% in CCS and 5% in ACS patients [P = 0.073]). CONCLUSIONS: Coronary IVL proved to be a feasible and safe procedure in a "real-life" setting, effectively facilitating stent implantation in severely calcified lesions. Patients with ACS on admission showed similar angiographic success rates but showed a trend toward higher 30-day MACE compared with patients with CCS. (REPLICA-EPIC18 study [Registry of Coronary Lithotripsy in Spain]; NCT04298307).


Assuntos
Síndrome Coronariana Aguda , Doença da Artéria Coronariana , Litotripsia , Calcificação Vascular , Humanos , Vasos Coronários , Estudos Prospectivos , Resultado do Tratamento , Coração , Litotripsia/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/terapia
12.
Clin Res Cardiol ; 113(2): 223-234, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37368015

RESUMO

INTRODUCTION AND OBJECTIVES: Vaccines against SARS-CoV-2 have been a major scientific and medical achievement in the control of the COVID-19 pandemic. However, very infrequent cases of inflammatory heart disease have been described as adverse events, leading to uncertainty in the scientific community and in the general population. METHODS: The Vaccine-Carditis Registry has included all cases of myocarditis and pericarditis diagnosed within 30 days after COVID-19 vaccination since August 1, 2021 in 29 centers throughout the Spanish territory. The definitions of myocarditis (probable or confirmed) and pericarditis followed the consensus of the Centers for Disease Control and the Clinical Practice Guidelines of the European Society of Cardiology. A comprehensive analysis of clinical characteristics and 3-month evolution is presented. RESULTS: From August 1, 2021, to March 10, 2022, 139 cases of myocarditis or pericarditis were recorded (81.3% male, median age 28 years). Most cases were detected in the 1st week after administration of an mRNA vaccine, the majority after the second dose. The most common presentation was mixed inflammatory disease (myocarditis and pericarditis). 11% had left ventricular systolic dysfunction, 4% had right ventricular systolic dysfunction, and 21% had pericardial effusion. In cardiac magnetic resonance studies, left ventricular inferolateral involvement was the most frequent pattern (58%). More than 90% of cases had a benign clinical course. After a 3-month follow-up, the incidence of adverse events was 12.78% (1.44% mortality). CONCLUSIONS: In our setting, inflammatory heart disease after vaccination against SARS-CoV-2 predominantly affects young men in the 1st week after the second dose of RNA-m vaccine and presents a favorable clinical course in most cases.


Assuntos
Vacinas contra COVID-19 , COVID-19 , Miocardite , Pericardite , Adulto , Feminino , Humanos , Masculino , COVID-19/epidemiologia , COVID-19/prevenção & controle , Vacinas contra COVID-19/efeitos adversos , Progressão da Doença , Miocardite/induzido quimicamente , Miocardite/epidemiologia , Pericardite/induzido quimicamente , Pericardite/epidemiologia , Sistema de Registros , Vacinação/efeitos adversos , Espanha
13.
Dental press j. orthod. (Impr.) ; 29(2): e2423212, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1557692

RESUMO

ABSTRACT Objective: The purpose of this retrospective study was to compare accuracy of arch expansion using two different thermoplastic materials in Invisalign aligners: EX30® (Polyethylene Terephthalate Glycol, or PETG) and SmartTrack® (polyurethane). Methods: The study sample comprised 65 adult patients consecutively treated with Invisalign from two private practices: group 1 - treated with EX30® (358 teeth) and group 2 - treated with SmartTrack® (888 teeth). Six hundred and twenty-three measurements were assessed in three digital models throughout treatment: model 1 - initial, model 2 - predicted tooth position, and model 3 - achieved position. Sixteen reference points per arch were marked and, after best alignment, 2 points per tooth were copied from one digital model to another. Linear values of both arches were measured for canines, premolars, and first molars: on lingual gingival margins and cusp tips of every tooth. Comparisons were performed by Wilcoxon and Mann-Whitney test. Results: Both termoplastic materials presented significant differences between predicted and achieved values for all measurements, except for the lower molar cusp tip in the SmartTrack® group. There is no statistical difference in the accuracy of transverse expansion between these two materials. Overall accuracy for EX30® aligners in maxilla and mandible were found to be 37 and 38%, respectively; and Smarttrack® presented an overall accuracy of 56.62% in the maxilla and 68.72% in the mandible. Conclusions: It is not possible to affirm one material expands better than the other. Further controlled clinical studies should be conducted comparing SmartTrack® and EX30® under similar conditions.


