Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
J Radiol Prot ; 39(4): R37-R50, 2019 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-31307030

RESUMO

This paper provides a summary of the Education and Training (E&T) activities that have been developed and organised by the European Radiation Dosimetry Group (EURADOS) in recent years and in the case of Training Courses over the last decade. These E&T actions include short duration Training Courses on well-established topics organised within the activity of EURADOS Working Groups (WGs), or one-day events integrated in the EURADOS Annual Meeting (workshops, winter schools, the intercomparison participants' sessions and the learning network, among others). Moreover, EURADOS has recently established a Young Scientist Grant and a Young Scientist Award. The Grant supports young scientists by encouraging them to perform research projects at other laboratories of the EURADOS network. The Award is given in recognition of excellent work developed within the WGs' work programme. Additionally, EURADOS supports the dissemination of knowledge in radiation dosimetry by promoting and endorsing conferences such as the individual monitoring (IM) series, the neutron and ion dosimetry symposia (NEUDOS) and contributions to E&T sessions at specific events.

2.
Phys Med Biol ; 63(8): 085017, 2018 04 19.
Artigo em Inglês | MEDLINE | ID: mdl-29509148

RESUMO

Systematic 3D mapping of out-of-field doses induced by a therapeutic proton pencil scanning beam in a 300 × 300 × 600 mm3 water phantom was performed using a set of thermoluminescence detectors (TLDs): MTS-7 (7LiF:Mg,Ti), MTS-6 (6LiF:Mg,Ti), MTS-N (natLiF:Mg,Ti) and TLD-700 (7LiF:Mg,Ti), radiophotoluminescent (RPL) detectors GD-352M and GD-302M, and polyallyldiglycol carbonate (PADC)-based (C12H18O7) track-etched detectors. Neutron and gamma-ray doses, as well as linear energy transfer distributions, were experimentally determined at 200 points within the phantom. In parallel, the Geant4 Monte Carlo code was applied to calculate neutron and gamma radiation spectra at the position of each detector. For the cubic proton target volume of 100 × 100 × 100 mm3 (spread out Bragg peak with a modulation of 100 mm) the scattered photon doses along the main axis of the phantom perpendicular to the primary beam were approximately 0.5 mGy Gy-1 at a distance of 100 mm and 0.02 mGy Gy-1 at 300 mm from the center of the target. For the neutrons, the corresponding values of dose equivalent were found to be ~0.7 and ~0.06 mSv Gy-1, respectively. The measured neutron doses were comparable with the out-of-field neutron doses from a similar experiment with 20 MV x-rays, whereas photon doses for the scanning proton beam were up to three orders of magnitude lower.


Assuntos
Imageamento Tridimensional/métodos , Imagens de Fantasmas , Terapia com Prótons/métodos , Radiometria/métodos , Dosimetria Termoluminescente/métodos , Raios gama , Humanos , Método de Monte Carlo , Nêutrons , Fótons , Prótons , Radioatividade , Cintilografia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Dosimetria Termoluminescente/instrumentação , Água
3.
Radiat Prot Dosimetry ; 180(1-4): 256-260, 2018 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-29165619

RESUMO

Proton beam therapy has advantages in comparison to conventional photon radiotherapy due to the physical properties of proton beams (e.g. sharp distal fall off, adjustable range and modulation). In proton therapy, there is the possibility of sparing healthy tissue close to the target volume. This is especially important when tumours are located next to critical organs and while treating cancer in paediatric patients. On the other hand, the interactions of protons with matter result in the production of secondary radiation, mostly neutrons and gamma radiation, which deposit their energy at a distance from the target. The aim of this study was to compare the response of different passive dosimetry systems in mixed radiation field induced by proton pencil beam inside anthropomorphic phantoms representing 5 and 10 years old children. Doses were measured in different organs with thermoluminescent (MTS-7, MTS-6 and MCP-N), radiophotoluminescent (GD-352 M and GD-302M), bubble and poly-allyl-diglycol carbonate (PADC) track detectors. Results show that RPL detectors are the less sensitive for neutrons than LiF TLDs and can be applied for in-phantom dosimetry of gamma component. Neutron doses determined using track detectors, bubble detectors and pairs of MTS-7/MTS-6 are consistent within the uncertainty range. This is the first study dealing with measurements on child anthropomorphic phantoms irradiated by a pencil scanning beam technique.


