Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Monit Comput ; 20(3): 145-50, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16794892

RESUMO

OBJECTIVE: N(2)O is a commonly used anesthetic that has amnestic and analgesic properties. Recently, devices that estimate depth of consciousness have been introduced in an attempt to better titrate anesthesia, however the effect of N(2)O on these monitors is unclear. METHODS: General anesthesia was induced and titrated to maintain normal blood pressure and pulse in healthy adults. Data were collected in three 10 minute intervals (Sevo, Sevo + N(2)O, Sevo). In Phase A, sevoflurane concentration was held constant during the N(2)O trial in 60 subjects monitored with either BIS, PSI, or Entropy. In Phase B, sevoflurane concentration was reduced as N(2)O was added, maintaining a constant overall "MAC" in 20 subjects monitored concurrently with BIS and Entropy. Sample size for both phases was designed to detect a 10 unit change in measure of processed EEG with alpha = .05 and statistical power = .80. RESULTS: In Phase A, supplementing sevoflurane with > 65% N(2)O increased MAC from 1.3 +/- 0.05 to 2.2 +/- 0.10, but did not significantly alter BIS nor PSI (p-value for differential MAC is < 0.05). Entropy, however, dropped significantly, with a change in state entropy (SE) from 31.1 +/- 7.3 to 18.9 +/- 3.7 and a corresponding rise when N(2)O was discontinued. In Phase B, supplementing sevoflurane with > 65% N(2)O with a concomitant reduction in sevoflurane resulted in an increase in both BIS (from 34 +/- 5 to 53.9 +/- 11.5) and SE (from 32 +/- 8.2 to 55.4 +/- 21.3). CONCLUSION: Supplementing sevoflurane with > 65% N(2)O did not result in a significant change in either BIS or PSI when sevoflurane concentration was kept constant. Entropy, however, significantly decreased as anesthetic depth increased. When sevoflurane concentration was reduced during N(2)O administration, both BIS and Entropy rose despite maintenance of anesthetic depth, indicating a variable concentration effect between volatiles and N(2)O.


Assuntos
Algoritmos , Encéfalo/efeitos dos fármacos , Estado de Consciência/efeitos dos fármacos , Eletroencefalografia/efeitos dos fármacos , Éteres Metílicos/administração & dosagem , Óxido Nitroso/administração & dosagem , Adulto , Anestésicos Inalatórios/administração & dosagem , Encéfalo/fisiologia , Estado de Consciência/fisiologia , Relação Dose-Resposta a Droga , Combinação de Medicamentos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Sevoflurano
2.
Anesth Analg ; 101(2): 474-480, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16037164

RESUMO

UNLABELLED: Inadequate analgesia in hospitalized patients prompted the Joint Commission on Accreditation of Healthcare Organizations in 2001 to introduce standards that require pain assessment and treatment. In response, many institutions implemented treatment guided by patient reports of pain intensity indexed with a numerical scale. Patient safety associated with treatment of pain guided by a numerical pain treatment algorithm (NPTA) has not been examined. We reviewed patient satisfaction with pain control and opioid-related adverse drug reactions before and after implementation of our NPTA. Patient satisfaction with pain management, measured on a 1-5 scale, significantly improved from 4.13 to 4.38 (P < 0.001) after implementation of an NPTA. The incidence of opioid over sedation adverse drug reactions per 100,000 inpatient hospital days increased from 11.0 pre-NPTA to 24.5 post-NPTA (P < 0.001). Of these patients, 94% had a documented decrease in their level of consciousness preceding the event. Although there was an improvement in patient satisfaction, we experienced a more than two-fold increase in the incidence of opioid over sedation adverse drug reactions in our hospital after the implementation of NPTA. Most adverse drug reactions were preceded by a documented decrease in the patient's level of consciousness, which emphasizes the importance of clinical assessment in managing pain. IMPLICATIONS: Although patient satisfaction with pain management has significantly improved since the adoption of pain management standards, adverse drug reactions have more than doubled. For the treatment of pain to be safe and effective, we must consider more than just a one-dimensional numerical assessment of pain.


Assuntos
Hospitais/normas , Manejo da Dor , Medição da Dor/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Analgésicos Opioides/efeitos adversos , Analgésicos Opioides/uso terapêutico , Overdose de Drogas , Feminino , Guias como Assunto , Humanos , Hipnóticos e Sedativos/efeitos adversos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Segurança
3.
J Clin Anesth ; 17(1): 44-50, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15721729

