Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Hypertension ; 74(1): 117-129, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31132954

RESUMO

Aortic pulse wave velocity is a worldwide accepted index to evaluate aortic stiffness and can be assessed noninvasively by several methods. This study sought to determine if commonly used noninvasive devices can all accurately estimate aortic pulse wave velocity. Pulse wave velocity was estimated in 102 patients (aged 65±13 years) undergoing diagnostic coronary angiography with 7 noninvasive devices and compared with invasive aortic pulse wave velocity. Devices evaluating carotid-femoral pulse wave velocity (Complior Analyse, PulsePen ET, PulsePen ETT, and SphygmoCor) showed a strong agreement between each other ( r>0.83) and with invasive aortic pulse wave velocity. The mean difference ±SD with the invasive pulse wave velocity was -0.73±2.83 m/s ( r=0.64) for Complior-Analyse: 0.20±2.54 m/s ( r=0.71) for PulsePen-ETT: -0.04±2.33 m/s ( r=0.78) for PulsePen ET; and -0.61±2.57 m/s ( r=0.70) for SphygmoCor. The finger-toe pulse wave velocity, evaluated by pOpmètre, showed only a weak relationship with invasive aortic recording (mean difference ±SD =-0.44±4.44 m/s; r=0.41), and with noninvasive carotid-femoral pulse wave velocity measurements ( r<0.33). Pulse wave velocity estimated through a proprietary algorithm by BPLab (v.5.03 and v.6.02) and Mobil-O-Graph showed a weaker agreement with invasive pulse wave velocity compared with carotid-femoral pulse wave velocity (mean difference ±SD =-0.71±3.55 m/s, r=0.23; 1.04±2.27 m/s, r=0.77; and -1.01±2.54 m/s, r=0.71, respectively), revealing a negative proportional bias at Bland-Altman plot. Aortic pulse wave velocity values provided by BPLab and Mobil-O-Graph were entirely dependent on age-squared and peripheral systolic blood pressure (cumulative r2=0.98 and 0.99, respectively). Thus, among the methods evaluated, only those assessing carotid-femoral pulse wave velocity (Complior Analyse, PulsePen ETT, PulsePen ET, and SphygmoCor) appear to be reliable approaches for estimation of aortic stiffness.


Assuntos
Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Hemodinâmica/fisiologia , Análise de Onda de Pulso/métodos , Rigidez Vascular/fisiologia , Idoso , Velocidade do Fluxo Sanguíneo/fisiologia , Determinação da Pressão Arterial/métodos , Doenças Cardiovasculares/fisiopatologia , Estudos de Coortes , Estenose Coronária/fisiopatologia , Humanos , Itália , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fluxo Pulsátil/fisiologia , Sensibilidade e Especificidade , Índice de Gravidade de Doença
2.
Am J Hypertens ; 31(1): 80-88, 2017 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-29059329

RESUMO

BACKGROUND: Aortic pulse wave velocity (PWV) is an indirect index of arterial stiffness and an independent cardiovascular risk factor. Consistency of PWV assessment over time is thus an essential feature for its clinical application. However, studies providing a comparative estimate of the reproducibility of PWV across different noninvasive devices are lacking, especially in the elderly and in individuals at high cardiovascular risk. METHODS: Aimed at filling this gap, short-term repeatability of PWV, estimated with 6 different devices (Complior Analyse, PulsePen-ETT, PulsePen-ET, SphygmoCor Px/Vx, BPLab, and Mobil-O-Graph), was evaluated in 102 high cardiovascular risk patients hospitalized for suspected coronary artery disease (72 males, 65 ± 13 years). PWV was measured in a single session twice, at 15-minute interval, and its reproducibility was assessed though coefficient of variation (CV), coefficient of repeatability, and intraclass correlation coefficient. RESULTS: The CV of PWV, measured with any of these devices, was <10%. Repeatability was higher with cuff-based methods (BPLab: CV = 5.5% and Mobil-O-Graph: CV = 3.4%) than with devices measuring carotid-femoral PWV (Complior: CV = 8.2%; PulsePen-TT: CV = 8.0%; PulsePen-ETT: CV = 5.8%; and SphygmoCor: CV = 9.5%). In the latter group, PWV repeatability was lower in subjects with higher carotid-femoral PWV. The differences in PWV between repeated measurements, except for the Mobil-O-Graph, did not depend on short-term variations of mean blood pressure or heart rate. CONCLUSIONS: Our study shows that the short-term repeatability of PWV measures is good but not homogenous across different devices and at different PWV values. These findings, obtained in patients at high cardiovascular risk, may be relevant when evaluating the prognostic importance of PWV.