Assuntos
Imagens de Fantasmas , Terapia com Prótons/instrumentação , Prótons , Radiometria/instrumentação , Dosimetria Termoluminescente/instrumentação , Algoritmos , Antropometria , Criança , Pré-Escolar , Desenho de Equipamento , Raios gama/uso terapêutico , Humanos , Método de Monte Carlo , Nêutrons , Doses de Radiação , Radiação Ionizante , Cintilografia , Dosagem Radioterapêutica
4.
Spectrochim Acta A Mol Biomol Spectrosc ; 190: 259-267, 2018 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-28938170

RESUMO

Structural analyses of aroylhydrazones were performed by computational and spectroscopic methods (solid state NMR, 1 and 2D NMR spectroscopy, FT-IR (ATR) spectroscopy, Raman spectroscopy, UV-Vis spectrometry and spectrofluorimetry) in solid state and in solution. The studied compounds were N'-(2,3-dihydroxyphenylmethylidene)-3-pyridinecarbohydrazide (1), N'-(2,5-dihydroxyphenylmethylidene)-3-pyridinecarbohydrazide (2), N'-(3-chloro-2-hydroxy-phenylmethylidene)-3-pyridinecarbohydrazide (3), and N'-(2-hydroxy-4-methoxyphenyl-methylidene)-3-pyridinecarbohydrazide (4). Both in solid state and in solution, all compounds were in ketoamine form (form I, CONHNC), stabilized by intramolecular H-bond between hydroxyl proton and nitrogen atom of the CN group. In solid state, the CO group of 1-4 were involved in additional intermolecular H-bond between closely packed molecules. Among hydrazones studied, the chloro- and methoxy-derivatives have shown pH dependent and reversible fluorescence emission connected to deprotonation/protonation of salicylidene part of the molecules. All findings acquired by experimental methods (NMR, IR, Raman, and UV-Vis spectra) were in excellent agreement with those obtained by computational methods.

5.
Radiat Prot Dosimetry ; 168(2): 223-34, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25752758

RESUMO

Since autumn 2012, the European Radiation Dosimetry Group (EURADOS) has been developing its Strategic Research Agenda (SRA), which is intended to contribute to the identification of future research needs in radiation dosimetry in Europe. The present article summarises-based on input from EURADOS Working Groups (WGs) and Voting Members-five visions in dosimetry and defines key issues in dosimetry research that are considered important for the next decades. The five visions include scientific developments required towards (a) updated fundamental dose concepts and quantities, (b) improved radiation risk estimates deduced from epidemiological cohorts, (c) efficient dose assessment for radiological emergencies, (d) integrated personalised dosimetry in medical applications and (e) improved radiation protection of workers and the public. The SRA of EURADOS will be used as a guideline for future activities of the EURADOS WGs. A detailed version of the SRA can be downloaded as a EURADOS report from the EURADOS website (www.eurados.org).


Assuntos
Pesquisa Biomédica , Monitoramento de Radiação/normas , Proteção Radiológica , Radiação Ionizante , Radiometria/normas , Europa (Continente) , Guias como Assunto , Humanos , Doses de Radiação
6.
Med Phys ; 42(5): 2572-84, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25979049