RESUMO Objetivo: O objetivo deste estudo retrospectivo foi comparar a acurácia na expansão da arcada utilizando alinhadores Invisalign com dois tipos de material termoplástico: EX30® (Polietileno Tereftalato Glicol, ou PETG) e SmartTrack® (poliuretano). Método: A amostra desse estudo incluiu 65 pacientes adultos tratados consecutivamente em dois consultórios particulares: grupo 1 - tratado com EX30® (358 dentes), e grupo 2 - tratado com SmartTrack® (888 dentes). Foram avaliadas 623 medidas em três pares de modelos digitais, ao longo do tratamento: modelo 1 - inicial, modelo 2 - posição dentária planejada, modelo 3 - posição alcançada. Foram marcados 16 pontos de referência por arcada e, após o bestfit, 2 pontos por arcada foram copiados de um modelo digital para o outro. Medidas lineares de ambas as arcadas foram aferidas para caninos, pré-molares e primeiros molares, localizadas na margem gengival lingual e ponta de cúspide de todos os dentes. Foram realizadas comparações usando os testes Wilcoxon e Mann-Whitney. Resultados: Ambos os materiais termoplásticos apresentaram diferenças significativas entre os valores planejados e alcançados em todas as medidas, exceto na ponta de cúspide dos primeiros molares inferiores do grupo SmartTrack®. Não houve diferença estatística entre esses dois materiais quanto à acurácia da expansão transversa. Em termos gerais, a acurácia dos alinhadores EX30® na maxila e mandíbula foi de 37% e 38%, respectivamente. O grupo SmartTrack® apresentou acurácia de 56,62% e 68,72% na maxila e mandíbula, respectivamente. Conclusões: Não foi possível afirmar que um material expande melhor que o outro. Estudos clínicos controlados futuros devem ser conduzidos comparando SmartTrack® e EX30® sob condições similares.

14.
Dental press j. orthod. (Impr.) ; 29(2): e2423237, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1557693

RESUMO

ABSTRACT Objective: This retrospective study aimed to assess the predictability of Invisalign® aligners regarding rotational, mesio-distal and buccal-lingual tip movements. Methods: Two materials were included in the analysis - EX30, used until 2013; and SmartTrack, in current use. The study comprised 56 adult patients treated with Invisalign Comprehensive. Data sample were assessed on three sets of digital models; model 1 - initial, model 2 - predicted, and model 3 - achieved. Sixty reference points were marked in each dental arch, and two reference planes assisted the superimposition. The degree of rotation, mesio-distal and buccal-lingual tip was obtained via trigonometric calculations, through a previously published validated method. The accuracy of outcomes was compared according to the types of tooth movement and teeth groups,and the influence of predetermined variables on movement accuracy was also investigated. Results: Rotation and mesio-distal tip did not present any significant difference when comparing EX30 and SmartTrack groups. Only buccal-lingual tip presented a significant difference, incisor and canine groups treated with EX30 aligners presented an increase in accuracy (p= 0.007 and p = 0.007, respectively). For each additional degree planned for rotation movements, there was an increase of 0.35° in the discrepancy, and an increase of 0.40° and 0.41° for mesio-distal and buccal-lingual tip, respectively. EX30 and SmartTrack discrepancies were compared by multilevel linear regression. Conclusion: EX30 aligners reached higher accuracy for buccal-lingual tip in anterior teeth. However, for rotation and mesio-distal tip, SmartTrack and EX30 are similarly accurate. The total amount of planned movement has a significant impact on accuracy rates, with a decrease in accuracy for every additional degree.