Assuntos
Aorta/fisiologia , Análise de Onda de Pulso/instrumentação , Análise de Onda de Pulso/estatística & dados numéricos , Rigidez Vascular/fisiologia , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Pressão Sanguínea , Determinação da Pressão Arterial , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/fisiopatologia , Artérias Carótidas/fisiopatologia , Feminino , Artéria Femoral/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Risco
4.
Vasc Health Risk Manag ; 12: 305-11, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27536125

RESUMO

In occidental countries, peripheral arterial disease (PAD) is an important health issue; however, most subjects are asymptomatic (~50%) and therefore undiagnosed and untreated. Current guidelines recommend screening for PAD in primary care setting using ankle brachial index (ABI) in all patients with cardiovascular risks. This is, however, not performed strictly because the standard Doppler method is cumbersome and time-consuming. Here, we evaluate the accuracy and reproducibility of ABI measurements obtained by an improved automated oscillometric device, the MESI ABPI MD(®) device, and the standard Doppler method. ABI was measured in random order in a general practice with Doppler probes by two operators separately (ABI_dop) and twice with the MESI ABPI MD device (ABI_mesi). ABI_dop was calculated dividing the highest systolic blood pressure from both tibial and dorsalis pedis arteries by the highest systolic blood pressure of both brachial arteries. ABI_mesi was obtained automatically with simultaneous measurements on three extremities. According to ABI_dop, PAD was present in 10% of the 136 screened subjects (68.2±7.4 years). Interoperator coefficient of variation was 5.5% for ABI_dop, while the intrasubject coefficient of variation for ABI_mesi was 3.0%. ABI_mesi was correlated with ABI_dop (R=0.61, P<0.0001). The difference between the two techniques was 0.06±0.14 with ABI_mesi providing slightly higher values (P<0.0001) and negligible bias across the range (R=0.19, P<0.0001). Therefore, ABI_mesi ≤1 had a sensitivity of 85% and specificity of 96% to detect ABI_dop ≤0.9 and hence PAD. Doppler measurements took seven times longer than MESI ABPI MD measurements to be performed. In conclusion, MESI improved automated oscillometric method and offered a faster and repeatable measurement of ABI with only a small, clinically irrelevant overestimation of ABI value. The tested MESI ABPI MD-improved oscillometric system can be used as a screening tool for patients in general practice and would enable family doctors to comply with current guidelines for PAD.


Assuntos
Índice Tornozelo-Braço/instrumentação , Índice Tornozelo-Braço/métodos , Pressão Sanguínea , Doença Arterial Periférica/diagnóstico , Ultrassonografia Doppler , Idoso , Automação , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Oscilometria/instrumentação , Doença Arterial Periférica/fisiopatologia , Pletismografia/instrumentação , Valor Preditivo dos Testes , Distribuição Aleatória , Reprodutibilidade dos Testes , Fatores de Tempo , Estudos de Tempo e Movimento
5.
J Clin Monit Comput ; 27(6): 613-9, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23681924

RESUMO

The Complior device (Alam Medical, France) has contributed to the rise of arterial stiffness as a measure of cardiovascular risk. In its latest version (Complior Analyse) the sensor records pressure instead of distension waveforms thus allowing the measurement of central pressure and pulse wave analysis. The aim of our study was to verify that the new sensor measures pressure waveforms accurately in both time and frequency domain. Invasive and non-invasive signals were recorded simultaneously at the radial artery and compared in the frequency and time domain in haemodynamically stable intensive care unit patients. Twelve patients entered the study (8 men, 4 women, mean age 69 ± 17 years). Heart rate was 90 ± 15 bpm, systolic blood pressure 133 ± 19 mmHg and diastolic blood pressure 68 ± 15 mmHg. There was no statistical difference in the amplitude of harmonics between the invasive signal and Complior signal. When superimposing waveforms in the time domain, there was a small difference in the form factor (4.2 ± 2.8 %) and in the absolute area between the 2 waveforms (3.3 ± 1.7 mmHg·s(-1)). These differences were of the same magnitude as the beat-to-beat variation of the form factor (3.3 %) and of the absolute area (3.1 mmHg·s(-1)), respectively. The second systolic peak was detectable in 4 subjects, with no statistical difference between invasive and non-invasive values. The new pressure sensor of the Complior Analyse device recorded pressure waveforms accurately and could be used to perform pressure wave analysis.