RESUMO

PURPOSE: To characterize stray radiation around the target volume in scanning proton therapy and study the performance of active neutron monitors. METHODS: Working Group 9 of the European Radiation Dosimetry Group (EURADOS WG9-Radiation protection in medicine) carried out a large measurement campaign at the Trento Centro di Protonterapia (Trento, Italy) in order to determine the neutron spectra near the patient using two extended-range Bonner sphere spectrometry (BSS) systems. In addition, the work focused on acknowledging the performance of different commercial active dosimetry systems when measuring neutron ambient dose equivalents, H(∗)(10), at several positions inside (8 positions) and outside (3 positions) the treatment room. Detectors included three TEPCs--tissue equivalent proportional counters (Hawk type from Far West Technology, Inc.) and six rem-counters (WENDI-II, LB 6411, RadEye™ NL, a regular and an extended-range NM2B). Meanwhile, the photon component of stray radiation was deduced from the low-lineal energy transfer part of TEPC spectra or measured using a Thermo Scientific™ FH-40G survey meter. Experiments involved a water tank phantom (60 × 30 × 30 cm(3)) representing the patient that was uniformly irradiated using a 3 mm spot diameter proton pencil beam with 10 cm modulation width, 19.95 cm distal beam range, and 10 × 10 cm(2) field size. RESULTS: Neutron spectrometry around the target volume showed two main components at the thermal and fast energy ranges. The study also revealed the large dependence of the energy distribution of neutrons, and consequently of out-of-field doses, on the primary beam direction (directional emission of intranuclear cascade neutrons) and energy (spectral composition of secondary neutrons). In addition, neutron mapping within the facility was conducted and showed the highest H(∗)(10) value of ∼ 51 µSv Gy(-1); this was measured at 1.15 m along the beam axis. H(∗)(10) values significantly decreased with distance and angular position with respect to beam axis falling below 2 nSv Gy(-1) at the entrance of the maze, at the door outside the room and below detection limit in the gantry control room, and at an adjacent room (<0.1 nSv Gy(-1)). Finally, the agreement on H(∗)(10) values between all detectors showed a direct dependence on neutron spectra at the measurement position. While conventional rem-counters (LB 6411, RadEye™ NL, NM2-458) underestimated the H(∗)(10) by up to a factor of 4, Hawk TEPCs and the WENDI-II range-extended detector were found to have good performance (within 20%) even at the highest neutron fluence and energy range. Meanwhile, secondary photon dose equivalents were found to be up to five times lower than neutrons; remaining nonetheless of concern to the patient. CONCLUSIONS: Extended-range BSS, TEPCs, and the WENDI-II enable accurate measurements of stray neutrons while other rem-counters are not appropriate considering the high-energy range of neutrons involved in proton therapy.


Assuntos
Terapia com Prótons/métodos , Radiometria/métodos , Europa (Continente) , Nêutrons , Imagens de Fantasmas , Fótons , Terapia com Prótons/instrumentação , Prótons , Doses de Radiação , Radiometria/instrumentação , Análise Espectral/instrumentação , Análise Espectral/métodos , Água
8.
J Colloid Interface Sci ; 331(2): 295-301, 2009 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-19118839

RESUMO

The sorption of cationic surfactant hexadecyltrimethylammonium (HDTMA) onto the solid/liquid interfaces of different clinoptilolite rich tuffs (CT) is examined. Examined were CT from Serbia with 75% clinoptilolite, CT from Turkey with 70% clinoptilolite, and CT from Croatia with 60% clinoptilolite. The sorption of HDTMA cations increased in the following order: CT from Serbia>CT from Turkey>CT from Croatia. The maximum amounts of sorbed HDTMA cations, normalized with regard to external cation exchange capacities of tuffs, were 1.79, 1.70, and 1.14 for Serbian, Turkish, and Croatian CT. FTIR analysis of samples with the maximum amount of sorbed HDTMA cations showed that HDTMA chains on Serbian CT adopt mainly a stretched all-trans conformation, while at the surfaces of CT from Turkey and Croatia the amount of gauche conformations increased. The zeta potentials of CT samples with the maximum amount of sorbed HDTMA cations and the sorption of benzoate anions on these samples increased in the following order: CT from Turkey>CT from Serbia>CT from Croatia. It can be assumed that on the surface of CT from Turkey iron (hydr)oxide clusters or nanoparticles with positive surface sites are present, due to which the isoelectric point is sifted toward lower and the zeta potential toward higher values. Therefore, the sorption of benzoate anions on modified CT from Turkey is also higher.

