Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Clin Pathol ; 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38741421

RESUMO

OBJECTIVES: To evaluate the utility of the dilute prothrombin time (DPT) in diagnosing antiphospholipid syndrome (APS), alone and when paired with the dilute Russell viper venom time (DRVVT). METHODS: Dilute prothrombin time and DRVVT testing was performed on plasma samples spiked with apixaban or rivaroxaban, or depleted of vitamin K-dependent clotting factors. A retrospective analysis of all functional APS testing results over a 44-month period at the University of Chicago Medical Center was performed. RESULTS: In spiking studies, the screening clotting time in the DPT (DPTS) is more sensitive to deficiency of vitamin K-dependent factors than is the screening clotting time in the DRVVT (DRVVTS). The converse is true for factor Xa direct oral anticoagulant (DOAC)-spiked plasma. In a 44-month retrospective analysis, only 2.6% of clinical APS panels showed isolated positivity in the DPT-based system. Comparing the DPT-based system with the DRVVT-based system showed utility in identifying false-positive DRVVT results due to anticoagulation. A DRVVTS/DPTS ratio of 0.785 or lower predicted an international normalized ratio of 1.5 or higher (sensitivity, 86.3%; specificity, 60.4%; likelihood ratio, 2.18). Conversely, a DRVVTS/DPTS ratio of 1.165 or higher was the optimal cutoff for predicting the identification of factor Xa DOAC (sensitivity, 61.8%; specificity, 77.8%; likelihood ratio, 2.78). Within the data set that had full DRVVT and DPT results, parameters were identified that could further improve identification of samples with anticoagulation interference. CONCLUSIONS: Dilute prothrombin time lupus anticoagulant assay is rarely the sole laboratory functional evidence for APS, but when combined with the DRVVT, the DPT can serve as an effective screen for common anticoagulant interference.

2.
Am J Clin Pathol ; 160(5): 455-465, 2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37415401

RESUMO

OBJECTIVES: The sensitivity and specificity of clot lysis at 30 minutes after maximum clot strength (LY30), as measured by thromboelastography (TEG), for clinically significant hyperfibrinolysis have not been compared across the 2 US Food and Drug Administration-approved instruments (the TEG 5000 and TEG 6s [Haemonetics]). METHODS: We performed a retrospective, single-center analysis of these 2 instruments using the kaolin (CK) reagent. RESULTS: Local verification studies showed that the TEG 5000 and TEG 6s CK LY30 upper limits of normal (ULNs) were distinct (5.0% and 3.2%, respectively). Retrospective analysis of patient data showed that abnormal LY30 was 6 times more prevalent with the TEG 6s than with the TEG 5000 instrument. LY30 was a significant predictor of mortality with both instruments (TEG 6s: receiver operating characteristic [ROC] area under the curve [AUC] = 0.836, P ≤ .0001; TEG 5000: ROC AUC = 0.779, P = .028). The optimal LY30 cut point was determined based on these mortality data for each instrument. The TEG 6s showed superior mortality prediction than the TEG 5000 at lower LY30 levels (≥10%), with likelihood ratios of 8.22 and 2.62 for the TEG 6s and TEG 5000, respectively. Patients with a TEG 6s CK LY30 of 10% or higher were significantly more likely to die, receive cryoprecipitate, receive transfusions, or receive massive transfusion than patients with a TEG 6s LY30 of 3.3% to 9.9% (all P < .01). Patients with a TEG 5000 LY30 of 17.1% or higher were significantly more likely to die or use cryoprecipitate (P < .05); transfusion and massive transfusion protocol were not significantly different. Whole blood spiking studies showed that 70 ng/mL tissue plasminogen activator (tPA) achieved an average LY30 of approximately 10% for both instruments. CONCLUSIONS: CK LY30 above the ULN is a sensitive but not specific cutoff for hyperfibrinolysis. At least moderately elevated CK LY30 carries more clinical portent on the TEG 6s instrument than on the TEG 5000. These TEG instruments are not sensitive to low concentrations of tPA.