Assuntos
Determinação da Pressão Arterial/instrumentação , Rigidez Vascular , Adulto , Idoso , Idoso de 80 Anos ou mais , Cateterismo Periférico , Cuidados Críticos , Diástole , Desenho de Equipamento , Feminino , Frequência Cardíaca , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/instrumentação , Estudos Prospectivos , Artéria Radial/patologia , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Sístole
6.
Calcif Tissue Int ; 83(2): 112-20, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18612580

RESUMO

Arterial calcification leading to increased arterial stiffness, a powerful risk factor for cardiovascular disease, may underlie the association of osteoporosis with cardiovascular disease in postmenopausal women. Osteoprotegerin (OPG), an indirect inhibitor of osteoclastogenesis, may be involved in arterial calcification. We examined relationships between calcification of subclinical atherosclerotic plaque and arterial stiffness with bone mineral density (BMD) and OPG in a group of 54 postmenopausal women referred for routine osteoporosis screening by dual-energy X-ray absorptiometric scanning of the lumbar spine and hip. Presence of calcified and noncalcified plaque in carotid and femoral arteries was examined using ultrasonography. Pulse wave velocity (PWV), a measure of arterial stiffness, was determined by sequential tonometry over the carotid and femoral region. Fifty-nine percent of osteoporotic women had calcified (echogenic) plaque at one or more sites compared with 42% and 20% for women with osteopenia and normal BMD, respectively (P = 0.04). There was a significant negative correlation between PWV and hip BMD (r = -0.35, P = 0.01), which remained significant when age, mean arterial pressure, and serum lipids were taken into account (P = 0.05). No significant relationships were observed between serum concentrations of OPG and lumbar spine or total hip BMD or with the number of arterial sites with calcified or noncalcified plaque. However, there was a strong correlation between OPG and PWV (r = 0.44, P = 0.001), which remained significant when adjusted for age (P = 0.01). These findings suggest that decreased BMD is associated with arterial calcification and stiffening and raise the possibility that OPG is a marker of arterial stiffening, independent of any association with BMD.


Assuntos
Aterosclerose/patologia , Densidade Óssea/fisiologia , Calcinose/patologia , Programas de Rastreamento/métodos , Osteoporose Pós-Menopausa/diagnóstico , Osteoprotegerina/sangue , Adulto , Idoso , Idoso de 80 Anos ou mais , Aterosclerose/sangue , Aterosclerose/diagnóstico por imagem , Biomarcadores/metabolismo , Calcinose/sangue , Calcinose/diagnóstico por imagem , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/patologia , Feminino , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/metabolismo , Humanos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/metabolismo , Pessoa de Meia-Idade , Radiografia , Ultrassonografia
7.
IEEE Trans Biomed Eng ; 54(12): 2268-75, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18075043

RESUMO

Cardiovascular disease (CVD) is currently the biggest single cause of mortality in the developed world, hence, the early detection of its onset is vital for effective prevention therapies. Aortic stiffness as measured by aortic pulse wave velocity (PWV) has been shown to be an independent predictor of CVD, however, the measurement of PWV is complex and time consuming. Recent studies have shown that pulse contour characteristics depend on arterial properties such as arterial stiffness. This paper presents a method for estimating PWV from the digital volume pulse (DVP), a waveform that can be rapidly and simply acquired by measuring the transmission of infra-red light through the finger pulp. PWV and DVP were measured on 461 subjects attending a clinic in South East London. Techniques for extracting features from the DVP contour based on physiology and information theory were compared. Low and high stiffness were defined according to a threshold level of PWV chosen to be 10 m/s. Using a support vector machine-based classifier, it is possible to achieve high overall classification rates on unseen data. Further, the use of support vector regression techniques lead to a direct real-valued estimate of PWV which outperforms previous methods based on multilinear regression. We, therefore, conclude that support vector machine-based classification and regression techniques provide effective prediction of arterial stiffness from the simple measurement of the digital volume pulse. This technique could be usefully employed as a cheap and effective CVD screening technique for use in general practice clinics.