9.
Radiat Prot Dosimetry ; 131(1): 80-6, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18757899

RESUMO

'Double dosimetry' i.e. measurement with two dosemeters, one located above the protective apron and one under has been recommended in interventional radiology (IR) to determine the effective dose to staff. Several algorithms have been developed to calculate the effective dose from the readings of the two dosemeters, but there is no international consensus on what is the best algorithm. In this work, a few of the most recently developed algorithms have been tested in typical IR conditions. The effective dose and personnel dosemeter readings were obtained experimentally by using thermoluminescent dosemeters in and on a Rando-Alderson phantom provided with a lead apron. In addition, the effective dose and personnel dosemeter readings were calculated by the Monte Carlo method for the same irradiation geometry. The results suggest that most of the algorithms overestimate effective dose in the selected IR conditions, but there is also a risk of underestimation by using the least conservative algorithms. Two of the algorithms seem to comply best with the chosen criteria of performance, i.e. no underestimation, minimum overestimation and close estimation of effective dose in typical IR conditions. However, it might not be justified to generalise the results. It is recommended that whenever personnel doses approach or exceed the dose limit, IR conditions should be further investigated and the possibility of over- or under-estimation of effective dose by the algorithm used should be considered.


Assuntos
Algoritmos , Corpo Clínico , Exposição Ocupacional , Doses de Radiação , Radiometria/instrumentação , Humanos , Método de Monte Carlo , Monitoramento de Radiação/instrumentação , Monitoramento de Radiação/métodos , Radiometria/métodos
10.
Radiat Prot Dosimetry ; 129(1-3): 333-9, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18483007

RESUMO

In interventional radiology, for an accurate determination of effective dose to the staff, measurements with two dosemeters have been recommended, one located above and one under the protective apron. Such 'double dosimetry' practices and the algorithms used for the determination of effective dose were reviewed in this study by circulating a questionnaire and by an extensive literature search. The results indicated that regulations for double dosimetry almost do not exist and there is no firm consensus on the most suitable calculation algorithms. The calculation of effective dose is mainly based on the single dosemeter measurements, in which either personal dose equivalent, directly, (dosemeter below the apron) or a fraction of personal dose equivalent (dosemeter above the apron) is taken as an assessment of effective dose. The most recent studies suggest that there might not be just one double dosimetry algorithm that would be optimum for all interventional radiology procedures. Further investigations in several critical configurations of interventional radiology procedures are needed to assess the suitability of the proposed algorithms.


Assuntos
Algoritmos , Exposição Ocupacional/análise , Doses de Radiação , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Radiologia Intervencionista/métodos , Humanos , Radiografia , Inquéritos e Questionários , Glândula Tireoide/diagnóstico por imagem
11.
Radiat Prot Dosimetry ; 125(1-4): 117-20, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17606480

RESUMO

A programme of harmonization of individual dosimetry quality control organized in the framework of a distributed metrology system is presented as seen from the experiences gained in Slovenia. As a part of the programme intercomparison of dosimetry services was organized and basic characteristics of dosimetry systems compared. Results are discussed with suggestions for further improvements of quality assurance.