Assuntos
Transtornos da Coagulação Sanguínea , Tromboelastografia , Humanos , Ativador de Plasminogênio Tecidual , Estudos Retrospectivos , Sensibilidade e Especificidade
3.
Am J Clin Pathol ; 156(5): 818-828, 2021 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-33978149

RESUMO

OBJECTIVES: To compare the performance of the TEG 5000 and TEG 6S Global Hemostasis cartridge. METHODS: We reviewed validation data of the TEG 5000 and TEG 6S Global Hemostasis cartridge. The specimens were analyzed in parallel according to the manufacturer's operating instructions. RESULTS: Fifty-four healthy donors and 13 donors with known hemostatic abnormalities were included. The correlations between instrument types were only moderate-the Spearman rank correlations were 0.55, 0.62, 0.64, and 0.72, respectively, for CK R, K, angle, and maximum amplitude (MA) parameters. Using the manufacturer's device-specific reference ranges to classify results as normal/abnormal, there was weak agreement in the qualitative interpretation of all parameters (Cohen's κ for agreement for CK R, K, angle, and MA was 0.418, 0.154, -0.083, and 0.127, respectively). This could lead to discordant transfusion decisions. CONCLUSIONS: These findings indicate that the TEG 5000 and TEG 6S may not be used interchangeably.


Assuntos
Tromboelastografia/instrumentação , Humanos , Valores de Referência , Estudos Retrospectivos , Tromboelastografia/normas
4.
Am J Clin Pathol ; 155(6): 863-872, 2021 05 18.
Artigo em Inglês | MEDLINE | ID: mdl-33386737

RESUMO

OBJECTIVES: This study was undertaken to explore the feasibility of assessing platelet dense granule release in response to platelet stimuli, using less than 1 mL of whole blood (WB). METHODS: Optimization of the luciferin-luciferase (LL) assay for ATP release, together with additional modifications, was applied to 1:10 diluted WB. RESULTS: LL assay optimization using nonstirred 1:10 diluted WB resulted in dense granule ATP release in response to thrombin receptor-activating peptide (TRAP) of similar magnitude to that observed using stirred platelet-rich plasma. Stirring of the 1:10 diluted WB restored collagen-induced dense granule secretion. Addition of lyophilized, formalin-fixed platelets, together with stirring, restored dense granule secretion responsiveness to ADP. TRAP, ADP, and collagen all stimulated ATP release in 1:10 diluted WB under the optimized conditions of this study at levels close to those observed using platelet-rich plasma. Blood sample reconstitution experiments offer hope that this assay may prove robust down to WB platelet counts as low as 50 × 103/µL. CONCLUSIONS: Platelet dense granule release in response to a number of classic stimuli, including ADP, was accomplished from less than 1 mL WB with minimal specimen processing, using widely available reagents and instrumentation.


Assuntos
Trifosfato de Adenosina/sangue , Plaquetas/efeitos dos fármacos , Formaldeído/farmacologia , Agregação Plaquetária/efeitos dos fármacos , Trombina/farmacologia , Plaquetas/fisiologia , Humanos , Contagem de Plaquetas
5.
Am J Clin Pathol ; 152(6): 718-724, 2019 11 04.
Artigo em Inglês | MEDLINE | ID: mdl-31365739

RESUMO

OBJECTIVES: Analysis of platelet functional responses to stimuli is presently quite limited with respect to measurement of dense granule secretion. We sought to develop a nonradioactive assay of stimulated serotonin release using liquid chromatography tandem mass spectrometry (LC-MS/MS). METHODS: Citrated whole blood (200 µL) was incubated with deuterated serotonin (d45-HT). Following uptake by platelets, blood was diluted 10-fold and aliquots were incubated with platelet stimuli. Following stimulation, blood was further diluted, centrifuged, and supernatant was assayed for released d45-HT by micro-LC-MS/MS. RESULTS: This study demonstrated a broad linear range of 50 to 2,000 pg/mL d45-HT, with a total precision of less than 15.0% coefficient of variation at all quality control levels and a limit of quantitation of 50 pg/mL. CONCLUSIONS: Quantification of d45-HT by micro-LC-MS/MS assay offers a highly sensitive, nonradioactive methodology for quantitating platelet serotonin uptake and dense granule secretion, requiring only small volumes of patient blood.


Assuntos
Cromatografia Líquida/métodos , Testes de Função Plaquetária/métodos , Serotonina/análise , Espectrometria de Massas em Tandem/métodos , Humanos , Serotonina/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...