Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Steroid Biochem Mol Biol ; 84(5): 577-88, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12767283

RESUMO

We present a method for the determination of the isoflavan equol in plasma and urine. This estrogenic isoflavan, which is formed by the action of the intestinal microflora, may have higher biological activity than its precursor daidzein. High urinary excretion of equol has been suggested to be associated with a reduction in breast cancer risk. The method is based on time-resolved fluoroimmunoassay, using a europium chelate as a label. After synthesis of 4'-O-carboxymethylequol the compound is coupled to bovine serum albumin (BSA), then used as antigen to immunize rabbits. The tracer with the europium chelate is synthesized using the same 4'-O-derivative of equol. After enzymatic hydrolysis (urine) or enzymatic hydrolysis and ether extraction (plasma) the immunoassay is carried out. The antiserum cross-reacted to variable extent with some isoflavonoids. For the plasma method the cross-reactivity does not seem to influence the results, which were highly specific. The overestimation of the values using the urine method (164%) compared to the results obtained by a gas chromatography-mass spectrometry (GC-MS) method is probably due to some influence of the matrix on the signal, and interference of structurally related compounds. It is suggested that plasma assays are used but if urine samples are measured a formula has to be used to correct the values making them comparable to the GC-MS results. The correlation coefficients between the time-resolved fluoroimmunoassay (TR-FIA) methods and GC-MS methods were high; r-values for the plasma and urine method, were 0.98 and 0.91, respectively. The intra-assay coefficient of variation (CV%) for the TR-FIA plasma and urine results at three different concentrations vary between 5.5-6.5 and 3.4-6.9, respectively. The inter-assay CV% varies between 5.4-9.7 and 7.4-7.7, respectively. The working ranges of the plasma and urine assay are 1.27-512 and 1.9-512nmol/l, respectively.


Assuntos
Cromanos/sangue , Cromanos/urina , Fluorimunoensaio/métodos , Animais , Formação de Anticorpos , Bovinos , Cromanos/química , Cromanos/imunologia , Reações Cruzadas , Equol , Európio/química , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Soros Imunes , Isoflavonas/sangue , Isoflavonas/química , Isoflavonas/imunologia , Isoflavonas/urina , Coelhos , Sensibilidade e Especificidade , Soroalbumina Bovina
2.
J Steroid Biochem Mol Biol ; 81(4-5): 353-61, 2002 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12361725

RESUMO

We present a method for the determination of the phytoestrogen metabolite O-desmethylangolensin (O-DMA) in plasma (serum) and in urine. O-DMA is a metabolite of daidzein, which occurs in soybeans. It has been suggested that isoflavones may afford protection against breast and prostate cancer and therefore, also the metabolites are of interest. The method is based on time-resolved fluoroimmunoassay (TR-FIA) using a europium chelate as a label. After the synthesis of 4"-O-carboxymethyl-O-DMA, this compound is coupled to bovine serum albumin, and then used as antigen in immunization of rabbits. The tracers with the europium chelate are synthesized using the same 4"-O-derivative of the alpha-methyldeoxybenzoin. After enzymatic hydrolysis and ether extraction the immunoassay is carried out by time resolved fluoroimmunoassay (TR-FIA). Cross-reactivity was tested with angolensin, dihydrogenistein, dihydrodaidzein, equol, 6'-OH-angolensin, trans-4-OH-equol, 6'-OH-O-DMA, cis-4-OH-equol and 5-OH-equol. The antiserum cross-reacted only with angolensin. This cross-reactivity seems not to influence the results, which were highly specific. Plasma samples are hydrolyzed and extracted. Urine samples are analyzed directly after hydrolysis without extraction. The correlation coefficient between the plasma TR-FIA results and the GC-MS results was high; r value was 0.985. The correlation coefficient between the urine TR-FIA results and the GC-MS results was high over the entire range of concentrations (0-1500 nmol/l); r value was 0.976, but lower in the low concentration range (0-100 nmol/l), i.e. value was 0.631. The intra-assay coefficients of variation (CVs) for plasma O-DMA concentrations and for urine O-DMA concentrations at three different concentrations varied 2.8-7.7 and 3.0-6.0%, respectively and the inter-assay CVs varied 3.8-8.9 and 4.4-6.6%, respectively. The working range of the plasma and urine O-DMA assays was 0.5-512 nmol/l.


Assuntos
Fluorimunoensaio/métodos , Isoflavonas/sangue , Isoflavonas/urina , Animais , Formação de Anticorpos , Reações Cruzadas , Estudos de Avaliação como Assunto , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Soros Imunes , Isoflavonas/imunologia , Coelhos , Sensibilidade e Especificidade , Soroalbumina Bovina , Glycine max
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...