Assuntos
Exposição Ocupacional/análise , Monitoramento de Radiação/normas , Proteção Radiológica/normas , Medição de Risco/normas , Dosimetria Termoluminescente/normas , Carga Corporal (Radioterapia) , Humanos , Internacionalidade , Exposição Ocupacional/prevenção & controle , Controle de Qualidade , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Eslovênia
12.
Radiat Prot Dosimetry ; 126(1-4): 198-205, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17522040

RESUMO

The dosimetric use of the chemical solution chlorobenzene-ethanol-trimethylpentane (CET) is based on the radiolytic formation of hydrochloric acid, which protonates a pH indicator thymolsulphonphthalein. On the basis of the CET solution, an accident and emergency personal dosemeter was designed allowing doses in the range 0.2-15 Gy can be measured. Radiation-chemical yields, G(HCl), for the CET system, and the responses of dosemeters in different neutron fields, ranging from 0.35 to 19.3 MeV mean energy neutrons, are summarised. The relation of G(HCl) to linear energy transfer (LET) of incident heavy charged particles is also evaluated on the basis of the previously published data. The response of the CET system to monoenergetic neutrons was calculated from the measured dependence of the G value upon LET of heavy charged particles and data about the LET distribution for monoenergetic neutrons. A very good agreement between this calculation and the experimental results was obtained. These results enable predictions of the response to be made in radiation fields with the known LET distributions.


Assuntos
Alcenos/efeitos da radiação , Clorobenzenos/efeitos da radiação , Etanol/efeitos da radiação , Nêutrons , Radiometria/instrumentação , Alcenos/química , Clorobenzenos/química , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Etanol/química , Concentração de Íons de Hidrogênio , Doses de Radiação , Radiometria/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
Radiat Prot Dosimetry ; 119(1-4): 300-5, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16735564

RESUMO

The responses of readings by the TL dosimetry system MR200 TL developed in-house and used at JSI and the TOLEDO TL system used at RBI are compared. Ten measurements at different doses ranging from 0.01 mSv to 5 Sv were carried out. A set of 36 dosemeters with three pellets of CaF2:Mn were irradiated in radiation fields of 137Cs and 60Co. Analysis of the measured results shows that at doses below 0.1 Sv, readers' outputs do not differ >5% from each other. At doses >1 Sv, the results obtained by the MR200 reader must be corrected with a known factor. Finally, the reproducibility of the results from the MR200 was tested.


Assuntos
Fluoreto de Cálcio/química , Fluoreto de Cálcio/efeitos da radiação , Dosimetria Termoluminescente/instrumentação , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Manganês/química , Manganês/efeitos da radiação , Teste de Materiais , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Dosimetria Termoluminescente/métodos
14.
Radiat Prot Dosimetry ; 119(1-4): 191-6, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16709712

RESUMO

Recently, two new types of 'tissue equivalent' thermoluminescent detectors (TLDs) have aroused attention: LiF:Mg,Cu,Na,Si and Li2B4O7:Cu,Ag,P. In this work the characteristics of both detectors were compared with the characteristics of the well-known type LiF:Mg,Ti detector, TLD-100. The following properties were investigated: the glow curve structures, relative sensitivity, batch homogeneity and uniformity, detection threshold, reproducibility of the response, linearity in the wide dose range and fading. Also, the energy dependence for medium and low energy X rays was determined in the range of mean energies between 33 and 116 keV. The results confirmed 'tissue equivalency' of both new types in the investigated range of photon energies. LiF:Mg,Cu,Na,Si detector has very high sensitivity (approximately 75 times higher than that of TLD-100) and is convenient for use in a very low range of doses. Li2B4O7:Cu,Ag,P detector shows some improvements in comparison with the previously prepared types of lithium borate. The most important is the five times higher sensitivity than that of TLD-100. This detector is also very promising, especially in medical dosimetry.


Assuntos
Boratos/química , Boratos/efeitos da radiação , Fluoretos/química , Fluoretos/efeitos da radiação , Compostos de Lítio/química , Compostos de Lítio/efeitos da radiação , Modelos Químicos , Dosimetria Termoluminescente/instrumentação , Dosimetria Termoluminescente/métodos , Simulação por Computador , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Teste de Materiais , Fósforo/química , Fósforo/efeitos da radiação , Doses de Radiação
15.
Radiat Prot Dosimetry ; 121(2): 191-4, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16410289

