Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Vet Med Int ; 2024: 2313447, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38818029

RESUMO

The application of the erythrocyte sedimentation rate (ESR) in feline medicine is currently unavailable, while in canine medicine it has been rediscovered due to the introduction of an automated ESR device. Our aims were to (1) define the reference interval (RI) of the ESR in healthy cats, (2) evaluate the ESR values between healthy and ill cats, (3) evaluate relationships between the ESR and some inflammatory markers, and (4) assess ESR changes in different durations of illness (acute, chronic, or acute-on-chronic). A prospective multicentric cohort study on 200 client-owned cats: 57 healthy cats and 143 ill cats for the other aims. Healthy cats were blood donors, or young cats underwent desexing procedures. Ill cats with full clinical medical records, hematobiochemical profiles, and diagnostic procedures to reach a final diagnosis were included. The ESR was performed with MINI-PET using the same K3-EDTA tubes used for CBC, with no additional sample required. The total leukocyte count (WBC), neutrophil-to-lymphocyte ratio (NLR), fibrinogen, serum amyloid A, and albumin/globulin ratio (A/G) were concurrently measured. Based on the clinical presentation and the final diagnosis, cats were classified as having the following: acute, chronic, and acute-on-chronic conditions. The RI of the ESR ranged between 1 and 23 mm/h. Ill cats showed a significantly higher ESR (median 29 mm/h; range 12-46 mm/h) than healthy cats (median 10 mm/h; range 1-12 mm/h; p < 0.0001). The ESR was positively correlated only with fibrinogen (p < 0.001; r = 0.43). Cats with acute-on-chronic diseases had the highest ESR (median 47 mm/h; range 35-56 mm/h) compared with acute (median 16 mm/h; range 14-42 mm/h; p=0.003) and chronic cats (median 14 mm/h; range 10-31 mm/h; p < 0.0001). Although further studies are needed, the ESR could be a useful ancillary inflammatory marker in cats, specifically in cats with acute diseases, with or without an underlying chronic condition.

2.
Vet Med Int ; 2020: 3146845, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32832062

RESUMO

The erythrocyte sedimentation rate (ESR) in canine medicine has been replaced by the evaluation of a few sensitive markers of the acute-phase proteins. The aim of the study was to evaluate the ESR using a point-of-care (MINIPET, DIESSE Diagnostica Senese S.p.A.) device (ESR-MP) and to compare the results with the gold standard Westergren method (ESR-W) in dogs. One hundred and nineteen K3-EDTA blood samples for complete blood count were randomly selected and assayed for ESR. The reference interval (RI) was established using the percentile method. The coefficient of variation (CV) in intra-assay and interassay precision of ESR-MP was calculated. The analytical sensitivity (Se), specificity (Sp), positive predictive values (PPVs), and negative predictive values (NPVs) were calculated. Agreement between ESR-MP and ESR-W was assessed with Pearson correlation coefficient (r), Cohen concordance test (K), Passing-Bablok regression, and Bland-Altman plots. Ten canine samples (8.4%) were ruled out because of flag-error by the MINIPET instrument (4.2%) or because they showed the diphasic pattern in ESR-W (4.2%). The canine RI of ESR-MP was 0-10 mm/h. Precision was excellent in intra-assay (CV = 0.02) and interassay (CV = 0.32). The analytical characteristics of ESR-MP in nonanemic samples were as follows: Se = 0.82, Sp = 0.95, PPV = 0.82, and NPV = 0.95. The accuracy of ESR-MP was better than ESR-W in nonanemic samples (r = 0.87; K = 0.77) and lower in anemic subjects (Hct <37%) (r = 0.76; K = 0.69). The Passing-Bablok regression showed the presence of systematic error and the absence of proportional error only in nonanemic blood samples. The Bland-Altman plots gave negative average values due to the difference in RIs and an agreement in both ESRs. The ESR-MP results can be obtained with the same K3-EDTA tubes used for the blood count, in shortcut time, and at reduced costs using the MINIPET device. These investigations highlight that ESR-MP could be useful in canine clinical settings.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...