RESUMO

STUDY OBJECTIVE: To discover if reducing respiratory system impedance would increase tidal volume and improve ventilation during inhalation anesthesia. DESIGN: Prospective, randomized cross-over study. SUBJECTS: Nine ASA physical status I and II adult female oncology patients undergoing breast operations with or without lymph node dissection and general anesthesia while breathing spontaneously. INTERVENTIONS AND MEASUREMENTS: Patients underwent alternating trials of constant positive airway pressure, with or without pressure support. Constant positive airway pressure and pressure support were titrated to maximize respiratory system compliance and equal inspiratory pressure gradient across tracheal tube, respectively. Variables reflecting cardiovascular function, pulmonary mechanics and lung gas exchange, and respired gases and isoflurane concentrations were measured. MAIN RESULTS: End-tidal concentration of isoflurane (1.3 +/- 0.2%), Fio(2) (0.43 +/- 0.09 ), and CO(2) elimination (209 +/- 42 mL min(-1)) was unchanged throughout study in patients aged 63 +/- 12 years, weighing 72 +/- 12 kg. Constant positive airway pressure (12 +/- 2 cm H(2)O) increased respiratory system compliance from 52 +/- 8 to 80 +/- 9 mL cm H(2)O(-1) (P < .001), tidal volume from 156 +/- 32 to 325 +/- 52 mL (P < .001), and minute ventilation from 4.37 +/- 0.86 to 6.18 +/- 0.92 L min(-1) (P < .001). Respiratory rate decreased from 29 +/- 7 to 19 +/- 2 min(-1) (P < .001), Paco(2) decreased from 54 +/- 8 to 44 +/- 6 mm Hg (P < .001), and Pao(2) increased from 137 +/- 37 to 160 +/- 64 mm Hg (P < .001). Pressure support (3.1 +/- 0.3 cm H(2)O) did not alter ventilation or gas exchange. CONCLUSION: We conclude that constant positive airway pressure titrated to optimal respiratory system compliance will increase efficiency of inspiratory muscles and improve ventilation. Constant positive airway pressure facilitates a pattern of breathing that minimizes some of the adverse pulmonary effects of inhalation anesthesia.


Assuntos
Anestesia por Inalação/efeitos adversos , Hipoventilação/induzido quimicamente , Hipoventilação/terapia , Respiração com Pressão Positiva , Idoso , Resistência das Vias Respiratórias/fisiologia , Neoplasias da Mama/cirurgia , Estudos Cross-Over , Eletrocardiografia/efeitos dos fármacos , Feminino , Humanos , Pessoa de Meia-Idade , Monitorização Intraoperatória , Oxigênio/sangue , Músculos Respiratórios/fisiologia , Volume de Ventilação Pulmonar/fisiologia
4.
Chest ; 126(5): 1552-8, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15539726

RESUMO

STUDY OBJECTIVE: This two-part study was designed to determine the effect of supplemental oxygen on the detection of hypoventilation, evidenced by a decline in oxygen saturation (Spo(2)) with pulse oximetry. DESIGN: Phase 1 was a prospective, patient-controlled, clinical trial. Phase 2 was a prospective, randomized, clinical trial. SETTING: Phase 1 took place in the operating room. Phase 2 took place in the postanesthesia care unit (PACU). PATIENTS: In phase 1, 45 patients underwent abdominal, gynecologic, urologic, and lower-extremity vascular operations. In phase 2, 288 patients were recovering from anesthesia. INTERVENTIONS: In phase 1, modeling of deliberate hypoventilation entailed decreasing by 50% the minute ventilation of patients receiving general anesthesia. Patients breathing a fraction of inspired oxygen (Fio(2)) of 0.21 (n = 25) underwent hypoventilation for up to 5 min. Patients with an Fio(2) of 0.25 (n = 10) or 0.30 (n = 10) underwent hypoventilation for 10 min. In phase 2, spontaneously breathing patients were randomized to breathe room air (n = 155) or to receive supplemental oxygen (n = 133) on arrival in the PACU. MEASUREMENTS AND RESULTS: In phase 1, end-tidal carbon dioxide and Spo(2) were measured during deliberate hypoventilation. A decrease in Spo(2) occurred only in patients who breathed room air. No decline occurred in patients with Fio(2) levels of 0.25 and 0.30. In phase 2, Spo(2) was recorded every min for up to 40 min in the PACU. Arterial desaturation (Spo(2) < 90%) was fourfold higher in patients who breathed room air than in patients who breathed supplemental oxygen (9.0% vs 2.3%, p = 0.02). CONCLUSION: Hypoventilation can be detected reliably by pulse oximetry only when patients breathe room air. In patients with spontaneous ventilation, supplemental oxygen often masked the ability to detect abnormalities in respiratory function in the PACU. Without the need for capnography and arterial blood gas analysis, pulse oximetry is a useful tool to assess ventilatory abnormalities, but only in the absence of supplemental inspired oxygen.


Assuntos
Hipoventilação/sangue , Hipoventilação/diagnóstico , Oximetria , Idoso , Feminino , Humanos , Hipoventilação/terapia , Masculino , Pessoa de Meia-Idade , Oxigenoterapia , Estudos Prospectivos
5.
Anesth Analg ; 99(2): 379-82, table of contents, 2004 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15271710

RESUMO

Apnea and airway obstruction are common during monitored anesthesia care (MAC). Because their early detection is essential, we sought to measure the efficacy of capnography as an indicator of apnea during MAC at a variety of oxygen flow rates compared with thoracic impedance. Anesthesia care providers using standard American Society of Anesthesiologists monitors were blinded to capnography and thoracic impedance monitoring. Ten (26%) of the 39 patients studied developed 20 s of apnea; none was detected by the anesthesia provider, but all were detected by capnography and impedance monitoring. There was no difference in detection rates between the two methods. Higher oxygen flow rates decreased the amplitude of the capnograph but did not interfere with apnea detection. This pilot study revealed that apnea of at least 20 s in duration may occur in every fourth patient undergoing MAC. Although these episodes were undetected by the anesthesia provider, they were reliably detected by both capnography and respiratory plethysmography. Monitoring of nasal end-tidal CO(2) is an important way to improve safety in patients undergoing MAC.


Assuntos
Anestesia , Apneia/diagnóstico , Capnografia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Dióxido de Carbono/sangue , Cardiografia de Impedância , Sedação Consciente , Feminino , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória , Oxigênio/administração & dosagem , Oxigênio/sangue , Projetos Piloto , Pletismografia , Mecânica Respiratória/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...