Assuntos
Artérias/fisiopatologia , Doenças Cardiovasculares/diagnóstico , Diagnóstico por Computador/métodos , Fotopletismografia/métodos , Processamento de Sinais Assistido por Computador , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Inteligência Artificial , Volume Sanguíneo , Doenças Cardiovasculares/fisiopatologia , Elasticidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reconhecimento Automatizado de Padrão/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
J Am Coll Cardiol ; 48(9): 1846-50, 2006 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-17084260

RESUMO

OBJECTIVES: The purpose of this study was to compare 3 non-invasive techniques for assessment of endothelial function in adults and children and evaluate their utility in acute inflammation. BACKGROUND: Endothelial dysfunction is a key early event in pre-clinical atherosclerosis. Flow-mediated dilation (FMD), although the established technique, is expensive and technically demanding. Measurements of vascular responses to inhaled salbutamol by pulse wave analysis (PWA) or pulse contour analysis (PCA) are potential alternatives. METHODS: Sixteen adults (mean age 28 years, range 18 to 39) and 16 children (mean age 13 years, range 7 to 17) underwent concurrent vascular function testing on 2 occasions with ultrasound, PWA, and PCA. Eighteen men were also studied before and after typhoid vaccination. RESULTS: Reproducibility of FMD was high in adults and children (coefficient of variation [CV] = 7.1 and 6.3, respectively). Salbutamol responses were more variable with PWA (adults CV = 11.5, children CV = 17.1) and PCA particularly in children (adults CV = 18.2, children CV = 36.3). Flow-mediated dilation (p < 0.001) and PWA with salbutamol (p = 0.03) responses fell after typhoid vaccination, and PCA (p = 0.7) was unchanged. CONCLUSIONS: Vascular dysfunction during acute inflammation can be measured by FMD and by PWA with salbutamol. Flow-mediated dilation is less variable than PWA. Variability of PCA makes this technique currently unsuited to serial measures of endothelial function in children. Flow-mediated dilation remains the most reproducible method.


Assuntos
Endotélio Vascular/fisiologia , Fluxo Pulsátil/fisiologia , Adolescente , Adulto , Velocidade do Fluxo Sanguíneo/efeitos dos fármacos , Velocidade do Fluxo Sanguíneo/fisiologia , Artéria Braquial/efeitos dos fármacos , Artéria Braquial/fisiologia , Criança , Endotélio Vascular/efeitos dos fármacos , Feminino , Humanos , Masculino , Nitroglicerina/farmacologia , Vacinas Tíficas-Paratíficas/farmacologia , Vasodilatação/efeitos dos fármacos , Vasodilatação/fisiologia
9.
Hypertension ; 48(3): 404-10, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16908758

RESUMO

Stiffness of large elastic arteries is elevated in subjects with hypertension, an effect that could potentially be explained by increased distending pressure. We examined effects of an acute change in blood pressure on carotid-femoral pulse wave velocity and carotid artery distensibility (inversely related to stiffness) in normotensive control subjects (n=20, mean age 42) with mean arterial pressure (MAP) 84+/-1.7 mm Hg (mean+/-SE) and subjects with essential hypertension (n=20, mean age 45, MAP 104+/-2.0 mm Hg). Normotensive subjects received intravenous nitroglycerin (NTG) and angiotensin II to lower/increase blood pressure. Hypertensive subjects received NTG to lower blood pressure. Pulse wave velocity was 24% (95% CI: 12% to 35%) higher and carotid distensibility 47% (95% CI: 32% to 63%) lower in hypertensive subjects compared with controls. In normotensive subjects, acute changes in blood pressure produced expected changes in stiffness. However, in hypertensive subjects, despite reducing MAP by 22 mm Hg to the same level as in normotensive subjects, there was no detectable reduction in arterial stiffness: pulse wave velocity remained 24% (95% CI: 10% to 38%) higher and carotid distensibility 48% (95% CI: 31% to 63%) lower in hypertensive compared with normotensive subjects. Because blood pressure-independent effects of NTG are, if anything, to reduce stiffness, these results indicate that elevated carotid and aortic stiffness in hypertensive subjects is not explained by elevated blood pressure but relates to structural change in the arterial wall.