RESUMO Objetivo: Esse estudo retrospectivo teve como objetivo aferir a previsibilidade dos alinhadores Invisalign em relação aos movimentos de rotação e inclinações mesiodistal e vestibulolingual. Material e Métodos: Foram incluídos dois materiais nessa análise: EX30®, utilizado até 2013; e SmartTrack®, atualmente em uso. Esse estudo avaliou 56 pacientes tratados com Invisalign Comprehensive. Os dados foram avaliados em três pares de modelos digitais; modelo 1 - inicial, modelo 2 - planejado, e modelo 3 - alcançado. Foram marcados 60 pontos de referência em cada arcada, sendo a sobreposição realizada com auxílio de planos de referência. O grau de rotação e inclinações mesiodistal e vestibulolingual foi obtido por cálculos de trigonometria, usando um método validado publicado anteriormente. Os resultados foram comparados de acordo com os tipos de movimento dentário e grupos de dentes, também foi investigada a influência de variáveis predeterminadas na confiabilidade dos movimentos. Resultados: Os movimentos de rotação e inclinação mesiodistal não apresentaram diferença estatística, quando comparados os grupos EX30® e SmartTrack®. Somente a inclinação vestibulolingual apresentou diferença estatisticamente significativa, sendo que os grupos de incisivos e caninos tratados com alinhadores EX30® apresentaram um aumento na previsibilidade(p= 0,007 e p= 0,007, respectivamente). Para cada grau adicional planejado para movimento de rotação, ocorreu um aumento de 0,35° na discrepância, e aumentos de 0,40° e 0,41° para as inclinações mesiodistal e vestibulolingual, respectivamente. As discrepâncias entre EX30® e SmartTrack® foram comparadas por regressão linear multinível. Conclusão: Os alinhadores EX30® alcançaram maior previsibilidade para a inclinação vestibulolingual em dentes anteriores. No entanto, para rotação e inclinação mesiodistal, SmartTrack® e EX30® apresentaram previsibilidade similar. A quantidade total de movimento planejado apresenta influência significativa nas taxas de previsibilidade, com diminuição na acurácia para cada grau adicional.

15.
Einstein (Säo Paulo) ; 22: eAE0780, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1557723

RESUMO

ABSTRACT Objective We aimed to share our experience in implementing a structured system for COVID-19 lung findings, elucidating key aspects of the lung ultrasound score to facilitate its standardized clinical use beyond the pandemic scenario. Methods Using a scoring system to classify the extent of lung involvement, we retrospectively analyzed the ultrasound reports performed in our institution according to COVID-RADS standardization. Results The study included 69 thoracic ultrasound exams, with 27 following the protocol. The majority of patients were female (52%), with ages ranging from 1 to 96 years and an average of 56 years. Classification according to COVID-RADS was as follows: 11.1% in category 0, 37% in category 1, 44.4% in category 2, and 7.4% in category 3. Ground-glass opacities on tomography correlated with higher COVID-RADS scores (categories 2 and 3) in 82% of cases. Ventilatory assessment revealed that 50% of cases in higher COVID-RADS categories (2 and 3) required second-line oxygen supplementation, while none of the cases in lower categories (0 and 1) utilized this support. Conclusion Lung ultrasound has been widely utilized as a diagnostic tool owing to its availability and simplicity of application. In the context of the pandemic emergency, a pressing need for a focused and easily applicable assessment arose. The structured reporting system, incorporating ultrasound findings for stratification, demonstrated ease of replicability. This system stands as a crucial tool for screening, predicting severity, and aiding in medical decisions, even in a non-pandemic context.

16.
Diagnostics (Basel) ; 13(23)2023 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-38066734

RESUMO

Gastroenterology is increasingly moving towards minimally invasive diagnostic modalities. The diagnostic exploration of the colon via capsule endoscopy, both in specific protocols for colon capsule endoscopy and during panendoscopic evaluations, is increasingly regarded as an appropriate first-line diagnostic approach. Adequate colonic preparation is essential for conclusive examinations as, contrary to a conventional colonoscopy, the capsule moves passively in the colon and does not have the capacity to clean debris. Several scales have been developed for the classification of bowel preparation for colon capsule endoscopy. Nevertheless, their applications are limited by suboptimal interobserver agreement. Our group developed a deep learning algorithm for the automatic classification of colonic bowel preparation, according to an easily applicable classification. Our neural network achieved high performance levels, with a sensitivity of 91%, a specificity of 97% and an overall accuracy of 95%. The algorithm achieved a good discriminating capacity, with areas under the curve ranging between 0.92 and 0.97. The development of these algorithms is essential for the widespread adoption of capsule endoscopy for the exploration of the colon, as well as for the adoption of minimally invasive panendoscopy.

