1.
Phys Rev Lett ; 130(14): 145103, 2023 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-37084458

RESUMO

Inverse bremsstrahlung absorption was measured based on transmission through a finite-length plasma that was thoroughly characterized using spatially resolved Thomson scattering. Expected absorption was then calculated using the diagnosed plasma conditions while varying the absorption model components. To match data, it is necessary to account for (i) the Langdon effect; (ii) laser-frequency (rather than plasma-frequency) dependence in the Coulomb logarithm, as is typical of bremsstrahlung theories but not transport theories; and (iii) a correction due to ion screening. Radiation-hydrodynamic simulations of inertial confinement fusion implosions have to date used a Coulomb logarithm from the transport literature and no screening correction. We anticipate that updating the model for collisional absorption will substantially revise our understanding of laser-target coupling for such implosions.

2.
Rev Sci Instrum ; 93(12): 123510, 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36586936

RESUMO

Measurements of laser absorption in high-temperature, underdense plasmas produced at the Omega Laser Facility are made using two near-field imaging detectors that diagnose the spatial profile and energy of the port P9 beam before and after it transmits through the plasma. The incident beam is sampled using a partial reflection from a full-aperture, (30 cm-diam) uncoated wedge pickoff located before the target chamber vacuum window and final focus lens assembly. A concave mirror reduces the reflected beam size, allowing it to be recorded directly using a charged-coupled device (CCD) camera. The P9 transmitted beam diagnostic (P9TBD) characterizes the transmitted light by terminating the expanded beam on a semi-transparent diffuser and imaging the illuminated surface using a lens and CCD camera. The P9TBD samples a numerical aperture twice as large as the input beam, allowing the energy of transmitted beams with moderate levels of beam spray to be measured accurately. Calibration shots with no plasma provide a path to infer absorption without absolute photometric calibration of either detector. The cross-calibration between the two detectors was measured to remain stable at ±200 ppm, enabling measurements of total beam absorption below 1% with ±0.07% error.

3.
Phys Rev Lett ; 129(11): 115002, 2022 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-36154407

RESUMO

Measurements were made of the return current instability growth rate, demonstrating its concurrence with nonlocal transport. Thomson scattering was used to measure a maximum growth rate of 5.1×10^{9} Hz, which was 3 times less than classical Spitzer-Härm theory predicts. The measured plasma conditions indicate the heat flux was nonlocal, and Vlasov-Fokker-Planck simulations that account for nonlocality reproduce the measured growth rates. Furthermore, the threshold for the return current instability was measured (δ_{T}=0.017±0.002) to be in good agreement with previous theoretical models.

4.
Phys Rev Lett ; 127(1): 015001, 2021 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-34270287

RESUMO

Electron velocity distribution functions driven by inverse bremsstrahlung heating are measured to be non-Maxwellian using a novel angularly resolved Thomson-scattering instrument and the corresponding reduction of electrons at slow velocities results in a ∼40% measured reduction in inverse bremsstrahlung absorption. The distribution functions are measured to be super-Gaussian in the bulk (v/v_{th}<3) and Maxwellian in the tail (v/v_{th}>3) when the laser heating rate dominates over the electron-electron thermalization rate. Simulations with the particle code quartz show the shape of the tail is dictated by the uniformity of the laser heating.

5.
Phys Rev Lett ; 126(7): 075002, 2021 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-33666470

RESUMO

We measure cross-beam energy transfer (CBET) saturation by ion heating in a gas-jet plasma characterized using Thomson scattering. A wavelength-tunable ultraviolet (UV) probe laser beam interacts with four intense UV pump beams to drive large-amplitude ion-acoustic waves. For the highest-intensity interactions, the power transfer to the probe laser drops, demonstrating ion-acoustic wave saturation. Over this time, the ion temperature is measured to increase by a factor of 7 during the 500-ps interaction. Particle-in-cell simulations show ion trapping and a subsequent ion heating consistent with measurements. Linear kinetic CBET models are found to agree well with the observed energy transfer when the measured plasma conditions are used.

6.
Phys Rev Lett ; 124(2): 025001, 2020 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-32004052

RESUMO

The picosecond evolution of non-Maxwellian electron distribution functions was measured in a laser-produced plasma using collective electron plasma wave Thomson scattering. During the laser heating, the distribution was measured to be approximately super-Gaussian due to inverse bremsstrahlung heating. After the heating laser turned off, collisional ionization caused further modification to the distribution function while increasing electron density and decreasing temperature. Electron distribution functions were determined using Vlasov-Fokker-Planck simulations including atomic kinetics.

7.
Rev Sci Instrum ; 90(3): 033503, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30927775

RESUMO

A versatile set of methods for analyzing x-ray energy spectra and photon flux has been developed for laser plasma accelerator experiments driven by picosecond lasers. Forward fit provides extrapolated broad energy spectrum measurements, while Ross pair and differential average transmission analysis provide directly measured data points using a particular diagnostic. Combining these methods allows the measurement of x-ray energy spectra with improved confidence. We apply the methods to three diagnostics (filter wheel, stacked image plate spectrometer, and step wedge), each sensitive to a different region of x-ray energies (<40 keV, 35-100 keV, and 60-1000 keV, respectively), to characterize the analysis methods using laser-driven bremsstrahlung x-rays. We then apply the methods to measure three x-ray mechanisms, betatron, inverse Compton scattering, and bremsstrahlung, driven by a laser plasma accelerator. The analysis results in the measurement of x-ray energy spectra ranging from 10 keV to 1 MeV with peak flux greater than 1010 photons/keV/Sr. The combined analysis methods provide a robust tool to accurately measure broadband x-ray sources (keV to MeV) driven by laser plasma acceleration with picosecond, kilojoule-class lasers.

8.
Phys Rev Lett ; 120(22): 225001, 2018 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-29906187

RESUMO

Flying focus is a technique that uses a chirped laser beam focused by a highly chromatic lens to produce an extended focal region within which the peak laser intensity can propagate at any velocity. When that intensity is high enough to ionize a background gas, an ionization wave will track the intensity isosurface corresponding to the ionization threshold. We report on the demonstration of such ionization waves of arbitrary velocity. Subluminal and superluminal ionization fronts were produced that propagated both forward and backward relative to the ionizing laser. All backward and all superluminal cases mitigated the issue of ionization-induced refraction that typically inhibits the formation of long, contiguous plasma channels.

9.
Phys Rev Lett ; 84(7): 1389-92, 2000 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-11017525

RESUMO

We report results from Experiment 871, performed at the BNL AGS, of a measurement of the branching ratio K(0)(L)-->&mgr;(+)&mgr;(-) with respect to the CP-violating mode K(0)(L)-->pi(+)pi(-). This experiment detected over 6200 candidate &mgr;(+)&mgr;(-) events, a factor of 6 more than that seen in all previous measurements combined. The resulting branching ratio gamma(K(0)(L)-->&mgr;(+)&mgr;(-))/gamma(K(0)(L)-->pi(+)pi(-)) = (3. 474+/-0.057)x10(-6) leads to a branching fraction B(K(0)(L)-->&mgr;(+)&mgr;(-)) = (7.18+/-0.17)x10(-9), which is consistent with the current world average, and reduces the uncertainty in this decay mode by a factor of 3.