Assuntos
Pressão Sanguínea/efeitos dos fármacos , Artérias Carótidas/fisiopatologia , Artéria Femoral/fisiopatologia , Hipertensão/tratamento farmacológico , Hipertensão/fisiopatologia , Nitroglicerina/uso terapêutico , Vasodilatadores/uso terapêutico , Adulto , Velocidade do Fluxo Sanguíneo , Estudos de Casos e Controles , Complacência (Medida de Distensibilidade) , Diástole , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pulso Arterial , Fatores de Tempo
10.
J Hypertens ; 24(8): 1449-56, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16877944

RESUMO

Analysis of the contour of the peripheral pulse to assess arterial properties was first described in the nineteenth century. With the recognition of the importance of arterial stiffness there has been a resurgence of interest in pulse wave analysis, particularly the analysis of the radial pressure pulse acquired using a tonometer. An alternative technique utilizes a volume pulse. This may conveniently be acquired optically from a finger (digital volume pulse). Although less widely used, this technique deserves further consideration because of its simplicity and ease of use. As with the pressure pulse, the contour of the digital volume pulse is sensitive to changes in arterial tone induced by vasoactive drugs and is influenced by ageing and large artery stiffness. Measurements taken directly from the digital volume pulse or from its second derivative can be used to assess these properties. This review describes the background to digital volume pulse contour analysis, how the technique relates to contour analysis of the pressure pulse, and current and future applications.


Assuntos
Dedos/irrigação sanguínea , Fotopletismografia , Pulso Arterial , Pressão Sanguínea/fisiologia , Endotélio Vascular/fisiologia , Dedos/fisiologia , Humanos , Manometria/métodos , Manometria/tendências , Fotopletismografia/métodos , Fotopletismografia/tendências , Pulso Arterial/métodos , Pulso Arterial/tendências , Processamento de Sinais Assistido por Computador , Resistência Vascular/fisiologia , Sistema Vasomotor/fisiologia
11.
Am J Hypertens ; 19(1): 19-24, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16461185

RESUMO

BACKGROUND: Activity of the renin-angiotensin-aldosterone system is thought to play a major role in determining blood pressure (BP) and target organ damage such as left ventricular hypertrophy. In Afro-Caribbean subjects, however, hypertension tends to be more severe despite lower plasma renin activity. We investigated whether this might be due to a different relation between aldosterone and renin in Afro-Caribbean compared to white subjects. METHODS: Plasma aldosterone and renin activity were assessed in the morning after 15 min seated in 383 hypertensive subjects of Afro-Caribbean or white ethnicity (61% Afro-Caribbean, 83% on treatment) attending a hypertension clinic in London, UK. Left ventricular mass index (LVMI) was assessed by echocardiography in 276 subjects. RESULTS: Plasma renin activity was lower in Afro-Caribbean compared to white subjects (0.4 [0.3-1.0] v 1.4 [0.5-3.4] ng/mL/h, medians [interquartile range], P < .0001). Despite this, aldosterone was higher in Afro-Caribbean compared to white subjects (8.0 [6.1-12.6] v 7.4 [2.3-17.1] ng/dL, medians [interquartile range], P < .01). The LVMI corrected for sex and BP was higher in Afro-Caribbean than in white subjects. In Afro-Caribbean but not in white subjects LVMI was independently correlated with plasma aldosterone (standardized regression coefficient, beta= 0.25, P < .001). CONCLUSIONS: In Afro-Caribbean hypertensive subjects in London, plasma aldosterone is elevated despite lower renin and may contribute to increased severity of hypertension and left ventricular hypertrophy in Afro-Caribbean compared to white subjects.


Assuntos
Aldosterona/sangue , População Negra , Hipertensão/etnologia , Hipertrofia Ventricular Esquerda/etnologia , Renina/sangue , Adulto , Idoso , Aldosterona/fisiologia , Pressão Sanguínea , Região do Caribe/etnologia , Ecocardiografia , Feminino , Humanos , Hipertensão/sangue , Hipertensão/complicações , Hipertensão/fisiopatologia , Hipertrofia Ventricular Esquerda/sangue , Hipertrofia Ventricular Esquerda/etiologia , Hipertrofia Ventricular Esquerda/fisiopatologia , Masculino , Pessoa de Meia-Idade , Radioimunoensaio , Renina/fisiologia , Sistema Renina-Angiotensina/fisiologia , População Branca
12.
J Hypertens ; 23(7): 1391-6, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15942462