RESUMO

Environmental gamma radiation monitoring established in Slovenia consists of a network of multifunctional gamma monitors (MFMs) based on pairs of Geiger-Müller counters and a network of measuring sites with high-sensitive thermoluminiscence dosemeters. The measuring points are evenly spread across Slovenia, located at the meteorological stations and more densely on additional locations around the Krsko NPP. The MFM network has a 2-fold function with one sensor used for the purpose of early warning system in near surroundings of the NPP and the other, more sensitive, for natural radiation monitoring. The paper summarises activities to establish quality assurance of the environmental gamma radiation measurements in Slovenia, with a critical view of the results in comparison with the international standards and recommendations. While the results of linearity and energy dependence tests were satisfying, on-field intercomparison showed that the inherent signal of one of the monitors (MFM) has to be taken into account in the range of environmental background radiation.


Assuntos
Raios gama , Garantia da Qualidade dos Cuidados de Saúde/métodos , Monitoramento de Radiação , Contaminação Radioativa do Ar , Humanos , Garantia da Qualidade dos Cuidados de Saúde/normas , Controle de Qualidade , Radiometria , Eslovênia , Dosimetria Termoluminescente
16.
Radiat Prot Dosimetry ; 106(3): 253-6, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-14690327

RESUMO

The aim of this work was to determine energy dependence characteristics in terms of values of the personal dose equivalent, HP(10). The following types of thermoluminescent detectors (TLDs) were investigated: (a) two new types based on lithium borate, Li2B4O7:Cu,In and Li2B4O7:Cu,In,Ag; (b) two types based on the highly sensitive material LiF:Mg,Cu,P, TLD-700H and GR 200A; (c) two well-known types of LiF:Mg,Ti detector, TLD-100 and TLD-700 and (d) highly sensitive Al2O3:C detectors. TLDs previously calibrated with 137Cs gamma rays were simultaneously irradiated with X ray beams in the range of mean energies between 33 and 116 keV. The irradiations were performed with detectors in polymethyl methacrylate (PMMA) holders placed on a 30 cm x 30 cm x 15 cm water phantom with PMMA walls (ISO phantom). Measured energy responses were compared with calculated data for HP(10) values. The results confirmed the satisfactory tissue equivalent characteristics of all investigated TLDs except Al2O3:C, which (due to its large energy dependence) is suitable for personal dosimetry only with an appropriate filter.


Assuntos
Dosimetria Termoluminescente/instrumentação , Dosimetria Termoluminescente/métodos , Boratos , Calibragem , Radioisótopos de Césio , Raios gama , Radioisótopos de Irídio , Compostos de Lítio , Imagens de Fantasmas , Fótons , Polimetil Metacrilato , Radiometria , Dosagem Radioterapêutica , Água , Raios X
17.
Radiat Prot Dosimetry ; 100(1-4): 437-42, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12382916

RESUMO

The aim of this work was to determine important dosimetric characteristics of several types of the most interesting tissue-equivalent thermoluminescent detectors (TLDs). Special attention was given to the determination of energy dependence for medium and low energy X rays. The following types of TLDs were investigated: (a) two new types based on lithium borate: Li2B4O7:Cu,In and Li,B4O7:Cu,In,Ag; (b) two types of the recently developed highly sensitive LiF:Mg,Cu,P material: TLD-700H and GR 200A and (c) two well known types of LiF:Mg,Ti detectors: TLD-100 and TLD-700. In order to determine their photon energy response characteristics, TLDs previously calibrated with 137Cs gamma rays were simultaneously irradiated with X ray beams in the range of effective energies between 33 and 116 keV. Measured energy responses (relative to air), normalised to those to 137Cs photons were compared with calculated data. Although the deviations of the measured data from the 'theoretical' predictions are different for all the investigated TLDs, there is no large difference in 'tissue-equivalency' between them.