17.
Biology (Basel) ; 12(11)2023 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-37998050

RESUMO

Biomass storage is an essential requirement in the supply chain of bio-refineries and power plants. This research aims to evaluate the influence of long-term outdoor storage (1 year) of baled rockrose (Cistus laurifolius L.) shrub biomass on biofuel's quality, pre-treatment processes and on combustion emissions in an industrial boiler. The raw material was obtained from different rockrose shrublands in north central Spain. A total of 233 tWM (tones of wet matter) of biomass were used to produce biofuels (30 mm of milled biomass and Ø 8 mm pellets) in the pre-treatment pilot plants at CEDER-CIEMAT. The combustion tests were conducted in an industrial moving grate boiler with a thermal power of 50 MWth, in a 17 MWe power plant. Outdoor storage improved some biofuel quality parameters, mainly the reduction in ash content, which allowed 30 mm of milled material to be classified as class I1 (ISO 17225-9:2022) and pellets as class I3 (ISO 17225-2-2021). No significant differences were observed in the total specific mass flow and energy consumption in the pre-treatment processes. The combustion tests had similar results, with the emissions being below the limits established in the directive (EU) 2015/2193. The results obtained indicated that the 1-year outdoor storage of rockrose-baled biomass, under Mediterranean conditions, was feasible for its subsequent use as biofuel.

19.
J Am Coll Radiol ; 2023 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-37922968

RESUMO

PURPOSE: The aim of this study was to evaluate an interuniversity competition online to learn radiology held in a 3-D virtual world, the Second Life metaverse, by analyzing the results of the game and students' perceptions. METHODS: Medical students voluntarily participated in teams of four, for 6 weeks, successively covering radiologic anatomy and radiologic semiology of the chest, abdomen, and musculoskeletal. Each week, participants had 4.5 days to study self-learning presentations and 2.5 days to complete an individual multiple-choice test and a team task, the results of which determined the game's ranking. Participants were asked to complete a cognitive-load test, a perception questionnaire, and a postexposure knowledge test. RESULTS: The competition was repeated for 2 years (editions), in 2020 and 2021. Seventy-five of 102 teams (73.5%) registered completed the game; 76% of them included third-year students. The average percentage of correct answers in the individual tests and team tasks was 74.2 ± 15.1 and 71.6 ± 14.7 respectively, without significant differences between both competitions. In general, the experience was valued positively (scores >8 on a 10-point scale). A lower perception score was found in 2021 among students from universities other than the organizing university, showing a positive correlation with the in-game score. CONCLUSIONS: An interuniversity competition in the Second Life metaverse for undergraduate learning radiology is feasible and reproducible. Participating medical students considered it interesting and useful and also identified this activity during the 2 years of the coronavirus disease 2019 pandemic as a playful learning and social interaction experience.

20.
Animals (Basel) ; 13(22)2023 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-38003158

RESUMO

Intrauterine growth restriction in piglets has been a problem in the pig industry due to genetic selection based on hyperprolificacy. This has led to an increase in the number of underweight piglets and a worsening of the survival rate. The goal of this study was to enhance the knowledge of differences between normal and IUGR piglets a few hours after birth in terms of haematological variables, biochemical parameters, and immunoglobulin levels. Two groups of 20 piglets each were assessed. The control group (N) was made up of piglets with weights greater than 1500 g, and the IUGR group consisted of piglets weighing 500-1000 g and with at least two IUGR features. Blood samples were collected 72 h after birth for analysis of the red and white blood cell parameters, reticulocyte indices, platelet indices, biochemical parameters, and immunoglobulin levels. Alterations in red blood cells and reticulocytes, a lower lymphocyte count, hyperinsulinemia, and high oxidative stress were observed in IUGR piglets (p < 0.05). In contrast, differences were not observed (p > 0.05) in the serum immunoglobulin level. It can be concluded that the haematological and biochemical differences in IUGR piglets with respect to normal-weight piglets are present at birth indicating possible alterations in immunity, metabolism, and redox status; therefore, IUGR piglets could be more vulnerable to illness and future disorders, such as metabolic syndrome.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...