Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Echocardiography ; 35(1): 64-70, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29071795

RESUMO

OBJECTIVES: The aim of this study was to evaluate the hemodynamic performance of a sutureless bioprosthesis under high workload at mid-term follow-up. METHODS: Thirty-two patients who underwent isolated aortic valve replacement with a Perceval sutureless bioprosthesis with a minimum follow-up of 1 year were enrolled in this study. S size prosthesis was deployed in 10 patients (31.3%), M size in 9 (28.1%), L size in 8 (25%) and XL size in 5 (15.6%). Effective orifice area (EOA), EOA index (EOAi), and transvalvular gradients were assessed at rest and during dobutamine stress echocardiography (DSE) a median of 19.5 months after surgery. RESULTS: Dobutamine stress echocardiography (DSE) significantly increased heart rate, stroke volume, ejection fraction, and transvalvular gradients (peak gradient, 24.0 ± 7.6 vs 38.7 ± 13.6 mm Hg, P < .001; mean gradient, 12.6 ± 4.2 vs 19.8 ± 8.3, P < .001). When compared to baseline, estimated valve areas significantly increased at follow-up (EOA, 1.48 ± 0.46 vs 2.06 ± 0.67, P < .001; EOAi, 0.84 ± 0.26 vs 1.17 ± 0.37, P < .001). Mean percentage increase in EOAi was 40.3% ± 28.0%. S size prostheses had the highest increase in EOA1, but the difference was not significant (S 46.0% ± 27.5% vs M 45.4% ± 34.5% vs L 32.7% ± 26.4% vs XL 32.1% ± 20.5%, P = .66). Severe patient-prosthesis mismatch (EOAi ≤ 0.65 cm2 /m2 ) was present at rest in 8 patients (25%), but only in one patient (3.1%) during DSE. CONCLUSIONS: The Perceval sutureless bioprosthesis demonstrated good hemodynamics at rest and under high workload. The significant increase in EOAi during DSE suggests the potential advantages of Perceval sutureless bioprostheses in case of small aortic annulus or when patient-prosthesis mismatch is anticipated.


Assuntos
Bioprótese , Ecocardiografia sob Estresse/métodos , Próteses Valvulares Cardíacas , Hemodinâmica/fisiologia , Complicações Pós-Operatórias/diagnóstico por imagem , Procedimentos Cirúrgicos sem Sutura/métodos , Idoso , Feminino , Seguimentos , Valvas Cardíacas/diagnóstico por imagem , Valvas Cardíacas/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/fisiopatologia
2.
J Am Soc Echocardiogr ; 25(10): 1099-105, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22898243

RESUMO

BACKGROUND: Successful mitral valve surgical repair, decreasing volume overload, has been shown to provide reverse left ventricular (LV) and/or left atrial remodeling in most patients. Percutaneous mitral valve repair with the MitraClip system (Abbott, Abbott Park, IL) has been associated with favorable clinical outcomes in patients with mitral regurgitation at high risk of surgery. However, specific data on left cardiac chambers reverse remodeling after such procedures are limited. METHODS: This was a prospective observational study of consecutive patients at high risk of surgery, with moderate-to-severe or severe mitral regurgitation undergoing MitraClip system implantation. Follow-up echocardiography was performed at 6 months. The evaluated parameters were the LV end-diastolic and end-systolic volume indexes, LV sphericity index, LV ejection fraction, and left atrial volume index. Reverse LV remodeling was defined as a decrease of 10% in the LV end-diastolic volume index. RESULTS: The study population included 44 patients: 14 with degenerative and 30 with functional mitral regurgitation. At 6 months of follow-up, significant reductions in the median and interquartile range of the sphericity index (from 0.57 [interquartile range 0.54-0.62] to 0.54 [interquartile range 0.50-0.58]; P < .001), LV end-diastolic volume index (from 79.4 mL/m(2) [interquartile range 63.0-102.2] to 60.7 mL/m(2) [50.8-84.4]; P < .001), and LV end-systolic volume index (from 49.3 mL/m(2) [interquartile range 28.2-70.5] to 28.9 mL/m(2) [interquartile range 22.2-55.8]; P < .001) were observed. The LV ejection fraction improved significantly (from 38.0% [interquartile range 30.0-55.0%] to 46.0% [interquartile range 35.0-58.0%]; P < .001) from baseline to 6 months. Minor differences in the left atrial volume index were observed. Reverse remodeling, according to the specified definition, was observed in 77.3% of the patients. CONCLUSIONS: The present study reports positive LV reshape effects after mitral valve repair with the MitraClip system, showing significant improvements in LV size and function.


Assuntos
Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Dispositivo para Oclusão Septal , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/prevenção & controle , Idoso , Feminino , Humanos , Masculino , Insuficiência da Valva Mitral/complicações , Resultado do Tratamento , Ultrassonografia , Disfunção Ventricular Esquerda/etiologia , Remodelação Ventricular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...