Assuntos
Dosimetria Termoluminescente/métodos , Boratos/química , Boratos/efeitos da radiação , Fluoretos/química , Fluoretos/efeitos da radiação , Raios gama , Temperatura Alta , Humanos , Compostos de Lítio/química , Compostos de Lítio/efeitos da radiação , Medições Luminescentes , Metais/química , Radioquímica , Sensibilidade e Especificidade , Dosimetria Termoluminescente/estatística & dados numéricos , Raios X
18.
Radiat Prot Dosimetry ; 98(4): 407-16, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12120668

RESUMO

The alkaline comet assay was employed in the assessment of DNA damage in leukocytes of a worker incidently exposed to gamma radiation (221 mSv, 60Co source). The comet tail lengths and tail moments were studied. By using the alkaline comet assay immediately after accidental exposure a high level of DNA damage was recorded. The highest levels of DNA damage were recorded one day and one week after the radiation incident. Later on, a decrease in both comet parameters was observed. Although the level of DNA damage was diminished during a one year period, it was still elevated compared to normal values recorded in leukocytes of a healthy, unexposed person. The results obtained indicate that the alkaline comet assay is a rapid and sensitive microdosimetric technique and is suitable for in vivo human biomonitoring, especially in cases of incidental exposure to ionising radiation.


Assuntos
Ensaio Cometa/métodos , Dano ao DNA , Raios gama , Leucócitos/efeitos da radiação , Lesões por Radiação/diagnóstico , Liberação Nociva de Radioativos , Radiometria/métodos , Radioisótopos de Cobalto , Humanos , Masculino , Pessoa de Meia-Idade
19.
Phys Med Biol ; 42(7): 1335-49, 1997 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-9253043

RESUMO

Several types of thermoluminescent dosimeters (LiF:Mg, Ti, Al2O3:Mg,Y and CaF2:Mn) were irradiated at different depths in a water phantom placed at a distance of 2.5 m from a panoramic 60Co source. Detectors were encapsulated in Plexiglas holders with a wall thickness of 0.5 cm. Reference dosimetry was carried out using a Fricke dosimeter and an ionization chamber. The experimental data were compared with the predictions of the general cavity theory for gamma ray spectra at different depths of water. The suitability of parameters of the cavity theory proposed by different authors was evaluated in the analysis of the experimental results. The results show that there is no need for any modification to the original and simple Burlin expression which gives very good agreement with the experimental values.


Assuntos
Radioisótopos de Cobalto , Modelos Teóricos , Imagens de Fantasmas , Dosagem Radioterapêutica , Raios gama , Medições Luminescentes , Água
20.
Mutat Res ; 324(1-2): 35-41, 1994 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-7515468

RESUMO

We reported earlier that human cervical carcinoma HeLa cells exposed to 30 fractions of 0.5 Gy gamma-rays became resistant to cisplatin, methotrexate and vincristine, but retained the same sensitivity to gamma-rays and ultraviolet light. The aim of this study was to examine whether a small number of gamma-ray fractions, with a lower daily dose, may also change the sensitivity of preirradiated cells to different cytotoxic drugs. Using the modified MTT staining procedure, we found that cells preirradiated with 5 or 10 daily fractions of only 0.17 Gy gamma-rays did not alter their sensitivity to mitomycin, cisplatin, methotrexate, 5-fluorouracil, etoposide and doxorubicin. However, 10 fractions of gamma-rays induced resistance to vincristine and vinblastine. Our immunocytochemical experiments using monoclonal antibody JSB-1 show that the plasma membrane P-glycoprotein is involved in the induced resistance to Vinca alkaloids.


Assuntos
Antineoplásicos/farmacologia , Proteínas de Transporte/genética , Resistência a Medicamentos/genética , Resistência a Medicamentos/efeitos da radiação , Glicoproteínas de Membrana/genética , Alcaloides de Vinca/farmacologia , Membro 1 da Subfamília B de Cassetes de Ligação de ATP , Relação Dose-Resposta a Droga , Ensaios de Seleção de Medicamentos Antitumorais , Raios gama , Expressão Gênica , Células HeLa/efeitos da radiação , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...