RESUMO

OBJECTIVE: An association between birth weight and blood pressure has been reported in many studies, but the strength of this association has been disputed. Birth weight could, however, be associated with alterations in the proximal arterial tree that have little effect on blood pressure. The objective of this study was to examine the relationship between birth weight and characteristics of the proximal arterial tree determined by pulse wave analysis. METHODS: An optically derived digital volume pulse was used to obtain indices of pressure wave reflection (reflection index; RI) determined by characteristics of small/medium sized arteries and of large artery stiffness (stiffness index; SI) in healthy young adults (n = 220, 111 women, aged 16-26 years). Birth weight was obtained from maternal recall. RESULTS: Diastolic blood pressure was significantly correlated with birth weight (P < 0.001) but birth weight accounted for only 5% of the variance in diastolic blood pressure. RI was significantly correlated with birth weight in women (r = -0.33, P < 0.001) but not in men, and there was a significant interaction between birth weight and sex (P < 0.001). SI was significantly independently correlated with birth weight in both men and women (r = -0.41 and -0.49, each P < 0.0001) and birth weight accounted for 17% of the overall (men and women) variance in SI. CONCLUSIONS: These results suggest a close association between birth weight and characteristics of the arterial tree proximal to resistance vessels in young adults and a sex-specific association with characteristics influencing arterial pressure wave reflection.


Assuntos
Peso ao Nascer , Pressão Sanguínea/fisiologia , Fluxo Pulsátil/fisiologia , Adolescente , Adulto , Artérias/fisiologia , Complacência (Medida de Distensibilidade) , Feminino , Humanos , Masculino , Pletismografia , Valor Preditivo dos Testes , Pulso Arterial , Análise de Regressão , Fatores Sexuais , Resistência Vascular
13.
Hypertension ; 45(2): 222-6, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15642772

RESUMO

Carotid-femoral pulse wave velocity (PWV), a measure of arterial stiffness, is determined from the time taken for the arterial pulse to propagate from the carotid to the femoral artery. Propagation time is measured variously from the foot of the waveform or point of maximum upslope. We investigated whether these methods give comparable values of PWV at rest, during beta-adrenergic stimulation, and pacing-induced tachycardia. In subjects at rest (n=43), values obtained using the foot-to-foot method (SphygmoCor system) were 1.7+/-0.75 m/s (mean+/-SD) greater than those obtained using the maximum slope (Complior system) at a mean value of 12 m/s. Isoprotenerol (0.5 to 1.5 microg/min; n=10), and pacing (in subjects with permanent pacemakers; n=11) increased heart rate but had differential effects on systolic blood pressure and pulse pressure. The increase in heart rate produced by isoprotenerol (18+/-3 bpm) and pacing (40 bpm) was associated with an increase in PWV measured using both systems (increases of 0.7+/-0.2 m/s and 0.9+/-0.2 m/s for SphygmoCor and Complior, respectively, during isoprotenerol and increases of 2.1+/-0.5 m/s and 1.1+/-0.2 m/s for SphygmoCor and Complior, respectively, during pacing, each P<0.001). Reanalysis of waveforms recorded from the Complior system using the foot-to-foot method produced similar values of PWV to those obtained with the SphygmoCor, confirming that the difference between these systems was attributable to the timing algorithm rather than other aspects of signal acquisition. Carotid-femoral PWV is critically dependent on the method used to determine propagation time, but this does not account for variation of PWV with heart rate.


Assuntos
Algoritmos , Artérias Carótidas/fisiopatologia , Artéria Femoral/fisiopatologia , Frequência Cardíaca , Pulso Arterial , Agonistas Adrenérgicos beta/administração & dosagem , Adulto , Idoso , Estimulação Cardíaca Artificial , Cardiologia/métodos , Feminino , Frequência Cardíaca/efeitos dos fármacos , Humanos , Isoproterenol/administração & dosagem , Masculino , Pessoa de Meia-Idade , Taquicardia/etiologia , Taquicardia/fisiopatologia , Fatores de Tempo
14.
Hypertension ; 44(1): 67-71, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15148292

RESUMO

Hypertension and type 2 diabetes are associated with increased aortic pulse wave velocity (PWV), a measure of aortic stiffness and a powerful risk factor for cardiovascular events. The association of hypertension with type 2 diabetes may obscure the degree to which diabetes rather than hypertension contributes to an elevated PWV. The objective of this study was to determine whether the presence of type 2 diabetes is associated with an elevated PWV compared with nondiabetic subjects matched for mean arterial blood pressure. PWV was determined by measuring carotid to femoral transit time using applanation tonometry in 186 subjects (104 women) with (n=93) and without (n=93) type 2 diabetes. Diabetic and nondiabetic subjects were matched for age and mean arterial pressure (to +/-5 years and 5 mm Hg, respectively). PWV was strongly correlated with age and mean arterial blood pressure (R=0.59 and 0.29 respectively, each P<0.0001). PWV increased significantly more with age in women with diabetes (slope of regression line+/-SE: 0.19+/-0.03 m x s(-1) x year(-1)) than in nondiabetic women (0.08+/-0.02 m x s(-1) x year(-1), P<0.01 for difference). In men, however, the age-related increase in PWV was similar in diabetic (0.15+/-0.03 m x s(-1) x year(-1)) and nondiabetic subjects (0.13+/-0.03 m. s(-1) x year(-1), P=NS). The interaction of diabetic status with age and with sex was significant (P=0.01). Type 2 diabetes is associated with a greater age-related stiffening of the aorta in women compared with men, and this is not explained by hypertension.


Assuntos
Aorta/fisiopatologia , Pressão Sanguínea/fisiologia , Diabetes Mellitus Tipo 2/fisiopatologia , Adulto , Idoso , Velocidade do Fluxo Sanguíneo , Elasticidade , Feminino , Humanos , Hipertensão , Masculino , Análise por Pareamento , Pessoa de Meia-Idade , Caracteres Sexuais , Resistência Vascular
15.
Hypertension ; 42(5): 915-8, 2003 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12975386

RESUMO

Aortic stiffness, as measured by carotid-femoral pulse wave velocity (PWV), is a powerful, independent predictor of vascular risk. PWV in muscular arteries is influenced by basal nitric oxide (NO) release. It is not known whether NO also influences carotid-femoral PWV. We examined the effects of an NO synthase inhibitor, NG-monomethyl-l-arginine (L-NMMA), on carotid-femoral PWV and aortic augmentation index (AIx, an indirect measure of arterial stiffness). To control for effects of L-NMMA on distending pressure, we used doses of norepinephrine and dobutamine that caused similar changes in mean arterial blood pressure (MAP). Healthy men (32 to 48 years old, n=8) were studied on 4 occasions and received, in random order, vehicle, L-NMMA (3 mg x kg(-1) by intravenous bolus followed by 3 mg x kg(-1) x h(-1)), norepinephrine (50 ng x kg(-1) x min(-1)), and dobutamine (2.5 to 10 microg x kg(-1) x min(-1)), each for 30 minutes. PWV and AIx were measured by carotid-femoral PWV and radial tonometry, respectively. L-NMMA and norepinephrine increased MAP by 7.8+/-1.7 and 9.7+/-2.1 mm Hg, respectively (each P<0.05 vs vehicle) and increased PWV by 0.7+/-0.2 and 1.0+/-0.3 m x s(-1) (each P<0.01 vs vehicle). Dobutamine, at doses that produced a similar increase in MAP (9.6+/-2.9 mm Hg), increased PWV by 0.8+/-0.2 m x s(-1) (P<0.01 vs vehicle). Changes in PWV caused by the 3 pressor agents were closely correlated with changes in MAP (R>0.99, P<0.0001). L-NMMA and norepinephrine increased AIx, but dobutamine decreased AIx (P<0.01 vs norepinephrine and L-NMMA). Effects of inhibition of basal NO release on carotid-femoral PWV can be explained by the change in MAP that this causes rather than any specific effect of NO inhibition within the aorta.


Assuntos
Artérias Carótidas/fisiologia , Artéria Femoral/fisiologia , Óxido Nítrico/antagonistas & inibidores , Adulto , Elasticidade , Inibidores Enzimáticos/farmacologia , Humanos , Masculino , Pessoa de Meia-Idade , Óxido Nítrico/biossíntese , Óxido Nítrico Sintase/antagonistas & inibidores , Fluxo Pulsátil/efeitos dos fármacos , ômega-N-Metilarginina/farmacologia
16.
Am J Hypertens ; 16(6): 467-72, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12799095

RESUMO

BACKGROUND: Indices of pressure wave reflection (RI(DVP)) and large artery stiffness (SI(DVP)) can be derived from the digital volume pulse (DVP). Indices obtained from the second derivative of the DVP have also been proposed to characterize vascular aging and effects of vasoactive drugs. METHODS: We compared RI(DVP) and SI(DVP) with the indices a/b, a/c, a/d, and a/e calculated from sequential peaks of the second derivative of the DVP in 124 healthy men. The DVP was obtained by measuring infrared light transmission through the finger. In 10 men measurements were obtained at baseline and during intravenous infusion of glyceryl trinitrate (GTN, 3 to 300 microg/min) and, on separate occasions, angiotensin II (AII, 75 to 300 microg/min) and saline vehicle. RESULTS: SI(DVP) was strongly associated with age (R = 0.63, P <.001) but little influenced by AII or GTN. RI(DVP) was weakly associated with age but showed a consistent dose-dependent increase during AII and a decrease during GTN. d/a was strongly associated with age (R = -0.66, P <.001), influenced by vasoactive drugs but did not change in a dose-dependent manner during GTN. Other second derivative indices were less strongly correlated with age and showed an inconsistent response to vasoactive drugs. Within subject standard deviations of SI(DVP) and d/a for measurements on different occasions were 2.1 and 5.4 "years of vascular aging" respectively. CONCLUSIONS: In healthy men, RI(DVP) may be a more reliable index of the effects of vasoactive drugs than d/a. SI(DVP) is similarly associated with age as is d/a, but less variable and may thus be a better index of vascular aging.


Assuntos
Envelhecimento/fisiologia , Pressão Sanguínea/efeitos dos fármacos , Nitroglicerina/administração & dosagem , Pletismografia/métodos , Vasodilatadores/administração & dosagem , Adulto , Idoso , Angiotensina II/administração & dosagem , Pressão Sanguínea/fisiologia , Determinação do Volume Sanguíneo/métodos , Determinação do Volume Sanguíneo/normas , Dedos , Humanos , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Pletismografia/normas , Reprodutibilidade dos Testes , Vasoconstritores/administração & dosagem
17.
Hypertension ; 41(5): 1016-20, 2003 May.
Artigo em Inglês | MEDLINE | ID: mdl-12695415

RESUMO

Synthesis of the aortic pressure waveform by application of a transfer function to the radial pulse allows the estimation of aortic systolic blood pressure and aortic augmentation index, an index of pressure wave reflection derived from the early systolic component of the waveform. The accuracy of this approach for determining the aortic augmentation index has been questioned, however, and it may be possible to derive similar information without using a transfer function. We compared aortic systolic blood pressure and the aortic augmentation index obtained from carotid and radial arteries with the use of transfer functions. We examined the correlation between the aortic augmentation index and a radial augmentation index obtained without use of a transfer function. Arterial tonometry (Sphygmocor) was performed in 84 subjects including healthy volunteers (n=30), subjects with essential hypertension (n=30), and patients with coronary artery disease (n=24). Effects of nitroglycerine and norepinephrine on aortic and radial augmentation index were examined in 12 healthy volunteers. Values of aortic systolic pressure obtained from radial and carotid arteries by using transfer functions were in acceptable agreement (R=0.98, difference=-0.9+/-4.6 mm Hg; mean+/-SD, n=84), but those of aortic augmentation index differed especially in control subjects (R=0.47, difference=-3.8+/-12.4%). Aortic augmentation index was, however, closely correlated with radial augmentation index (R=0.96, n=84). Nitroglycerine and norepinephrine produced parallel changes in the aortic and radial augmentation index. Our findings question the use of a transfer function to obtain the aortic augmentation index but suggest that similar information on central pressure wave reflection can be obtained directly from the radial pulse.


Assuntos
Fluxo Pulsátil/fisiologia , Pulso Arterial , Adulto , Idoso , Aorta/patologia , Aorta/fisiopatologia , Pressão Sanguínea/efeitos dos fármacos , Pressão Sanguínea/fisiologia , Artérias Carótidas/fisiologia , Artérias Carótidas/fisiopatologia , Doença da Artéria Coronariana/fisiopatologia , Humanos , Hipertensão/fisiopatologia , Pessoa de Meia-Idade , Nitroglicerina/administração & dosagem , Norepinefrina/administração & dosagem , Fluxo Pulsátil/efeitos dos fármacos , Artéria Radial/fisiologia , Artéria Radial/fisiopatologia , Sístole
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...